Average modelling of a voltage source inverter with dead-time in a synchronous reference frame

Voltage source inverters are an integral part of renewable power sources and smart grid systems. Computationally efficient and fairly accurate models for the voltage source inverter are required to carry out extensive simulation studies on complex power networks. Accuracy requires that the effect of dead-time be incorporated in the inverter model. The dead-time is essentially a short delay introduced between the gating pulses to the complementary switches in an inverter leg for the safety of power devices. As the modern voltage source inverters switch at fairly high frequencies, the dead-time significantly influences the output fundamental voltage. Dead-time also causes low-frequency harmonic distortion and is hence important from a power quality perspective. This paper studies the dead-time effect in a synchronous dq reference frame, since dynamic studies and controller design are typically carried out in this frame of reference. For the sake of computational efficiency, average models are derived, incorporating the dead-time effect, in both RYB and dq reference frames. The average models are shown to consume less computation time than their corresponding switching models, the accuracies of the models being comparable. The proposed average synchronous reference frame model, including effect of dead-time, is validated through experimental results.

[1]  R. Datta,et al.  Direct power control of grid-connected wound rotor induction machine without rotor position sensors , 2001 .

[2]  Osama A. Mohammed,et al.  Reactive power compensation in hybrid AC/DC Networks for Smart Grid applications , 2012, 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe).

[3]  E. Ortjohann,et al.  A general architecture for modular smart inverters , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[4]  D. Boroyevich,et al.  Development of a new voltage source inverter (VSI) average model including low frequency harmonics , 2010, 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[5]  Mario A. Herran,et al.  Adaptive Dead-Time Compensation for Grid-Connected PWM Inverters of Single-Stage PV Systems , 2013, IEEE Transactions on Power Electronics.

[6]  Raja Ayyanar,et al.  Dead time effect in two-level space vector PWM voltage source inverters with large current ripple , 2011, 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[7]  Qiang Gao,et al.  Mixed PWM for Dead-Time Elimination and Compensation in a Grid-Tied Inverter , 2011, IEEE Transactions on Industrial Electronics.

[8]  Marcelo Godoy Simões,et al.  A Multifunctional Single-Phase Voltage Source Inverter in Perspective of the Smart Grid Initiative , 2009, 2009 IEEE Industry Applications Society Annual Meeting.

[9]  G. Narayanan,et al.  Vector control of three-phase AC/DC front-end converter , 2008 .

[10]  Yoshihiro Murai,et al.  Waveform Distortion and Correction Circuit for PWM Inverters with Switching Lag-Times , 1987, IEEE Transactions on Industry Applications.

[11]  Hyun-Soo Kim,et al.  On-line dead-time compensation method based on time delay control , 2003, IEEE Trans. Control. Syst. Technol..

[12]  P. Kundur,et al.  Power system stability and control , 1994 .

[13]  Tapan K. Saha,et al.  Effect of wind farms with doubly fed induction generators on small-signal stability — A case study on Australian equivalent system , 2011, 2011 IEEE PES Innovative Smart Grid Technologies.

[14]  R.S. Colby,et al.  Simplified model and corrective measures for induction motor instability caused by PWM inverter blanking time , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.