Analysis of Convergence Characteristics of Average Method Regulated by ISO 9869-1 for Evaluating In Situ Thermal Resistance and Thermal Transmittance of Opaque Exterior Walls

In the last few decades, an average method which is regulated by ISO 9869-1 has been used to evaluate the in situ thermal transmittance (U-value) and thermal resistance (R-value) of building envelopes obtained from onsite measurements and to verify the validity of newly proposed methods. Nevertheless, only a few studies have investigated the test duration required to obtain reliable results using this method and the convergence characteristics of the results. This study aims to evaluate the convergence characteristics of the in situ values analyzed using the average method. The criteria for determining convergence (i.e., end of the test) using the average method are very strict, mainly because of the third condition, which compares the deviation of two values derived from the first and last periods of the same duration. To shorten the test duration, environmental variables should be kept constant throughout the test or an appropriate period should be selected. The convergence of the in situ U-value and R-value is affected more by the length of the test duration than by the temperature difference if the test environment meets literature-recommended conditions. Furthermore, there is no difference between the use of the U-value and R-value in determining the end of the test.

[1]  Dias Haralambopoulos,et al.  Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography , 1998 .

[2]  Constantinos A. Balaras,et al.  Infrared thermography for building diagnostics , 2002 .

[3]  I. Guerrero,et al.  Thermographic survey of two rural buildings in Spain , 2004 .

[4]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[5]  Targo Kalamees,et al.  Air tightness and air leakages of new lightweight single-family detached houses in Estonia , 2007 .

[6]  Luisa F. Cabeza,et al.  Experimental study on the performance of insulation materials in Mediterranean construction , 2010 .

[7]  Rossano Albatici,et al.  Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site , 2010 .

[8]  Roberto Ricciu,et al.  Comparing different approaches to in situ measurement of building components thermal resistance , 2011 .

[9]  Soteris A. Kalogirou,et al.  Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes , 2011 .

[10]  Giuliano Dall'O',et al.  Infrared Screening of Residential Buildings for Energy Audit Purposes: Results of a Field Test , 2013 .

[11]  John Counsell,et al.  Energy efficiency is more than skin deep: Improving construction quality control in new-build housing using thermography , 2013 .

[12]  Stefano Sfarra,et al.  Quantitative thermography for the estimation of the U-value: state of the art and a case study , 2014 .

[13]  Luai M. Al-Hadhrami,et al.  In situ measurement of thermal transmittance and thermal resistance of hollow reinforced precast concrete walls , 2014 .

[14]  Tadj Oreszczyn,et al.  Inferring the thermal resistance and effective thermal mass of a wall using frequent temperature and heat flux measurements , 2014 .

[15]  Giorgio Baldinelli,et al.  Evaluating in situ thermal transmittance of green buildings masonries—A case study , 2014 .

[16]  Elvira Ianniello,et al.  U-value in situ measurement for energy diagnosis of existing buildings , 2015 .

[17]  Claudia Guattari,et al.  In Situ Thermal Transmittance Measurements for Investigating Differences between Wall Models and Actual Building Performance , 2015 .

[18]  Michela Chiogna,et al.  A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance , 2015 .

[19]  Dario Ambrosini,et al.  A comparison between thermographic and flow-meter methods for the evaluation of thermal transmittance of different wall constructions , 2015 .

[20]  An-Heleen Deconinck,et al.  Comparison of characterisation methods determining the thermal resistance of building components from onsite measurements , 2016 .

[21]  John Currie,et al.  A longitudinal building fabric and energy performance analysis of two homes built to different energy principles , 2016 .

[22]  Myeong Jin Ko,et al.  Comparison of Various Analysis Methods Based on Heat Flowmeters and Infrared Thermography Measurements for the Evaluation of the In Situ Thermal Transmittance of Opaque Exterior Walls , 2017 .

[23]  Phillip Biddulph,et al.  nferring the thermal resistance and effective thermal mass istribution of a wall from in situ measurements to characterise heat ransfer at both the interior and exterior surfaces , 2016 .

[24]  Raul Tempone,et al.  Bayesian inferences of the thermal properties of a wall using temperature and heat flux measurements , 2016, 1608.03855.

[25]  Marta Gangolells,et al.  In situ measurement of façades with a low U-value: Avoiding deviations , 2018, Energy and Buildings.

[26]  Marta Gangolells,et al.  Review of criteria for determining HFM minimum test duration , 2018, Energy and Buildings.