A second‐order standard addition method with application to calibration of a kinetics–spectroscopic sensor for quantitation of trichloroethylene

Presented here is an algorithm for analysis of second order data by the method of standard additions. The method of standard additions is applicable when matrix effects make traditional calibration unreliable. The algorithm employs a generalized eigenproblem to mathematically separate the instrument response of the analyte from the instrument response of any interfering species. A scheme for determining the eigenvectors (and hence the concentration estimate) that uniquely correspond to the analyte of interest is given. These eigenvectors can readily be distinguished from any eigenvector that corresponds to the spectrum of the interferents or both the interferents and analyte. The stability of the estimated analyte concentration is verified by Monte Carlo simulations. The algorithm is applied to the analysis of trichloroethylene in samples that have matrix effects caused by an interaction with chloroform.

[1]  Bruce R. Kowalski,et al.  The Generalized Standard Addition Method. , 1979 .

[2]  Bruce R. Kowalski,et al.  Tensorial calibration: I. First‐order calibration , 1988 .

[3]  B. Everitt,et al.  Three-Mode Principal Component Analysis. , 1986 .

[4]  B. Kowalski,et al.  Tensorial resolution: A direct trilinear decomposition , 1990 .

[5]  L. G. Blackwood Factor Analysis in Chemistry (2nd Ed.) , 1994 .

[6]  Bruce R. Kowalski,et al.  Tensorial calibration: II. Second‐order calibration , 1988 .

[7]  Bruce R. Kowalski,et al.  An improved algorithm for the generalized rank annihilation method , 1989 .

[8]  G. Kateman,et al.  Expert systems for multivariate calibration, trendsetters for the wide-spread use of chemometrics , 1992 .

[9]  Gerrit Kateman,et al.  Generalized rank annihilation method. III: Practical implementation , 1994 .

[10]  G. Kateman,et al.  Multicomponent self-modelling curve resolution in high-performance liquid chromatography by iterative target transformation analysis , 1985 .

[11]  Edmund R. Malinowski,et al.  Window factor analysis: Theoretical derivation and application to flow injection analysis data , 1992 .

[12]  B. Kowalski,et al.  Effect of random experimental error on the generalized standard addition method , 1984 .

[13]  B. Kowalski,et al.  Advances in second‐order calibration , 1993 .

[14]  B. Kowalski,et al.  Theory of analytical chemistry , 1994 .

[15]  Bruce R. Kowalski,et al.  Multicomponent Determination of Chlorinated Hydrocarbons Using a Reaction-Based Chemical Sensor. 1. Multivariate Calibration of Fujiwara Reaction Products , 1994 .

[16]  S. Wold,et al.  Residual bilinearization. Part 1: Theory and algorithms , 1990 .