Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status

Electrocardiogram (ECG) is a standard type of monitoring in intensive care medicine. Several studies suggest that changes in ECG morphology may reflect changes in volume status. The “Brody effect”, a theoretical analysis of left ventricular (LV) chamber size influence on QRS-wave amplitude, is the key element of this phenomenon. It is characterised by an increase in QRS-wave amplitude that is induced by an increase in ventricular preload. This study investigated the influence of changes in intravascular volume status on respiratory variations of QRS-wave amplitudes (ΔECG) compared with respiratory pulse pressure variations (ΔPP), considered as a reference standard. In 17 pigs, ECG and arterial pressure were recorded. QRS-wave amplitude was measured from the Biopac recording to ensure that in all animals ECG electrodes were always at the same location. Maximal QRS amplitude (ECGmax) and minimal QRS amplitude (ECGmin) were determined over one respiratory cycle. ΔECG was calculated as 100 × [(ECGmax − ECGmin)/(ECGmax + ECGmin)/2]. ΔECG and ΔPP were simultaneously recorded. Measurements were performed at different time points: during normovolemic conditions, after haemorrhage (25 mL/kg), and following re-transfusion (25 mL/kg) with constant tidal volume (10 mL/kg) and respiration rate (15 breath/min). At baseline, ΔPP and ΔECG were both <12 %. ΔPP were significantly correlated with ΔECG (r2 = 0.89, p < 0.001). Volume loss induced by haemorrhage increased significantly ΔPP and ΔECG. Moreover, during this state, ΔPP were significantly correlated with ΔECG (r2 = 0.86, p < 0.001). Re-transfusion significantly decreased ΔPP and ΔECG, and ΔPP were significantly correlated with ΔECG (r2 = 0.90, p < 0.001). The observed correlations between ΔPP and ΔECG at each time point of the study suggest that ΔECG is a reliable parameter to estimate the changes in intravascular volume status and provide experimental confirmation of the “Brody effect.”

[1]  Y. Mahjoub,et al.  Respiratory variations of R-wave amplitude in lead II are correlated with stroke volume variations evaluated by transesophageal Doppler echocardiography. , 2012, Journal of cardiothoracic and vascular anesthesia.

[2]  K. Bendjelid,et al.  Primary aortoenteric fistula: should enhanced computed tomography be considered in the diagnostic work-up? , 2005, Anesthesia and analgesia.

[3]  Karim Bendjelid,et al.  Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients , 2007, Intensive Care Medicine.

[4]  D Young,et al.  Clinical trials of monitoring in anaesthesia, critical care and acute ward care: a review. , 2006, British journal of anaesthesia.

[5]  P. Heidenreich,et al.  The diagnosis of pericardial effusion and cardiac tamponade by 12-lead ECG. A technology assessment. , 1996, Chest.

[6]  V. Froelicher,et al.  The relationship between exercise-induced R wave amplitude changes and QRS vector loops. , 1981, Journal of electrocardiology.

[7]  Changes in electrocardiographic morphology reflect instantaneous changes in left ventricular volume and output in cardiac surgery patients. , 1995, The American journal of cardiology.

[8]  E. Michelson,et al.  Intramyocardial Conduction: A Major Determinant of R‐wave Amplitude During Acute Myocardial Ischemia , 1982, Circulation.

[9]  L. Beydon,et al.  Changes in R-Wave amplitude in DII lead is less sensitive than pulse pressure variation to detect changes in stroke volume after fluid challenge in ICU patients postoperatively to cardiac surgery , 2010, Journal of Clinical Monitoring and Computing.

[10]  J. Tyberg,et al.  Reduction in ventricular endocardial and epicardial potentials during acute increments in left ventricular dimensions. , 1979, American heart journal.

[11]  F. Michard,et al.  Volume Management Using Dynamic Parameters , 2005 .

[12]  T. Ryan,et al.  Increase in R-wave amplitude during transient epicardial injury (Prinzmetal type). , 1980, Journal of electrocardiology.

[13]  E. Michelson,et al.  R-wave amplitude responses to rapid atrial pacing: a marker for myocardial ischemia. , 1984, American heart journal.

[14]  Hermann Bondi,et al.  The good, the bad and the ugly , 1988, Nature.

[15]  J. Teboul,et al.  Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. , 2001, Chest.

[16]  M. Cannesson,et al.  Relations Between Respiratory Changes in R-Wave Amplitude and Arterial Pulse Pressure in Mechanically Ventilated Patients , 2010, Journal of Clinical Monitoring and Computing.

[17]  D. Brody A Theoretical Analysis of Intracavitary Blood Mass Influence on the Heart‐Lead Relationship , 1956, Circulation research.

[18]  K. Bendjelid The pulse oximetry plethysmographic curve revisited , 2008, Current opinion in critical care.

[19]  Karim Bendjelid,et al.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care , 2003, Intensive Care Medicine.

[20]  Y Lecarpentier,et al.  Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. , 1999, American journal of respiratory and critical care medicine.

[21]  K. Bendjelid,et al.  Pulse pressure variation, stroke volume variation and dynamic arterial elastance , 2011, Critical care.

[22]  Atul Wad,et al.  Technology assessment , 1984 .

[23]  F. Michard Volume management using dynamic parameters: the good, the bad, and the ugly. , 2005, Chest.

[24]  J. Teboul,et al.  The respiratory variation in inferior vena cava diameter as a guide to fluid therapy , 2004, Intensive Care Medicine.