Spherical-coordinate scanning confocal laser microscope

We present the design, construction, and characterization of a spherical-coordinate scanning, reflection-mode confocal laser microscope (SCSLM). Two system designs are presented, namely a conventional bulk optics object-scanning design and a preliminary optical-fiber-based two-axis optics/one-axis object scanning version. The bulk-optics design is characterized with respect to its optical sectioning property. Sample 3-D images acquired using the SCSLM are also presented, including a reconstruction of an ex vivo pig's cornea. The bulk optics design offers a higher light throughput, but it cannot be easily miniaturized for future integration in a microsurgical robot design. The fiber-based design has a reduced SNR but can be potentially made lightweight and small enough to be integrated as the imaging subsystem of a microsurgical robot.

[1]  T Wilson,et al.  Confocal scanning optical microscope using single-mode fiber for signal detection. , 1991, Applied optics.

[2]  Colin J. R. Sheppard,et al.  Fibre-optical confocal scanning interference microscopy , 1993 .

[3]  R. Webb,et al.  Confocal scanning laser ophthalmoscope. , 1987, Applied optics.

[4]  J. W. Warnicki,et al.  Corneal topography , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  T Dabbs,et al.  Fiber-optic confocal microscope: FOCON. , 1992, Applied optics.

[6]  B R Masters,et al.  Real-time scanning slit confocal microscopy of the in vivo human cornea. , 1994, Applied optics.

[7]  C J Koester,et al.  Clinical microscopy of the cornea utilizing optical sectioning and a high-numerical-aperture objective. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[8]  B R Masters,et al.  Three-dimensional reconstruction of the rabbit cornea by confocal scanning optical microscopy and volume rendering. , 1990, Applied optics.

[9]  Lynette A. Jones,et al.  A Teleoperated Microsurgical Robot and Associated Virtual Environment for Eye Surgery , 1993, Presence: Teleoperators & Virtual Environments.

[10]  S D Klyce,et al.  Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy. , 1984, Investigative ophthalmology & visual science.

[11]  T Wilson,et al.  Size of the detector in confocal imaging systems. , 1987, Optics letters.

[12]  A. Gmitro,et al.  Confocal microscopy through a fiber-optic imaging bundle. , 1993, Optics letters.

[13]  Gordon S. Kino,et al.  Scanned optical fiber confocal microscope , 1994, Electronic Imaging.