Technology in Rehabilitation: Comparing Personalised and Global Classification Methodologies in Evaluating the Squat Exercise with Wearable IMUs.

BACKGROUND The barbell squat is a popularly used lower limb rehabilitation exercise. It is also an integral exercise in injury risk screening protocols. To date athlete/patient technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete/patient technique. However, it is not yet known if global classification techniques are effective in identifying naturally occurring, minor deviations in barbell squat technique. OBJECTIVES The aims of this study were to: (a) determine if in combination or in isolation, IMUs positioned on the lumbar spine, thigh and shank are capable of distinguishing between acceptable and aberrant barbell squat technique; (b) determine the capabilities of an IMU system at identifying specific natural deviations from acceptable barbell squat technique; and (c) compare a personalised (N=1) classifier to a global classifier in identifying the above. METHODS Fifty-five healthy volunteers (37 males, 18 females, age = 24.21 +/- 5.25 years, height = 1.75 +/- 0.1 m, body mass = 75.09 +/- 13.56 kg) participated in the study. All participants performed a barbell squat 3-repetition maximum max strength test. IMUs were positioned on participants' lumbar spine, both shanks and both thighs; these were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the barbell squat exercise. Technique was assessed and labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled IMU data. These features were used to train and evaluate both global and personalised random forests classifiers. RESULTS Global classification techniques produced poor accuracy (AC), sensitivity (SE) and specificity (SP) scores in binary classification even with a 5 IMU set-up in both binary (AC: 64%, SE: 70%, SP: 28%) and multi-class classification (AC: 59%, SE: 24%, SP: 84%). However, utilising personalised classification techniques even with a single IMU positioned on the left thigh produced good binary classification scores (AC: 81%, SE: 81%, SP: 84%) and moderate-to-good multi-class scores (AC: 69%, SE: 70%, SP: 89%). CONCLUSIONS There are a number of challenges in developing global classification exercise technique evaluation systems for rehabilitation exercises such as the barbell squat. Building large, balanced data sets to train such systems is difficult and time intensive. Minor, naturally occurring deviations may not be detected utilising global classification approaches. Personalised classification approaches allow for higher accuracy and greater system efficiency for end-users in detecting naturally occurring barbell squat technique deviations. Applying this approach also allows for a single-IMU set up to achieve similar accuracy to a multi-IMU setup, which reduces total system cost and maximises system usability.

[1]  Gernot Bahle,et al.  What Can an Arm Holster Worn Smart Phone Do for Activity Recognition? , 2011, 2011 15th Annual International Symposium on Wearable Computers.

[2]  Vincent Bonnet,et al.  Real-time Estimate of Body Kinematics During a Planar Squat Task Using a Single Inertial Measurement Unit , 2013, IEEE Transactions on Biomedical Engineering.

[3]  Brian Caulfield,et al.  Evaluating performance of the lunge exercise with multiple and individual inertial measurement units , 2016, PervasiveHealth.

[4]  Hugo Fuks,et al.  Qualitative activity recognition of weight lifting exercises , 2013, AH.

[5]  Alberto Leardini,et al.  Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis , 2014, Journal of NeuroEngineering and Rehabilitation.

[6]  Takeo Kanade,et al.  Multi-label classification for the analysis of human motion quality , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Leo Breiman,et al.  Random Forests , 2001, Machine Learning.

[8]  Kristof Van Laerhoven,et al.  myHealthAssistant: a phone-based body sensor network that captures the wearer's exercises throughout the day , 2011, BODYNETS.

[9]  Peter Kokol,et al.  Exercise repetition detection for resistance training based on smartphones , 2012, Personal and Ubiquitous Computing.

[10]  Noel E. O'Connor,et al.  Automatically detecting asymmetric running using time and frequency domain features , 2015, 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN).

[11]  Darragh F Whelan,et al.  Technology in Rehabilitation: Evaluating the Single Leg Squat Exercise with Wearable Inertial Measurement Units. , 2016, Methods of information in medicine.

[12]  Brian Caulfield,et al.  Rehabilitation exercise assessment using inertial sensors: a cross-sectional analytical study , 2014, Journal of NeuroEngineering and Rehabilitation.

[13]  Ruzena Bajcsy,et al.  Recognizing the intensity of strength training exercises with wearable sensors , 2015, J. Biomed. Informatics.

[14]  A. J. Jerri The Shannon sampling theorem—Its various extensions and applications: A tutorial review , 1977, Proceedings of the IEEE.

[15]  Tadayoshi Fushiki,et al.  Estimation of prediction error by using K-fold cross-validation , 2011, Stat. Comput..

[16]  Noel E. O'Connor,et al.  Automatic Activity Classification and Movement Assessment During a Sports Training Session Using Wearable Inertial Sensors , 2014, 2014 11th International Conference on Wearable and Implantable Body Sensor Networks.

[17]  Brian Caulfield,et al.  Evaluating Performance of the Single Leg Squat Exercise with a Single Inertial Measurement Unit , 2015, REHAB.

[18]  C. Mazzà,et al.  A least-squares identification algorithm for estimating squat exercise mechanics using a single inertial measurement unit. , 2012, Journal of biomechanics.

[19]  M. Tahar Kechadi,et al.  Leveraging IMU data for accurate exercise performance classification and musculoskeletal injury risk screening , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[20]  Dennis Brandborg Nielsen,et al.  Forward lunge knee biomechanics before and after partial meniscectomy. , 2015, The Knee.

[21]  Moh H. Malek,et al.  NSCA's essentials of personal training , 2012 .

[22]  E. B. George,et al.  Fractals and the analysis of growth paths , 1985, Bulletin of mathematical biology.

[23]  David Whiteside,et al.  Grading the Functional Movement Screen: A Comparison of Manual (Real-Time) and Objective Methods , 2016, Journal of strength and conditioning research.

[24]  Lee Burton,et al.  Pre-participation screening: the use of fundamental movements as an assessment of function - part 1. , 2006, North American journal of sports physical therapy : NAJSPT.

[25]  B Bonnechère,et al.  Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry. , 2014, Gait & posture.

[26]  Seetha Hari,et al.  Learning From Imbalanced Data , 2019, Advances in Computer and Electrical Engineering.

[27]  Sotiris B. Kotsiantis,et al.  Machine learning: a review of classification and combining techniques , 2006, Artificial Intelligence Review.

[28]  Brian Caulfield,et al.  Gyroscope-based assessment of temporal gait parameters during treadmill walking and running , 2012 .

[29]  Dan Morris,et al.  RecoFit: using a wearable sensor to find, recognize, and count repetitive exercises , 2014, CHI.

[30]  Nitesh V. Chawla,et al.  Data Mining for Imbalanced Datasets: An Overview , 2005, The Data Mining and Knowledge Discovery Handbook.

[31]  Mike Y. Chen,et al.  Tracking Free-Weight Exercises , 2007, UbiComp.

[32]  Sebastian Madgwick,et al.  Estimation of IMU and MARG orientation using a gradient descent algorithm , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[33]  Toshiyo Tamura,et al.  Measurement and Estimation of 3D Orientation using Magnetic and Inertial Sensors , 2015 .

[34]  A. J. Jerri Correction to "The Shannon sampling theorem—Its various extensions and applications: A tutorial review" , 1979 .

[35]  Matteo Cesana,et al.  The Virtual Trainer: Supervising Movements Through a Wearable Wireless Sensor Network , 2009, 2009 6th IEEE Annual Communications Society Conference on Sensor, Mesh and Ad Hoc Communications and Networks Workshops.

[36]  Kostas Karpouzis,et al.  Emerging Artificial Intelligence Applications in Computer Engineering - Real Word AI Systems with Applications in eHealth, HCI, Information Retrieval and Pervasive Technologies , 2007, Emerging Artificial Intelligence Applications in Computer Engineering.

[37]  Brian Caulfield,et al.  Evaluating squat performance with a single inertial measurement unit , 2015, 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN).