Wear Simulation of Alumina‐on‐Alumina Prosthetic Hip Joints Using a Multidirectional Motion Pin‐on‐Disk Device

The wear of a state-of-the-art implant alumina against itself was studied with a circularly translating pin-on-disk (CTPOD) device, a wear simulator for prosthetic hip joint materials. The direction of sliding changed continually relative to the pin, preventing erroneous uniaxial grooving typical of ordinary pin-on-disk devices. The dominating wear mechanism was mild abrasion manifested as a relieflike surface, which agreed with clinical findings. The wear factor ranged from 1 × 10−8 to 6 × 10−8 mm3/(N·m). The CTPOD device, validated earlier for ultrahigh molecular weight polyethylene, was shown to be the first simple wear test device to produce wear similar to that known to occur clinically in alumina-on-alumina total hip prostheses.

[1]  V. Saikko,et al.  Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. , 2001, Journal of biomedical materials research.

[2]  A Unsworth,et al.  Wear in Retrieved Charnley Acetabular Sockets , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  C. Piconi,et al.  Analysis of a failed alumina THR ball head. , 1999, Biomaterials.

[4]  V. Saikko,et al.  A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. , 1998, Journal of biomedical materials research.

[5]  V. Saikko,et al.  Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. , 2001, Biomaterials.

[6]  J Fisher,et al.  Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions , 2001, Journal of materials science. Materials in medicine.

[7]  A Walter,et al.  On the material and the tribology of alumina-alumina couplings for hip joint prostheses. , 1992, Clinical orthopaedics and related research.

[8]  Olof Calonius,et al.  Force track analysis of contemporary hip simulators. , 2003, Journal of biomechanics.

[9]  V. Saikko,et al.  Low wear and friction in alumina/alumina total hip joints: a hip simulator study. , 1998, Acta orthopaedica Scandinavica.

[10]  L. Sedel,et al.  Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties. , 1996, Journal of biomedical materials research.

[11]  E. Serra,et al.  Volumetric determination of the wear of ceramics for hip joints. , 2002, Biomaterials.

[12]  J D Mabrey,et al.  Comparison of UHMWPE particles in synovial fluid and tissues from failed THA. , 2001, Journal of biomedical materials research.

[13]  J. Dorlot,et al.  Long-term effects of alumina components in total hip prostheses. , 1992, Clinical orthopaedics and related research.

[14]  P. Revell,et al.  Biological reaction to debris in relation to joint prostheses , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  J. G. Andrews,et al.  A biomechanical investigation of the human hip. , 1978, Journal of biomechanics.