A Two-Species Finite Volume Scalar Model for Modeling the Diffusion of Poly(lactic-co-glycolic acid) into a Coronary Arterial Wall from a Single Half-Embedded Drug Eluting Stent Strut

This paper outlines the methodology and results for a two-species finite volume scalar computational drug transport model developed for simulating the mass transport of Poly(lacticco-glycolic acid (PLGA)) from a half-embedded single strut implanted in a coronary arterial vessel wall. The mathematical drug transport model incorporates the convection-diffusion equation in scalar form (dimensionless) with a two-species (free-drug and bound-drug) mass transport setup, including reversible equilibrium reaction source terms for the free and bound-drug states to account for the pharmaco-kinetic reactions in the arterial wall. The relative reaction rates of the added source terms control the interconversion of the drug between the free and bound-drug states. The model is solved by a 2D finite-volume method for discretizing and solving the free and bound drug transport equations with anisotropic vascular drug diffusivities. This model is an improvement over previously developed models using the finite-difference and finite element method. A dimensionless characteristic scaling pre-analysis was conducted a priori to evaluate the significance of implementing the reaction source terms in the transport equations. This paper reports the findings of an investigation of the interstitial flow profile into the arterial wall and the free and bound drug diffusion profiles with a parametric study of varying the polymer drug concentration (low and high), tortuosity, porosity, and Peclet and DamKöhler numbers over the course of 400 h (16.67 days). The results also reveal how a single species drug delivery model that neglects both a reversible binding reaction source term and the porosity and tortuosity of the arterial wall cannot accurately predict the distribution of both the free and bound drug.

[1]  Rodward L. Hewlin,et al.  Continuous Flow Separation of Red Blood Cells and Platelets in a Y-Microfluidic Channel Device with Saw-Tooth Profile Electrodes via Low Voltage Dielectrophoresis , 2023, Current issues in molecular biology.

[2]  Rodward L. Hewlin,et al.  Computational Assessment of Magnetic Nanoparticle Targeting Efficiency in a Simplified Circle of Willis Arterial Model , 2023, International journal of molecular sciences.

[3]  Rodward L. Hewlin,et al.  A 3-D Printed Optically Clear Rigid Diseased Carotid Bifurcation Arterial Mock Vessel Model for Particle Image Velocimetry Analysis in Pulsatile Flow , 2023, ASME Open Journal of Engineering.

[4]  Rodward L. Hewlin,et al.  A Time-Dependent Two Species Explicit Finite Difference Computational Model for Analyzing Diffusion in a Drug Eluting Stented Coronary Artery Wall: a Phase I Study , 2022, Volume 4: Biomedical and Biotechnology; Design, Systems, and Complexity.

[5]  D. Ficai,et al.  Recent Advances in Manufacturing Innovative Stents , 2020, Pharmaceutics.

[6]  Rodward L. Hewlin,et al.  Development of 3-D Printed Optically Clear Rigid Anatomical Vessels for Particle Image Velocimetry Analysis in Cardiovascular Flow , 2019, Volume 7: Fluids Engineering.

[7]  J. Beckman,et al.  Paclitaxel-Coated Balloons and Eluting Stents: Is There a Mortality Risk in Patients with Peripheral Artery Disease? , 2019, Circulation.

[8]  Rodward L Hewlin,et al.  Development of a Two-Way Coupled Eulerian–Lagrangian Computational Magnetic Nanoparticle Targeting Model for Pulsatile Flow in a Patient-Specific Diseased Left Carotid Bifurcation Artery , 2019, Cardiovascular engineering and technology.

[9]  Claire Conway,et al.  Coronary Stent Fracture: Clinical Evidence Vs. the Testing Paradigm , 2018, Cardiovascular engineering and technology.

[10]  P. K. Mandal,et al.  Modelling Time-dependent Release Kinetics in Stent-based Delivery , 2018 .

[11]  Rodward L Hewlin,et al.  Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: “A Preliminary Framework Analysis” , 2018, Cardiovascular engineering and technology.

[12]  P. K. Mandal,et al.  Computational Modelling of Three-phase Stent-based Delivery , 2017 .

[13]  Sarifuddin,et al.  Effect of Diffusivity on the Transport of Drug Eluted from Drug-Eluting Stent , 2016 .

[14]  Prashanta Kumar Mandal,et al.  An unsteady analysis of arterial drug transport from half-embedded drug-eluting stent , 2015, Appl. Math. Comput..

[15]  M. Leon,et al.  Mechanisms of tissue uptake and retention of paclitaxel-coated balloons: impact on neointimal proliferation and healing , 2014, Open Heart.

[16]  John P. Kizito,et al.  Comparison of Carotid Bifurcation Hemodynamics in Patient-Specific Geometries at Rest and During Exercise , 2013 .

[17]  R. Braatz,et al.  Modelling intravascular delivery from drug-eluting stents with biodurable coating: investigation of anisotropic vascular drug diffusivity and arterial drug distribution , 2012, Computer methods in biomechanics and biomedical engineering.

[18]  M. Horner,et al.  A Two-Species Drug Delivery Model is Required to Predict Deposition from Drug-Eluting Stents , 2010 .

[19]  Francesco Migliavacca,et al.  Drug release from coronary eluting stents: A multidomain approach. , 2010, Journal of biomechanics.

[20]  Michael T. Walsh,et al.  Demonstrating the Influence of Compression on Artery Wall Mass Transport , 2010, Annals of Biomedical Engineering.

[21]  A. Tzafriri,et al.  Diffusion‐limited binding explains binary dose response for local arterial and tumour drug delivery , 2009, Cell proliferation.

[22]  A. Tzafriri,et al.  Luminal flow patterns dictate arterial drug deposition in stent-based delivery. , 2009, Journal of controlled release : official journal of the Controlled Release Society.

[23]  G Dubini,et al.  Modelling drug elution from stents: effects of reversible binding in the vascular wall and degradable polymeric matrix , 2008, Computer methods in biomechanics and biomedical engineering.

[24]  Elazer R Edelman,et al.  Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution. , 2007, Journal of controlled release : official journal of the Controlled Release Society.

[25]  P. Serruys,et al.  Drug-Eluting Stent Update 2007: Part I: A Survey of Current and Future Generation Drug-Eluting Stents: Meaningful Advances or More of the Same? , 2007, Circulation.

[26]  P Zunino,et al.  Expansion and drug elution model of a coronary stent , 2007, Computer methods in biomechanics and biomedical engineering.

[27]  L. P. Tan,et al.  Controlled release of sirolimus from a multilayered PLGA stent matrix. , 2006, Biomaterials.

[28]  G. Stone,et al.  Drug-eluting stents in the treatment of intermediate lesions: pooled analysis from four randomized trials. , 2006, Journal of the American College of Cardiology.

[29]  E. Edelman,et al.  Local and systemic drug competition in drug-eluting stent tissue deposition properties. , 2005, Journal of controlled release : official journal of the Controlled Release Society.

[30]  Frank Litvack,et al.  The effect of variable dose and release kinetics on neointimal hyperplasia using a novel paclitaxel-eluting stent platform: the Paclitaxel In-Stent Controlled Elution Study (PISCES). , 2005, Journal of the American College of Cardiology.

[31]  P. Colombo,et al.  Interfacial biology of in-stent restenosis , 2005, Expert review of medical devices.

[32]  A. Tzafriri,et al.  Strut Position, Blood Flow, and Drug Deposition: Implications for Single and Overlapping Drug-Eluting Stents , 2005, Circulation.

[33]  J. Deux,et al.  Low Molecular Weight Fucoidan Prevents Neointimal Hyperplasia in Rabbit Iliac Artery In-Stent Restenosis Model , 2002, Arteriosclerosis, thrombosis, and vascular biology.

[34]  L. Kalachev,et al.  Numerical Simulation of Local Pharmacokinetics of a Drug after Intravascular Delivery with an Eluting Stent , 2002, Journal of drug targeting.

[35]  E. Edelman,et al.  Physiological Transport Forces Govern Drug Distribution for Stent-Based Delivery , 2001, Circulation.

[36]  Elazer R Edelman,et al.  Arterial heparin deposition: role of diffusion, convection, and extravascular space. , 1998, American journal of physiology. Heart and circulatory physiology.

[37]  R. Wilensky,et al.  Effect of atherosclerosis on transmural convection an arterial ultrastructure. Implications for local intravascular drug delivery. , 1997, Arteriosclerosis, thrombosis, and vascular biology.

[38]  E. Edelman,et al.  Computational simulations of local vascular heparin deposition and distribution. , 1996, The American journal of physiology.

[39]  B. Caleb,et al.  Binding and internalization of heparin by vascular smooth muscle cells , 1985, Journal of cellular physiology.

[40]  T. Higuchi MECHANISM OF SUSTAINED-ACTION MEDICATION. THEORETICAL ANALYSIS OF RATE OF RELEASE OF SOLID DRUGS DISPERSED IN SOLID MATRICES. , 1963, Journal of pharmaceutical sciences.

[41]  Ute Hoffmann,et al.  Drug Delivery Engineering Principles For Drug Therapy , 2016 .

[42]  Rodward L. Hewlin,et al.  Transient Cardiovascular Hemodynamics in a Patient-Specific Arterial System , 2015 .

[43]  A. Grodzinsky,et al.  The effect of aging and pressure on the specific hydraulic conductivity of the aortic wall. , 1996, Biorheology.