Recommendations on performance characteristics of diagnostic exposure meters: report of AAPM Diagnostic X-Ray Imaging Task Group No. 6.

Task Group 6 of the Diagnostic X-Ray Imaging Committee of the American Association of Physicists in Medicine (AAPM) was appointed to develop performance standards for diagnostic x-ray exposure meters. The recommendations as approved by the Diagnostic X-Ray Imaging Committee and the Science Council of the AAPM are delineated in this report and provide specifications on meter precision, calibration accuracy, calibration reference points, linearity, energy dependence, exposure rate dependence, leakage, amplification gain settings, directional dependence, the stem effect, constancy checks, and calibration intervals. The report summarizes recommendations for meters used in mammography, general purpose radiography including special procedures, computed tomography, and radiation safety surveys for x-ray radiography.

[1]  J. Boag The recombination correction for an ionisation chamber exposed to pulsed radiation in a 'swept beam' technique. I. Theory. , 1982, Physics in medicine and biology.

[2]  G. Barnes,et al.  Spectral dependence of glandular tissue dose in screen-film mammography. , 1991, Radiology.

[3]  Dai-ichi Nuclear Accident,et al.  The International Commission on Radiological Protection , 1963, Nature.

[4]  T. Villafana,et al.  Dosage evaluation in mammography. , 1984, Radiology.

[5]  R A Dickson,et al.  Assessment of scoliosis in children: low dose radiographic technique. , 1980, The British journal of radiology.

[6]  Division on Earth Health Effects of Exposure to Low Levels of Ionizing Radiation: BEIR V , 1990 .

[7]  B. Archer,et al.  Conceptus dose from two state-of-the-art CT scanners. , 1986, Radiology.

[8]  P. Almond Use of a Victoreen 500 electrometer to determine ionization chamber collection efficiencies. , 1981, Medical physics.

[9]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[10]  H. A. Peterson,et al.  Reduction of radiation exposure during radiography for scoliosis. , 1983, The Journal of bone and joint surgery. American volume.

[11]  B. Archer,et al.  On the measurement of half-value layer in film-screen mammography. , 1990, Medical physics.

[12]  D. Holmes,et al.  Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization. , 1986, Mayo Clinic proceedings.

[13]  D. Dance Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. , 1990, Physics in medicine and biology.

[14]  R. Gagne,et al.  A METHOD FOR DESCRIBING THE DOSES DELIVERED BY TRANSMISSION X‐RAY COMPUTED TOMOGRAPHY , 1981, Medical physics.

[15]  H. Venema,et al.  Filter materials for dose reduction in screen-film radiography. , 1986, Physics in medicine and biology.