A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond‐shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled into the tray. The collimator jaws of the linac were aligned such that the light field fell directly on the corners of the diamond. A radiation detection algorithm within the EPI software determined the extent of the radiation field. The light and radiation field congruence was evaluated by comparing the vertexes of the diamond reference structure to the detected radiation field. In addition, the digital jaw settings were recorded and later compared to the light field detected on the films and EPIs. Three linear accelerators were tracked for a period ranging from 2–8 months. Light radiation field congruence tests with films and EPIs were comparable, yielding a difference of less than 0.6 mm, well within the allowed 2‐mm tolerance. A disparity was observed in the magnitude of the detected light field. The X and Y dimensions of the light field measured with film differed by less than or equal to 1.4 mm from the digital collimator settings, whereas the values extracted from the EPIs differed by up to 2.5 mm. Based on these findings, EPIs were found to be a quick and reliable alternative to film for qualitative and relative analyses. PACS number(s): 87.53.Xd, 87.56.Fc, 87.53.Oq, 87.52.–g, 87.53.–j
[1]
Accurate measurement of the dynamic response of a scanning electronic portal imaging device.
,
2001,
Medical physics.
[2]
M van Herk,et al.
Radiation field edge detection in portal images.
,
1991,
Physics in medicine and biology.
[3]
A G Visser,et al.
Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device.
,
1999,
Medical physics.
[4]
S Shalev,et al.
Assessing radiation and light field congruence with a video based electronic portal imaging device.
,
1996,
Medical physics.
[5]
J. Palta,et al.
Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.
,
1994,
Medical physics.
[6]
K Leszczynski,et al.
A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device.
,
1999,
Medical physics.
[7]
M Partridge,et al.
IMRT verification with a camera-based electronic portal imaging system.
,
2000,
Physics in medicine and biology.