Doubly imprinted polymer nanofilm-modified electrochemical sensor for ultra-trace simultaneous analysis of glyphosate and glufosinate.

A rapid, selective, and sensitive double-template imprinted polymer nanofilm-modified pencil graphite electrode was fabricated for the simultaneous analysis of phosphorus-containing amino acid-type herbicides (glyphosate and glufosinate) in soil and human serum samples. Since both herbicides respond overlapped oxidation peaks and only glyphosate is prone to nitrosation, n-nitroso glyphosate and glufosinate were used as templates for obtaining the well-resolved quantitative differential pulse anodic stripping voltammetric peaks on the proposed sensor. Toward sensor fabrication, a nano-structured polymer film was first grown directly on the electrode via initial immobilization of gold nanoparticles at its surface. This was followed by linking of monomeric (N-methacryloyl-l-cysteine) molecules through S-Au bonds. Subsequently, these molecules were subjected to free radical polymerization, in the presence of templates, cross linker, initiator, and multiwalled carbon nanotubes as pre-polymer mixture. The modified sensor observed wide linear ranges (3.98-176.23 ng mL(-1) and 0.54-3.96 ng mL(-1)) of simultaneous analysis with detection limits as low as 0.35 and 0.19 ng mL(-1) (S/N=3) for glyphosate and glufosinate, respectively, in aqueous samples. The respective oxidation peak potentials of both analytes were found to be substantially apart by 265 mV. This enabled the simultaneous determination of one target in the presence of other, without any cross reactivity, interferences, and false-positives, in real samples.

[1]  A. Galal,et al.  Gold nanoparticles-coated poly(3,4-ethylene-dioxythiophene) for the selective determination of sub-nano concentrations of dopamine in presence of sodium dodecyl sulfate , 2012 .

[2]  N. Sugimoto,et al.  Molecularly-imprinted polymeric logic gates selective for predetermined chemical input species. , 2006, Chemical communications.

[3]  Shuvo Roy,et al.  Electrochemical detection and characterization of proteins. , 2006, Biosensors & bioelectronics.

[4]  J. Hollender,et al.  Ultratrace-level determination of glyphosate, aminomethylphosphonic acid and glufosinate in natural waters by solid-phase extraction followed by liquid chromatography–tandem mass spectrometry: performance tuning of derivatization, enrichment and detection , 2008, Analytical and bioanalytical chemistry.

[5]  D. Stocco,et al.  Roundup inhibits steroidogenesis by disrupting steroidogenic acute regulatory (StAR) protein expression. , 2000, Environmental health perspectives.

[6]  Jinghua Yu,et al.  Determination of glyphosate in foodstuff by one novel chemiluminescence-molecular imprinting sensor. , 2011, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[7]  C. Lucy,et al.  Determination of glyphosate using off-line ion exchange preconcentration and capillary electrophoresis-laser induced fluorescence detection. , 2007, Talanta.

[8]  Hiroyuki Otsuka,et al.  Determination of glyphosate, glyphosate metabolites, and glufosinate in human serum by gas chromatography-mass spectrometry. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[9]  Y. Lo,et al.  Simultaneous quantification of glyphosate, glufosinate, and their major metabolites in rice and soybean sprouts by gas chromatography with pulsed flame photometric detector. , 2004, Journal of agricultural and food chemistry.

[10]  M. Márquez,et al.  N-nitrosation of amines by NO2 and NO: a theoretical study. , 2007, The journal of physical chemistry. A.

[11]  P. Wieczorek,et al.  Determination of glyphosate and its metabolite aminomethylphosphonic acid in fruit juices using supported-liquid membrane preconcentration method with high-performance liquid chromatography and UV detection after derivatization with p-toluenesulphonyl chloride. , 2005, Journal of chromatography. A.

[12]  L Y Beaulieu,et al.  Measuring Thickness Changes in Thin Films Due to Chemical Reaction by Monitoring the Surface Roughness with In Situ Atomic Force Microscopy , 2002, Microscopy and Microanalysis.

[13]  R. Mehrabian,et al.  Functionalized Carbon Nanotubes with Gold Nanoparticles to Fabricate a Sensor for Hydrogen Peroxide Determination , 2012 .

[14]  E. Iwuoha,et al.  Amperometric nanobiosensor for quantitative determination of glyphosate and glufosinate residues in corn samples , 2009 .

[15]  Yalei Zhang,et al.  Removal of carbamazepine and clofibric acid from water using double templates–molecularly imprinted polymers , 2013, Environmental Science and Pollution Research.

[16]  L. Kubota,et al.  Experimental design employed to square wave voltammetry response optimization for the glyphosate determination , 2004 .

[17]  P. Wieczorek,et al.  Determination of glyphosate and aminomethylphosphonic acid in natural water using the capillary electrophoresis combined with enrichment step , 2005 .

[18]  N. Bénachour,et al.  Differential Effects of Glyphosate and Roundup on Human Placental Cells and Aromatase , 2009 .

[19]  Double imprinting in a single molecularly imprinted polymer format for the determination of ascorbic acid and dopamine , 2011 .

[20]  E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems , 1979 .

[21]  H. Kataoka,et al.  Simple and rapid determination of the herbicides glyphosate and glufosinate in river water, soil and carrot samples by gas chromatography with flame photometric detection , 1996 .

[22]  N. A. Hampson,et al.  Oxidations involving silver. V. The oxidation of primary aliphatic amines , 1969 .

[23]  Surong Mei,et al.  Preparation of mixed-templates molecularly imprinted polymers and investigation of the recognition ability for tetracycline antibiotics. , 2010, Biosensors & bioelectronics.

[24]  T. Guo,et al.  A dual-template imprinted capsule with remarkably enhanced catalytic activity for pesticide degradation and elimination simultaneously. , 2013, Chemical communications.

[25]  Xiaoming Zhao,et al.  Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column. , 2011, Journal of chromatography. A.

[26]  G. Hoerlein,et al.  Glufosinate (phosphinothricin), a natural amino acid with unexpected herbicidal properties. , 1994, Reviews of environmental contamination and toxicology.

[27]  K. Sreenivasan Molecularly imprinted polyacrylic acid containing multiple recognition sites for steroids , 2001 .

[28]  Lei Zhou,et al.  Fast and interference-free determination of glyphosate and glufosinate residues through electrophoresis in disposable microfluidic chips. , 2013, Journal of chromatography. A.

[29]  P. Sharma,et al.  Electrochemical sensor for folic acid based on a hyperbranched molecularly imprinted polymer-immobilized sol-gel-modified pencil graphite electrode , 2010 .

[30]  B. Penke,et al.  Functionalization of gold nanoparticles with amino acid, beta-amyloid peptides and fragment. , 2010, Colloids and surfaces. B, Biointerfaces.

[31]  H. Alemu,et al.  Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode , 2007 .

[32]  Jianping Li,et al.  A strategy for constructing sensitive and renewable molecularly imprinted electrochemical sensors for melamine detection. , 2011, Analytica chimica acta.

[33]  J. Startin,et al.  Analysis of glyphosate and glufosinate by capillary electrophoresis-mass spectrometry utilising a sheathless microelectrospray interface. , 2003, Journal of chromatography. A.

[34]  R. Suedee,et al.  Recognition Properties and Competitive Assays of a Dual Dopamine/Serotonin Selective Molecularly Imprinted Polymer , 2008, International journal of molecular sciences.

[35]  Bhim Bali Prasad,et al.  A dual-template imprinted polymer-modified carbon ceramic electrode for ultra trace simultaneous analysis of ascorbic acid and dopamine. , 2013, Biosensors & bioelectronics.

[36]  M. Wei,et al.  Simultaneous Determination of Glyphosate, Glufosinate, and Aminomethylphosphonic Acid by Capillary Electrophoresis After 9-Fluorenylmethyl Chloroformate Derivatization , 2005 .

[37]  Wei Gao,et al.  Voltammetric behavior and square-wave voltammetric determination of trepibutone at a pencil graphite electrode , 2005 .

[38]  C. Stalikas,et al.  Analytical methods to determine phosphonic and amino acid group-containing pesticides. , 2001, Journal of chromatography. A.

[39]  Huangxian Ju,et al.  Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer , 1999 .

[40]  Zhixiang Xu,et al.  Molecularly Imprinted Polymer as Sorbent for Solid-Phase Extraction Coupling to Gas Chromatography for the Simultaneous Determination of Trichlorfon and Monocrotophos Residues in Vegetables , 2013, Food Analytical Methods.

[41]  P. Hauser,et al.  Rapid and direct determination of glyphosate, glufosinate, and aminophosphonic acid by online preconcentration CE with contactless conductivity detection , 2010, Electrophoresis.

[42]  E. Scavetta,et al.  Glyphosate and glufosinate detection at electrogenerated NiAl-LDH thin films. , 2009, Analytica chimica acta.

[43]  I. Cernica,et al.  Self-assembly characteristics of gold nanoparticles in the presence of cysteine , 2009 .

[44]  H. A. Moye,et al.  A simplified high-performance liquid chromatographic residue procedure for the determination of glyphosate herbicide and (aminomethyl)phosphonic acid in fruits and vegetables employing postcolumn fluorogenic labeling. , 1983, Journal of agricultural and food chemistry.

[45]  Arturo J. Miranda-Ordieres,et al.  Electrochemical sensors based on molecularly imprinted polymers , 2004 .

[46]  Zhenyang Wang,et al.  Imprinting of Molecular Recognition Sites on Nanostructures and Its Applications in Chemosensors , 2008, Sensors.

[47]  Y. Hirose,et al.  Determination of the herbicide glyphosate and its metabolite in biological specimens by gas chromatography-mass spectrometry. A case of poisoning by roundup herbicide. , 2003, Journal of analytical toxicology.

[48]  W. Matthews,et al.  Analysis of glyphosate using capillary electrophoresis with indirect detection , 1996 .

[49]  A. Jenkins,et al.  Molecularly imprinted polymer sensors for pesticide and insecticide detection in water. , 2001, The Analyst.

[50]  C. Stalikas,et al.  Development of a method for the simultaneous determination of phosphoric and amino acid group containing pesticides by gas chromatography with mass-selective detection optimization of the derivatization procedure using an experimental design approach. , 2000, Journal of chromatography. A.

[51]  Junbai Li,et al.  Smart core/shell nanocomposites: intelligent polymers modified gold nanoparticles. , 2009, Advances in colloid and interface science.

[52]  T. Fujii,et al.  Alterations in the Response to Kainic Acid in Rats Exposed to Glufosinate Ammonium, a Herbicide, during Infantile Period. , 1996 .