Peri-implant Fractures Following Hook Plate Fixation for Unstable Distal Clavicle Fractures.

Clavicle hook plate is a common implant for treating distal clavicle fracture. Although high bone union rate and good functional outcome have been reported, so have several complications, such as osteolysis and fracture of the acromion, loss reduction, hook impingement, and rotator cuff tear. Peri-implant fracture over the medial side of the hook plate is a rare complication. Sporadic cases have been reported, and most of them have had no history of trauma. Between June 2015 and August 2018, 7 patients treated for distal clavicle fracture with a 3.5-mm locking compression hook plate with no history of trauma experienced peri-implant fracture of the medial clavicle. This complication occurred at a mean of 29 days. The incidence rate was 9.8%. Peri-implant fracture following hook plate fixation for distal clavicle fracture was not rare. Small hook angle, prolonged retention of the implant, an eccentric medial screw, high plate screw density, and small clavicle diameter may be risk factors for peri-implant fracture. Regarding treatment, 2 patients chose fracture revision with a distal clavicle locking plate and 5 patients chose conservative treatment. All patients achieved bone union at fracture sites. Surgical and conservative management of peri-implant fracture can achieve good functional outcome. [Orthopedics. 2020;43(x);xx-xx.].

[1]  Li-ning Zhang,et al.  Late function and complications of hook plate implantation for distal-third clavicle fractures : a retrospective study. , 2017, Acta orthopaedica Belgica.

[2]  N. Südkamp,et al.  Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures , 2017, Archives of Orthopaedic and Trauma Surgery.

[3]  Kuo-Chih Su,et al.  Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint , 2017, International Orthopaedics.

[4]  Kuo-Chih Su,et al.  Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study. , 2016, Artificial organs.

[5]  Yi-xin Chen,et al.  Anatomical Study of the Clavicles in a Chinese Population , 2016, BioMed research international.

[6]  Chien-Chou Pan,et al.  Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths , 2015, International Orthopaedics.

[7]  O. Al.,et al.  Locking or Non-locking Hook Plate in Treatment of Unstable Lateral Clavicle Fracture , 2015 .

[8]  Deye Song,et al.  Rare complication of clavicular hook plate: clavicle fracture at the medial end of the plate. , 2011, Journal of shoulder and elbow surgery.

[9]  M. Frankle,et al.  Results of surgical treatment for unstable distal clavicular fractures. , 2010, Journal of shoulder and elbow surgery.

[10]  Shan-Wei Yang,et al.  Acromion osteolysis and fracture after hook plate fixation for acromioclavicular joint dislocation: a case report. , 2010, Journal of shoulder and elbow surgery.

[11]  A. Agur,et al.  Subacromial morphometric assessment of the clavicle hook plate. , 2010, Injury.

[12]  S. Ghosh,et al.  Fixation Failure of the Clavicular Hook Plate: A Report of Three Cases , 2006, Journal of orthopaedic surgery.

[13]  B. Machani,et al.  Clavicular hook plate for lateral end fractures:- a prospective study. , 2006, Injury.

[14]  P. Hyvönen,et al.  Hook-plate fixation of unstable lateral clavicle fractures: A report on 63 patients , 2006, Acta orthopaedica.

[15]  J. Mahaluxmivala,et al.  Clavicular hook-plate: complications of retaining the implant. , 2005, Injury.

[16]  Dhanjoo N. Ghista,et al.  Design of Fracture Fixation Plate for Necessary and Sufficient Bone Stress Shielding , 2004 .

[17]  K. An,et al.  Torsional strength reduction due to cortical defects in bone , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.