Stability analysis and active damping for LLCL-filter based grid-connected inverters

A higher order passive power filter (LLCL-filter) for the grid-tied inverter is becoming attractive for the industrial applications due to the possibility to reduce the cost of the copper and the magnetic material. To avoid the well-known stability problems of the LLCL-filter it is requested to use either passive or active damping methods. This paper analyzes the stability when damping is required and when damping is not necessary considering sampling and transport delay. Basic LLCL resonance damping properties of different feedback states are also studied. Then an active damping method which is using the capacitor current feedback for LLCL-filter is introduced. Based on this method, a design procedure for the control method is given. Last, both simulation and experimental results are provided to validate the theoretical analysis of this paper.

[1]  Pekik Argo Dahono A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[2]  Timothy C. Green,et al.  Reducing passive filter sizes with tuned traps for distribution level power electronics , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[3]  Xinbo Ruan,et al.  Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.

[4]  Xinbo Ruan,et al.  Design of injected grid current regulator and capacitor-current-feedback active-damping for LCL-type grid-connected inverter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[5]  Xing Zhang,et al.  A novel control strategy of LCL-VSC based on notch concept , 2010, The 2nd International Symposium on Power Electronics for Distributed Generation Systems.

[6]  Frede Blaabjerg,et al.  Design-oriented analysis of resonance damping and harmonic compensation for LCL-filtered voltage source converters , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[7]  M. Liserre,et al.  Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.

[8]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[9]  Jun-ichi Itoh,et al.  Damping Control of Filter Resonance Focusing on Output Stage for Multi-Modular Matrix Converter , 2013 .

[10]  F. Blaabjerg,et al.  An LLCL Power Filter for Single-Phase Grid-Tied Inverter , 2012, IEEE Transactions on Power Electronics.

[11]  Xin Wang,et al.  Application of an LLCL filter on three-phase three-wire shunt active power filter , 2012, Intelec 2012.

[12]  M. Liserre,et al.  Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters , 2013, IEEE Transactions on Power Electronics.

[13]  Zhaoming Qian,et al.  A Robust Control Scheme for Grid-Connected Voltage-Source Inverters , 2011, IEEE Transactions on Industrial Electronics.

[14]  P. Rodriguez,et al.  Design of the LCL+trap filter for the two-level VSC installed in a large-scale wave power plant , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[15]  Frede Blaabjerg,et al.  Resonant-inductor-voltage-feedback active damping based control for grid-connected inverters with LLCL-filters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[16]  Poh Chiang Loh,et al.  Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[17]  Frede Blaabjerg,et al.  A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter , 2013, IEEE Transactions on Industrial Electronics.

[18]  Frede Blaabjerg,et al.  Step by step design of a high order power filter for three-phase three-wire grid-connected inverter in renewable energy system , 2013, 2013 4th IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[19]  F. Blaabjerg,et al.  A composite passive damping method of the LLCL-filter based grid-tied inverter , 2012, 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[20]  Steffan Hansen,et al.  Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.

[21]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[22]  Yu Zhang,et al.  Full Feedforward of Grid Voltage for Discrete State Feedback Controlled Grid-Connected Inverter With LCL Filter , 2012, IEEE Transactions on Power Electronics.

[23]  Vinod John,et al.  Filter Optimization for Grid Interactive Voltage Source Inverters , 2010, IEEE Transactions on Industrial Electronics.

[24]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[25]  Donald Grahame Holmes,et al.  Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[26]  Yan Zhou,et al.  Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[27]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[28]  Mat Syai'in,et al.  Steady‐state solutions of a voltage source converter with dq‐frame controllers by means of the time‐domain method , 2014 .

[29]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[30]  M. Liserre,et al.  Robustness analysis of active damping methods for an inverter connected to the grid with an LCL-filter , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[31]  M. Liserre,et al.  A stable three-phase LCL-filter based active rectifier without damping , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..