Stability analysis and active damping for LLCL-filter based grid-connected inverters
暂无分享,去创建一个
[1] Pekik Argo Dahono. A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).
[2] Timothy C. Green,et al. Reducing passive filter sizes with tuned traps for distribution level power electronics , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.
[3] Xinbo Ruan,et al. Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.
[4] Xinbo Ruan,et al. Design of injected grid current regulator and capacitor-current-feedback active-damping for LCL-type grid-connected inverter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).
[5] Xing Zhang,et al. A novel control strategy of LCL-VSC based on notch concept , 2010, The 2nd International Symposium on Power Electronics for Distributed Generation Systems.
[6] Frede Blaabjerg,et al. Design-oriented analysis of resonance damping and harmonic compensation for LCL-filtered voltage source converters , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).
[7] M. Liserre,et al. Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.
[8] D. G. Holmes,et al. Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.
[9] Jun-ichi Itoh,et al. Damping Control of Filter Resonance Focusing on Output Stage for Multi-Modular Matrix Converter , 2013 .
[10] F. Blaabjerg,et al. An LLCL Power Filter for Single-Phase Grid-Tied Inverter , 2012, IEEE Transactions on Power Electronics.
[11] Xin Wang,et al. Application of an LLCL filter on three-phase three-wire shunt active power filter , 2012, Intelec 2012.
[12] M. Liserre,et al. Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters , 2013, IEEE Transactions on Power Electronics.
[13] Zhaoming Qian,et al. A Robust Control Scheme for Grid-Connected Voltage-Source Inverters , 2011, IEEE Transactions on Industrial Electronics.
[14] P. Rodriguez,et al. Design of the LCL+trap filter for the two-level VSC installed in a large-scale wave power plant , 2013, 2013 IEEE Energy Conversion Congress and Exposition.
[15] Frede Blaabjerg,et al. Resonant-inductor-voltage-feedback active damping based control for grid-connected inverters with LLCL-filters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).
[16] Poh Chiang Loh,et al. Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.
[17] Frede Blaabjerg,et al. A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter , 2013, IEEE Transactions on Industrial Electronics.
[18] Frede Blaabjerg,et al. Step by step design of a high order power filter for three-phase three-wire grid-connected inverter in renewable energy system , 2013, 2013 4th IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).
[19] F. Blaabjerg,et al. A composite passive damping method of the LLCL-filter based grid-tied inverter , 2012, 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).
[20] Steffan Hansen,et al. Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.
[21] M. Liserre,et al. Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).
[22] Yu Zhang,et al. Full Feedforward of Grid Voltage for Discrete State Feedback Controlled Grid-Connected Inverter With LCL Filter , 2012, IEEE Transactions on Power Electronics.
[23] Vinod John,et al. Filter Optimization for Grid Interactive Voltage Source Inverters , 2010, IEEE Transactions on Industrial Electronics.
[24] Frede Blaabjerg,et al. Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.
[25] Donald Grahame Holmes,et al. Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).
[26] Yan Zhou,et al. Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.
[27] V. Blasko,et al. A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .
[28] Mat Syai'in,et al. Steady‐state solutions of a voltage source converter with dq‐frame controllers by means of the time‐domain method , 2014 .
[29] Marco Liserre,et al. Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.
[30] M. Liserre,et al. Robustness analysis of active damping methods for an inverter connected to the grid with an LCL-filter , 2011, 2011 IEEE Energy Conversion Congress and Exposition.
[31] M. Liserre,et al. A stable three-phase LCL-filter based active rectifier without damping , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..