Comparison of a Planar Thin-Film Thermal AC Voltage Standard up to 1 MHz

This paper presents results of a trilateral comparison with a traveling ac voltage standard comprising a planar thin-film thermal converter. The ac–dc voltage transfer difference of the standard was measured at 1 V and at selected frequencies from 20 Hz to 1 MHz against primary thermal ac voltage standards at the Silesian University of Technology, Istituto Nazionale di Ricerca Metrologica, and Trescal.

[1]  Marian Kampik,et al.  A fast-reversed DC voltage/current source to measure , 2016 .

[2]  M. Klonz CCE comparison of AC-DC voltage transfer standards at the lowest attainable level of uncertainty , 1997 .

[3]  M. Klonz,et al.  APMP international comparison of AC-DC transfer standards at the lowest attainable level of uncertainty , 2004, CPEM 2004.

[4]  E. Kessler,et al.  Low-frequency ac-dc voltage transfer standards with new high sensitivity and low power coefficient thin-film Multijunction Thermal Converters , 2002, CPEM 2002.

[5]  Rado Lapuh,et al.  Low-frequency ac-dc voltage transfer standards with new high sensitivity and low power coefficient thin-film Multijunction Thermal Converters , 2002, Conference Digest Conference on Precision Electromagnetic Measurements.

[6]  M Klonz CCEM-K6.a: key comparison of ac-dc voltage transfer standards at the lowest attainable level of uncertainty , 2002 .

[7]  Rado Lapuh,et al.  Determination of the AC-DC Voltage Transfer Difference of High Voltage Transfer Standards at Low Frequencies , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[8]  M. Klonz,et al.  Determination of the time-constants of thermoelectric effects in thermal converters using a fast-reversed DC , 1996, Proceedings of 20th Biennial Conference on Precision Electromagnetic Measurements.

[9]  Bruno Trinchera,et al.  Trilateral comparison of a planar thin-film thermal AC voltage standard up to 1 MHz , 2016, 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016).

[10]  U. Pogliano,et al.  Determination of the frequency dependence of the AC/DC voltage standard at IEN , 1996, Proceedings of 20th Biennial Conference on Precision Electromagnetic Measurements.

[11]  M. Klonz,et al.  AC-DC voltage transfer difference of the PTB-multijunction thermal converter at 1 MHz , 1990, Conference on Precision Electromagnetic Measurements.

[12]  M. Cox The evaluation of key comparison data , 2002 .

[13]  M. Klonz AC-DC transfer difference of the PTB multijunction thermal converter in the frequency range from 10 Hz to 100 kHz , 1987, IEEE Transactions on Instrumentation and Measurement.

[14]  Umberto Pogliano,et al.  High-Precision Thermal EMF Comparator for Automatic AC-DC Transfer Measurements , 1983, IEEE Transactions on Instrumentation and Measurement.

[15]  Marian Kampik,et al.  Calculable AC Voltage Standards for 10 kHz-1 MHz Frequency Range , 2017, IEEE Transactions on Instrumentation and Measurement.

[16]  Marian Kampik,et al.  Calculable thermal AC voltage standards for 10 kHz–1 MHz frequency range , 2016, 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016).