Self-partitioning SlipChip for slip-induced droplet formation and human papillomavirus viral load quantification with digital LAMP.

Human papillomavirus (HPV) is one of the most common sexually transmitted infections worldwide, and persistent HPV infection can cause warts and even cancer. Nucleic acid analysis of HPV viral DNA can be very informative for the diagnosis and monitoring of HPV. Digital nucleic acid analysis, such as digital PCR and digital isothermal amplification, can provide sensitive detection and precise quantification of target nucleic acids, and its utility has been demonstrated in many biological research and medical diagnostic applications. A variety of methods have been developed for the generation of a large number of individual reaction partitions, a key requirement for digital nucleic acid analysis. However, an easily assembled and operated device for robust droplet formation without preprocessing devices, auxiliary instrumentation or control systems is still highly desired. In this paper, we present a self-partitioning SlipChip (sp-SlipChip) microfluidic device for the slip-induced generation of droplets to perform digital loop-mediated isothermal amplification (LAMP) for the detection and quantification of HPV DNA. In contrast to traditional SlipChip methods, which require the precise alignment of microfeatures, this sp-SlipChip utilized a design of "chain-of-pearls" continuous microfluidic channel that is independent of the overlapping of microfeatures on different plates to establish the fluidic path for reagent loading. Initiated by a simple slipping step, the aqueous solution can robustly self-partition into individual droplets by capillary pressure-driven flow. This advantage makes the sp-SlipChip very appealing for the point-of-care quantitative analysis of viral load. As a proof of concept, we performed digital LAMP on a sp-SlipChip to quantify human papillomaviruses (HPVs) 16 and 18 and tested this method with fifteen anonymous clinical samples.

[1]  P. Laurent-Puig,et al.  Multiplex picodroplet digital PCR to detect KRAS mutations in circulating DNA from the plasma of colorectal cancer patients. , 2013, Clinical chemistry.

[2]  Todd Munson,et al.  Theoretical design and analysis of multivolume digital assays with wide dynamic range validated experimentally with microfluidic digital PCR. , 2011, Analytical chemistry.

[3]  R. Ismagilov,et al.  Control of initiation, rate, and routing of spontaneous capillary-driven flow of liquid droplets through microfluidic channels on SlipChip. , 2012, Langmuir : the ACS journal of surfaces and colloids.

[4]  Ying Zhu,et al.  Printing 2-Dimentional Droplet Array for Single-Cell Reverse Transcription Quantitative PCR Assay with a Microfluidic Robot , 2015, Scientific Reports.

[5]  Fangli Zhang,et al.  Centrifugal micro-channel array droplet generation for highly parallel digital PCR. , 2017, Lab on a chip.

[6]  Tak Y. Leung,et al.  Digital PCR for the molecular detection of fetal chromosomal aneuploidy , 2007, Proceedings of the National Academy of Sciences.

[7]  Meng Xiao,et al.  An integrated microfluidic device utilizing dielectrophoresis and multiplex array PCR for point-of-care detection of pathogens. , 2014, Lab on a chip.

[8]  Chen Zhang,et al.  Visual Detection of High-Risk Human Papillomavirus Genotypes 16, 18, 45, 52, and 58 by Loop-Mediated Isothermal Amplification with Hydroxynaphthol Blue Dye , 2011, Journal of Clinical Microbiology.

[9]  E. Schuuring,et al.  Nationwide prevalence of human papillomavirus infection and viral genotype distribution in 37 cities in China , 2015, BMC Infectious Diseases.

[10]  Fan Shen,et al.  Next generation digital PCR measurement of hepatitis B virus copy number in formalin-fixed paraffin-embedded hepatocellular carcinoma tissue. , 2015, Clinical chemistry.

[11]  M. Seoud,et al.  Cervical adenocarcinoma: moving towards better prevention. , 2011, Vaccine.

[12]  Bing Sun,et al.  Multiplexed quantification of nucleic acids with large dynamic range using multivolume digital RT-PCR on a rotational SlipChip tested with HIV and hepatitis C viral load. , 2011, Journal of the American Chemical Society.

[13]  Enrico Gratton,et al.  Digital quantification of miRNA directly in plasma using integrated comprehensive droplet digital detection. , 2015, Lab on a chip.

[14]  Jane Ru Choi,et al.  Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications. , 2017, Biosensors & bioelectronics.

[15]  Zhenming Hu,et al.  A highly integrated real-time digital PCR device for accurate DNA quantitative analysis. , 2019, Biosensors & bioelectronics.

[16]  M. Plummer,et al.  Global burden of cancers attributable to infections in 2008: a review and synthetic analysis. , 2012, The Lancet. Oncology.

[17]  Susan S. Huang,et al.  Rapid detection of single bacteria in unprocessed blood using Integrated Comprehensive Droplet Digital Detection , 2014, Nature Communications.

[18]  F. X. Bosch,et al.  Epidemiologic classification of human papillomavirus types associated with cervical cancer. , 2003, The New England journal of medicine.

[19]  Seri Jeong,et al.  Comparison of the Abbott RealTime High-Risk Human Papillomavirus (HPV), Roche Cobas HPV, and Hybrid Capture 2 Assays to Direct Sequencing and Genotyping of HPV DNA , 2012, Journal of Clinical Microbiology.

[20]  Gang Li,et al.  Absolute quantification of DNA methylation using microfluidic chip-based digital PCR. , 2017, Biosensors & bioelectronics.

[21]  C. Klapperich,et al.  Cell lysis and DNA extraction of gram-positive and gram-negative bacteria from whole blood in a disposable microfluidic chip. , 2009, Lab on a chip.

[22]  Jesus Rodriguez-Manzano,et al.  Reading Out Single-Molecule Digital RNA and DNA Isothermal Amplification in Nanoliter Volumes with Unmodified Camera Phones , 2016, ACS nano.

[23]  Jiasi Wang,et al.  Self-digitization chip for quantitative detection of human papillomavirus gene using digital LAMP. , 2019, Lab on a chip.

[24]  Manhua Liu,et al.  Assembled Step Emulsification Device for Multiplex Droplet Digital Polymerase Chain Reaction. , 2019, Analytical chemistry.

[25]  Jianlong Zhao,et al.  Absolute quantification and analysis of extracellular vesicle lncRNAs from the peripheral blood of patients with lung cancer based on multi-colour fluorescence chip-based digital PCR. , 2019, Biosensors & bioelectronics.

[26]  Stephen R. Quake,et al.  Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria , 2006, Science.

[27]  Jeff Mellen,et al.  High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy Number , 2011, Analytical chemistry.

[28]  Liang Li,et al.  User-loaded SlipChip for equipment-free multiplexed nanoliter-scale experiments. , 2010, Journal of the American Chemical Society.

[29]  R. Ismagilov,et al.  High-Throughput Single-Cell Cultivation on Microfluidic Streak Plates , 2016, Applied and Environmental Microbiology.

[30]  James Mitchell Crow,et al.  HPV: The global burden , 2012, Nature.

[31]  S. Ratnam,et al.  Novel Microsphere-Based Method for Detection and Typing of 46 Mucosal Human Papillomavirus Types , 2011, Journal of Clinical Microbiology.

[32]  R. Ismagilov,et al.  Multistep SlipChip for the Generation of Serial Dilution Nanoliter Arrays and Hepatitis B Viral Load Quantification by Digital Loop Mediated Isothermal Amplification. , 2019, Analytical chemistry.

[33]  Pingan Zhu,et al.  Passive and active droplet generation with microfluidics: a review. , 2016, Lab on a chip.

[34]  Anupam Singhal,et al.  Megapixel digital PCR , 2011, Nature Methods.

[35]  Bing Sun,et al.  Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol. , 2013, Analytical chemistry.

[36]  R. Ismagilov,et al.  Flow-through Capture and in Situ Amplification Can Enable Rapid Detection of a Few Single Molecules of Nucleic Acids from Several Milliliters of Solution. , 2016, Analytical chemistry.

[37]  Peng Xu,et al.  Bacterial chemotaxis on SlipChip. , 2014, Lab on a chip.

[38]  Rustem F Ismagilov,et al.  Digital isothermal quantification of nucleic acids via simultaneous chemical initiation of recombinase polymerase amplification reactions on SlipChip. , 2011, Analytical chemistry.

[39]  Tanyu Wang,et al.  Programmable active droplet generation enabled by integrated pneumatic micropumps. , 2013, Lab on a chip.

[40]  Rustem F Ismagilov,et al.  Digital PCR on a SlipChip. , 2010, Lab on a chip.