Impact of arbitrary and mean transfer of dental casts to the articulator on centric occlusal errors

When fabricating dental restorations, casts are usually transferred to the articulator based on arbitrary hinge axes or mean values instead of true hinge axis points. Using arbitrary hinge axis points or mean values can lead to occlusal errors if the vertical relation is changed in the articulator (e.g., when a centric record is used). This study predicted the probability of occlusal errors occurring in a group of subjects when casts are mounted based on arbitrary hinge axis points or mean values. In 57 healthy volunteers, true hinge axis points, arbitrary hinge axis points, right infraorbital point, maxillary incisal point, and the palatal cusps of the second molars were determined. Mean hinge axis points were established based on Balkwill angles between 17° and 25°. Occlusal errors evoked by cast mounting in relation to arbitrary or mean axes compared to true hinge axes were calculated. Errors were determined for vertical relation settings of 2 and 4 mm. With 2 mm vertical relation, occlusal errors ≥340 µm occurred with a 10% probability with arbitrary hinge axis mounting. At the same probability level, the error increased moderately to ≥440 µm with mean value mounting and a Balkwill angle of 17°. With a Balkwill angle of 25° occlusal errors ≥1,120 µm occurred with 10% probability. Occlusal errors increased considerably with a vertical relation setting of 4 mm. If vertical relation shall be altered, a transfer of the casts according to arbitrary hinge axes is recommended. If casts are transferred according to mean values, errors are bigger depending on the articulator used.

[1]  Lawrence A. Weinberg,et al.  An evaluation of basic articulators and their concepts: Part II. Arbitrary, positional, semi adjustable articulators , 1963 .

[2]  P. Pröschel,et al.  Predicted incidence of excursive occlusal errors in common modes of articulator adjustment. , 2000, The International journal of prosthodontics.

[3]  G. Bergstrom On the reproduction of dental articulation by means of articulators. , 1950, Acta odontologica Scandinavica. Supplementum.

[4]  Heinz O. Beck,et al.  A clinical evaluation of the arcon concept of articulation , 1959 .

[5]  G. B. Pelleu,et al.  Arbitrary mandibular hinge axis locations. , 1984, The Journal of prosthetic dentistry.

[6]  Thure Brandrup-Wognsen,et al.  The face-bow, its significance and application , 1953 .

[7]  D. N. Brotman Hinge axes Part II. Geometric significance of the transverse axis , 1960 .

[8]  P Adrien,et al.  Methods for minimizing the errors in mandibular model mounting on an articulator. , 1997, Journal of oral rehabilitation.

[9]  W R Teteruck,et al.  The accuracy of an ear face-bow. , 1966, The Journal of prosthetic dentistry.

[10]  P M Walker,et al.  Discrepancies between arbitrary and true hinge axes. , 1980, The Journal of prosthetic dentistry.

[11]  E Piehslinger,et al.  Computer simulation of occlusal discrepancies resulting from different mounting techniques. , 1995, The Journal of prosthetic dentistry.

[12]  Arne G. Lauritzen,et al.  Hinge axis location on an experimental basis , 1961 .

[13]  Arne G. Lauritzen,et al.  Variations in location of arbitrary and true hinge axis points , 1961 .

[14]  J. Silness,et al.  The size of the Balkwill angle and the height of the Bonwill triangle. , 1982, Journal of oral rehabilitation.

[15]  A. Erdman,et al.  Three-dimensional analysis of cusp travel during a nonworking mandibular movement. , 1985, The Journal of prosthetic dentistry.

[16]  G R Zuckerman,et al.  The geometry of the arbitrary hinge axis as it relates to the occlusion. , 1982, The Journal of prosthetic dentistry.

[17]  L. Tippett Statistical Tables: For Biological, Agricultural and Medical Research , 1954 .

[18]  S. Gordon,et al.  Location of the terminal hinge axis and its effect on the second molar cusp position. , 1984, The Journal of prosthetic dentistry.

[19]  Lawrence A. Weinberg,et al.  An evaluation of basic articulators and their concepts: Part III. Fully adjustable articulators , 1963 .

[20]  F. W. Craddock,et al.  Evaluation of the face-bow , 1952 .

[21]  P. Pröschel,et al.  Differences between traces of adjacent condylar points and their impact on clinical evaluation of condyle motion. , 1998, The International journal of prosthodontics.

[22]  Robert G. Schallhorn,et al.  A study of the arbitrary center and the kinematic center of rotation for face-bow mountings , 1957 .

[23]  B. Koeck Funktionsstörungen des Kauorgans , 1995 .

[24]  A. Björk Some biological aspects of prognathism and occlusion of the teeth. , 1950 .

[25]  A G Erdman,et al.  The hinge axis transfer procedure: a three-dimensional error analysis. , 1984, The Journal of prosthetic dentistry.

[26]  S Hobo,et al.  Articulator selection for restorative dentistry. , 1976, The Journal of prosthetic dentistry.