Development of a stationary chest tomosynthesis system using carbon nanotube x-ray source array
暂无分享,去创建一个
[1] Nico Lanconelli,et al. A new clinical unit for digital radiography based on a thick amorphous selenium plate: physical and psychophysical characterization. , 2011, Medical physics.
[2] A. Flinck,et al. Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. , 2008, Radiology.
[3] R. Gomer,et al. Field Emission and Field Ionization , 1961 .
[4] Guohua Cao,et al. Prospective respiratory gated carbon nanotube micro computed tomography. , 2011, Academic radiology.
[5] H. Machida. Optimizing Parameters for Flat-Panel Detector , 2010 .
[6] Tuyen Phan,et al. Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis. , 2009, Medical physics.
[7] D. G. Grant. Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.
[8] Lubomir M. Hadjiiski,et al. A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. , 2006, Medical physics.
[9] Emilio Quaia,et al. Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography , 2012, European Radiology.
[10] Yuan Cheng,et al. Rectangular Fixed-Gantry CT Prototype: Combining CNT X-Ray Sources and Accelerated Compressed Sensing-Based Reconstruction , 2014, IEEE Access.
[11] Guohua Cao,et al. Carbon Nanotube based X-ray Sources: Applications in Pre-Clinical and Medical Imaging. , 2011, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.
[12] Guohua Cao,et al. Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray. , 2010, Medical physics.
[13] Otto Zhou,et al. Evaluation of imaging geometry for stationary chest tomosynthesis , 2014, Medical Imaging.
[14] Yuan Cheng,et al. Rectangular computed tomography using a stationary array of CNT emitters: initial experimental results , 2013, Medical Imaging.
[15] Renuka Uppaluri,et al. Effect of acquisition parameters on image quality in digital tomosynthesis , 2007, SPIE Medical Imaging.
[16] Tomokazu Numano,et al. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT. , 2012, European journal of radiology.
[17] I. Björkman-Burtscher,et al. Radiography, tomosynthesis, CT and MRI in the evaluation of pulmonary cystic fibrosis: an untangling review of the multitude of scoring systems , 2013, Insights into Imaging.
[18] M J Paulus,et al. High resolution X-ray computed tomography: an emerging tool for small animal cancer research. , 2000, Neoplasia.
[19] Kunio Doi,et al. A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.
[20] Guohua Cao,et al. Design and characterization of a carbon-nanotube-based micro-focus x-ray tube for small animal imaging , 2010, Medical Imaging.
[21] W. D. de Heer,et al. A Carbon Nanotube Field-Emission Electron Source , 1995, Science.
[22] Andrea Viti,et al. Lung Cancer Detection with Digital Chest Tomosynthesis: Baseline Results from the Observational Study SOS , 2013, Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer.
[23] L Barozzi,et al. Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography. , 2006, The British journal of radiology.
[24] Kyung Soo Lee,et al. Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection , 2013, Acta radiologica.
[25] Otto Zhou,et al. Demonstration of a scatter correction technique in digital breast tomosynthesis , 2013, Medical Imaging.
[26] W. Hop,et al. Progression of lung disease on computed tomography and pulmonary function tests in children and adults with cystic fibrosis , 2005, Thorax.
[27] Otto Zhou,et al. Stationary scanning x-ray source based on carbon nanotube field emitters , 2005 .
[28] Kenji Ogawa,et al. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference , 2013, European Radiology.
[29] R Peng,et al. A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source , 2009, Physics in medicine and biology.
[30] David W. Archer,et al. Microbeam radiation therapy , 1999, Optics & Photonics.
[31] S. Iijima. Helical microtubules of graphitic carbon , 1991, Nature.
[32] Laureline Berteloot,et al. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis , 2013, Pediatric Radiology.
[33] Ehsan Samei,et al. A framework for optimising the radiographic technique in digital X-ray imaging. , 2005, Radiation protection dosimetry.
[34] John M. Sabol,et al. A Monte Carlo estimation of effective dose in chest tomosynthesis. , 2009, Medical physics.
[35] Thomas Mertelmeier,et al. Experimental validation of a three-dimensional linear system model for breast tomosynthesis. , 2008, Medical physics.
[36] O. Zhou,et al. Carbon nanotube electron field emitters for x-ray imaging of human breast cancer , 2014, Nanotechnology.
[37] Otto Zhou,et al. Anode thermal analysis of high power microfocus CNT x-ray tubes for in vivo small animal imaging , 2012, Medical Imaging.
[38] Xinhua Li,et al. A generic geometric calibration method for tomographic imaging systems with flat-panel detectors--a detailed implementation guide. , 2010, Medical physics.
[39] K. Hori,et al. Development of ultra-fast X-ray computed tomography scanner system , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.
[40] Yiheng Zhang,et al. High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array. , 2012, Medical physics.
[41] I. Björkman-Burtscher,et al. Effective dose from chest tomosynthesis in children. , 2014, Radiation protection dosimetry.
[42] G T Barnes,et al. Contrast and scatter in x-ray imaging. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.
[43] Otto Zhou,et al. Feasibility study of the diagnosis and monitoring of cystic fibrosis in pediatric patients using stationary digital chest tomosynthesis , 2015, Medical Imaging.
[44] J. Boone,et al. Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner. , 2006, Medical physics.
[45] Otto Zhou,et al. Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study , 2015, Physics in medicine and biology.
[46] Otto Zhou,et al. Generation of continuous and pulsed diagnostic imaging x-ray radiation using a carbon-nanotube-based field-emission cathode , 2002 .
[47] Jonathan S. Maltz,et al. Fixed gantry tomosynthesis system for radiation therapy image guidance based on a multiple source x-ray tube with carbon nanotube cathodes. , 2009 .
[48] Tsutomu Gomi,et al. Clinical Potential of Digital Linear Tomosynthesis Imaging of Total Joint Arthroplasty , 2008, Journal of Digital Imaging.
[49] R Clackdoyle,et al. Centers and centroids of the cone-beam projection of a ball , 2011, Physics in medicine and biology.
[50] Santiago Martinez-Jimenez,et al. Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. , 2008, Medical physics.
[51] Benjamin M. W. Tsui,et al. Principles of Medical Imaging , 1992 .
[52] H. Sugie,et al. Carbon nanotubes as electron source in an x-ray tube , 2001 .
[53] Otto Zhou,et al. Low dose scatter correction for digital chest tomosynthesis , 2015, Medical Imaging.
[54] Willi A. Kalender,et al. Computed tomography : fundamentals, system technology, image quality, applications , 2000 .
[55] Tao Wu,et al. A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.
[56] W. Schubert,et al. Tungsten: Properties, Chemistry, Technology of the Element, Alloys, and Chemical Compounds , 1999 .
[57] 齋藤 弥八,et al. Carbon nanotube and related field emitters : fundamentals and applications , 2010 .
[58] J. Strzelczyk. The Essential Physics of Medical Imaging , 2003 .
[59] Hiroaki Sugiura,et al. Fast Scanning Tomosynthesis for the Detection of Pulmonary Nodules: Diagnostic Performance Compared With Chest Radiography, Using Multidetector-Row Computed Tomography as the Reference , 2011, Investigative radiology.
[60] C P Lawinski,et al. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis. , 2012, Clinical radiology.
[61] Otto Zhou,et al. Adapted fan-beam volume reconstruction for stationary digital breast tomosynthesis , 2015, Medical Imaging.
[62] Andrew D. A. Maidment,et al. Dynamic reconstruction and rendering of 3D tomosynthesis images , 2011, Medical Imaging.
[63] Jenny Vikgren,et al. Chest Tomosynthesis: Technical and Clinical Perspectives , 2014, Seminars in Respiratory and Critical Care Medicine.
[64] Magnus Båth,et al. Effective dose to patients from chest examinations with tomosynthesis. , 2010, Radiation protection dosimetry.
[65] D E Grider,et al. Electron beam melting in microfocus X-ray tubes , 1986 .
[66] Magnus Båth,et al. Monte Carlo simulations of the dosimetry of chest tomosynthesis. , 2010, Radiation protection dosimetry.
[67] Michael M Maher,et al. Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients. , 2010, Radiology.
[68] M. Baxendale. The physics and applications of carbon nanotubes , 2003 .
[69] R. Fowler,et al. Electron Emission in Intense Electric Fields , 1928 .
[70] Mats Geijer,et al. Description and validation of a scoring system for tomosynthesis in pulmonary cystic fibrosis , 2012, European Radiology.
[71] P Laganis,et al. A first generation compact microbeam radiation therapy system based on carbon nanotube X-ray technology. , 2013, Applied physics letters.
[72] Michael J. Flynn,et al. Spatial resolution of x-ray tomosynthesis in relation to computed tomography for coronal/sagittal images of the knee , 2007, SPIE Medical Imaging.
[73] L. Rosenhead. Conduction of Heat in Solids , 1947, Nature.
[74] John M Boone,et al. X-ray imaging physics for nuclear medicine technologists. Part 2: X-ray interactions and image formation. , 2005, Journal of nuclear medicine technology.
[75] Michael J. Flynn,et al. Microfocus X-ray sources for 3D microtomography , 1994 .
[76] Michael Sandborg,et al. Investigation of the effect of varying scatter-to-primary ratios on nodule contrast in chest tomosynthesis , 2011, Medical Imaging.
[77] Anders Tingberg,et al. X-ray tomosynthesis: a review of its use for breast and chest imaging. , 2010, Radiation protection dosimetry.
[78] Kyung Soo Lee,et al. Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography. , 2010, Radiology.
[79] Otto Zhou,et al. Stationary chest tomosynthesis using a CNT x-ray source array , 2013, Medical Imaging.
[80] Otto Zhou,et al. Prospective gated chest tomosynthesis using CNT X-ray source array , 2015, Medical Imaging.
[81] Klaus Bacher,et al. Digital tomosynthesis in the detection of urolithiasis: Diagnostic performance and dosimetry compared with digital radiography with MDCT as the reference standard. , 2010, AJR. American journal of roentgenology.
[82] Mats Geijer,et al. Tomosynthesis in pulmonary cystic fibrosis with comparison to radiography and computed tomography: a pictorial review , 2011, Insights into Imaging.
[83] S. Okayama,et al. Penetration and energy-loss theory of electrons in solid targets , 1972 .
[84] Steve B. Jiang,et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.
[85] Erik L Ritman,et al. Current status of developments and applications of micro-CT. , 2011, Annual review of biomedical engineering.
[86] Yulia M. Levakhina. Three-dimensional digital tomosynthesis: iterative reconstruction, artifact reduction and alternative acquisition geometry , 2014 .
[87] P. Sly,et al. Progression of early structural lung disease in young children with cystic fibrosis assessed using CT , 2011, Thorax.
[88] O. Srivastava,et al. Synthesis of carbon nanotubes. , 2005, Journal of nanoscience and nanotechnology.
[89] Otto Zhou,et al. Dependency of image quality on system configuration parameters in a stationary digital breast tomosynthesis system. , 2013, Medical physics.
[90] C. Beaulieu,et al. Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study. , 2003, Radiology.
[91] James T. Dobbins,et al. Chest tomosynthesis: technical principles and clinical update. , 2009, European journal of radiology.
[92] Young Hee Lee,et al. Fully sealed, high-brightness carbon-nanotube field-emission display , 1999 .