Optimal location of shedding load at the adaptive UFLS

Under Frequency Load Shedding, UFLS, is the last step and the most extreme in protecting electric power systems from black outs and severe damages. Load shedding relays are installed at constant locations in the system. These locations are usually substations feeding less important loads. This lack of intelligence in selection of the loads to be shed may result in some problems for the power system after the disturbance. An adaptive selection of load to be shed is suggested using the benefits of wide area protection. The simulation results demonstrate a considerable advantage in minimizing load to be shed.

[1]  Majid Sanaye-Pasand,et al.  New centralised adaptive load-shedding algorithms to mitigate power system blackouts , 2009 .

[2]  Guo Zhizhong,et al.  PMU placement and data processing in WAMS that complements SCADA , 2005, IEEE Power Engineering Society General Meeting, 2005.

[3]  Deqiang Gan,et al.  Frequency induced risk assessment for a power system accounting uncertainties in operation of protective equipments , 2010 .

[4]  F. Gubina,et al.  Revision of the underfrequency load-shedding scheme of the Slovenian power system , 2005, IEEE Power Engineering Society General Meeting, 2005.

[5]  Ieee Standards Board IEEE recommended practice for excitation system models for power system stability studies , 1992 .

[6]  V. Madani,et al.  Shedding light on blackouts , 2004, IEEE Power and Energy Magazine.

[7]  S. M Chandekar,et al.  Revised load shedding schedule for power system incorporating the effect of transmission line performance , 2002 .

[8]  V. Terzija,et al.  Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006, IEEE Transactions on Power Systems.

[9]  Jin Zhong,et al.  UFLS Design by Using f and Integrating df/dt , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[10]  M. Begovic,et al.  On Wide Area Protection , 2007, 2007 IEEE Power Engineering Society General Meeting.

[11]  Vladimir Terzija Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006 .

[12]  M.A. El-Hadidy,et al.  Starting Synchrophasor measurements in Egypt: A pilot project using fault recorders , 2008, 2008 12th International Middle-East Power System Conference.

[13]  A.G. Phadke,et al.  HISTORY AND APPLICATIONS OF PHASOR MEASUREMENTS , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[14]  James S. Thorp,et al.  IEEE Standard for Synchrophasors for Power Systems , 1998 .

[15]  H. Happ Power system control and stability , 1979, Proceedings of the IEEE.

[16]  Olle I. Elgerd,et al.  Electric Energy Systems Theory: An Introduction , 1972 .

[17]  Damir Novosel,et al.  Wide-Area Protection and Emergency Control , 2004, Proceedings of the IEEE.

[18]  M. M. Sallam,et al.  Adaptive Under Frequency Load Shedding using PMU , 2009, 2009 7th IEEE International Conference on Industrial Informatics.

[19]  E. Price,et al.  Practical considerations for implementing wide area monitoring, protection and control , 2006, 59th Annual Conference for Protective Relay Engineers, 2006..