Development and characterization of thermopneumatic peristaltic micropumps

In this paper, the development and characterization of thermopneumatic peristaltic micropumps are presented. Micropumps with three different designs are fabricated using soft lithography techniques. The equivalent circuit models of a thermopneumatic actuation cell are formulated. The analytical solutions for predicting the device transient behavior are also derived. The dynamical responses of the diaphragms are measured using an interferometer, and are in good agreement with the modeled results. Tiny drive circuits, which require only 5 V, are implemented for driving the pumps. The dimension of an integrated 3-chamber micropump system, which consists of a pump and a drive circuit, is 16 mm × 18 mm × 5.5 mm. The optimal operating conditions, such as actuation sequences, operating frequencies and duty ratios, are obtained. The maximum flow rate occurs at a driving frequency of 1.5 Hz with a duty ratio of 40% using a three-phase actuation sequence. A simplified pseudo thermo-fluid-structure-interaction (pT-FSI) model is also proposed to estimate the pumping characteristic. The model gives reasonable results under low operation frequency. Under zero backpressure, the maximum flow rates for the 3, 5 and 7-chamber devices are very close, whereas the devices with larger numbers of pumping chambers exhibit better pumping performance under higher backpressure.

[1]  Nam-Trung Nguyen,et al.  A fully polymeric micropump with piezoelectric actuator , 2004 .

[2]  G. Stemme,et al.  Micromachined flat-walled valveless diffuser pumps , 1997 .

[3]  Guo-Hua Feng,et al.  Piezoelectrically actuated dome-shaped diaphragm micropump , 2005 .

[4]  Peter Woias,et al.  A generic analytical model for micro-diaphragm pumps with active valves , 2005 .

[5]  M. Gijs,et al.  A high-performance compact electromagnetic actuator for a PMMA ball-valve micropump , 2008 .

[6]  Alan G. R. Evans,et al.  Investigation for the operation of an integrated peristaltic micropump , 2004 .

[7]  Hans Zappe,et al.  Thermo-pneumatically actuated, membrane-based micro-mirror devices , 2006 .

[8]  Yael Nemirovsky,et al.  A membrane micropump electrostatically actuated across the working fluid , 2005 .

[9]  Mi-Ching Tsai,et al.  A stand-alone peristaltic micropump based on piezoelectric actuation , 2007, Biomedical microdevices.

[10]  E. S. Kim,et al.  Micropump based on PZT unimorph and one-way parylene valves , 2004 .

[11]  Christopher D. Batich,et al.  Fabrication and testing of a magnetically actuated micropump , 2002 .

[12]  Linda G. Griffith,et al.  Design, modeling and fabrication of a constant flow pneumatic micropump , 2007 .

[13]  Zheng Cui,et al.  A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistance , 2008 .

[14]  Satoshi Konishi,et al.  Fabrication and drive test of pneumatic PDMS micro pump , 2007 .

[15]  P. Bergveld,et al.  A plastic micropump constructed with conventional techniques and materials , 1999 .

[16]  Juan G. Santiago,et al.  A review of micropumps , 2004 .

[17]  M. Richter,et al.  A bidirectional silicon micropump , 1995 .

[18]  O. Jeong,et al.  A phase-change type micropump with aluminum flap valves , 2003 .

[19]  Gwo-Bin Lee,et al.  Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels , 2006 .

[20]  Yong-Sang Kim,et al.  A disposable thermopneumatic-actuated micropump stacked with PDMS layers and ITO-coated glass , 2005 .

[21]  Ok Chan Jeong,et al.  Fabrication of a peristaltic PDMS micropump , 2005 .