Patient movement compensation for 3D echocardiography fusion

Limited field of view (FOV) is a major problem for 3D real-time echocardiography (3DRTE), which results in an incomplete representation of cardiac anatomy. Various image registration techniques have been proposed to improve the field of view in 3DRTE by fusing multiple image volumes. However, these techniques require significant overlap between the individual volumes and rely on high image resolution and high signal-to-noise ratio. Changes in the heart position due to patient movement during image acquisition can also reduce the quality of image fusion. In this paper, we propose a multi-camera based optical tracking system which 1) eliminates the need for image overlap and 2) compensates for patient movement during acquisition. We compensate for patient movement by continuously tracking the patient position using skin markers and incorporating this information into the fusion process. We fuse volumes acquired during R-R wave peaks based on Electrocardiogram (ECG) data to account for retrospective image acquisition. The fusion technique was validated using a heart phantom (Shelley Medical Imaging Technologies) and on one healthy volunteer. The fused ultrasound volumes could be generated in within 2 seconds and were found to have complete myocardial boundaries alignment upon visual assessment. No stitching artefacts or movement related artefacts were observed in the fused image.

[1]  K. Rhode,et al.  Real-time compounding of three-dimensional transesophageal echocardiographic volumes: The phantom study , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  Jonathan Chan,et al.  Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters. , 2006, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[3]  Kumaradevan Punithakumar,et al.  Cardiac ultrasound multiview fusion using a multicamera tracking system , 2014, IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).

[4]  Harald Becher,et al.  3D fusion echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography , 2013 .

[5]  Berthold K. P. Horn,et al.  Closed-form solution of absolute orientation using unit quaternions , 1987 .

[6]  Kashif Rajpoot,et al.  Investigating 3D echocardiography image fusion for improving image quality , 2013, 2013 3rd IEEE International Conference on Computer, Control and Communication (IC4).

[7]  Victor Mor-Avi,et al.  Three-dimensional echocardiography: the benefits of the additional dimension. , 2006, Journal of the American College of Cardiology.

[8]  T. Marwick,et al.  Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. , 2004, Journal of the American College of Cardiology.

[9]  L. Sugeng,et al.  Real-time 3-dimensional echocardiography: an integral component of the routine echocardiographic examination in adult patients? , 2009, Circulation.

[10]  Kashif Rajpoot,et al.  The evaluation of single-view and multi-view fusion 3D echocardiography using image-driven segmentation and tracking , 2011, Medical Image Anal..

[11]  Kawal S. Rhode,et al.  Ultrasound calibration using intensity-based image registration: for application in cardiac catheterization procedures , 2008, SPIE Medical Imaging.

[12]  Tobias Schaeffter,et al.  Multi-view 3D echocardiography compounding based on feature consistency , 2011, Physics in medicine and biology.

[13]  J. Noble,et al.  Multiview fusion 3-D echocardiography: improving the information and quality of real-time 3-D echocardiography. , 2011, Ultrasound in Medicine and Biology.

[14]  Alejandro F. Frangi,et al.  Multiview diffeomorphic registration: Application to motion and strain estimation from 3D echocardiography , 2013, Medical Image Anal..