Stability of IgG1 monoclonal antibodies in intravenous infusion bags under clinical in-use conditions.

Compounding pharmacists are expected to prepare safe and efficacious doses of medication under time and economical constraints while protecting pharmacy staff and caregivers from inadvertent exposure to the drug. The pharmacist has the additional responsibility to ensure that the product is stable in the final-administrated form as the time between drug preparation and administration is considerable. Pharmacists are responsible for setting a "beyond-use" date based on United States Pharmacopeia 797, wherein the beyond-use date for the compounded sterile preparation (CSP) is defined as the time by which the compounded preparation must be used to avoid risks for product degradation, contamination, and so on. Physical and chemical stability of the CSP can be difficult to maintain over extended storage, especially since the formulation components are diluted within the intravenous (i.v.) bag contents. Recent published reports have suggested the use of extended time, beyond that recommended by the manufacturer, for the storage and administration of CSP. These recommendations were based on inadequate analytical testing of the CSP. Herein, we demonstrate that setting of the beyond-use date should be carefully assessed using the appropriate analytical methods and testing. Results from our studies clearly indicate that many of the tested IgG(1) monoclonal antibodies should not be diluted and stored in i.v. bags over extended period of time, and particularly should not be transported after dilution in the infusion bags without consulting the manufacturer. Results from this study also indicate that i.v. bag agitation studies should be performed during pharmaceutical development of protein therapeutics under clinical in-use conditions, especially when storage and transportation of i.v. bags are possible in global clinical trials and post-licensure usage.

[1]  M Kupfer,et al.  Stability of alemtuzumab in infusion-bags. , 2009, Die Pharmazie.

[2]  B. Kerwin Polysorbates 20 and 80 used in the formulation of protein biotherapeutics: structure and degradation pathways. , 2008, Journal of pharmaceutical sciences.

[3]  R. Hodges,et al.  Salt effects on protein stability: two-stranded alpha-helical coiled-coils containing inter- or intrahelical ion pairs. , 1997, Journal of molecular biology.

[4]  Hanns-Christian Mahler,et al.  Protein aggregation: pathways, induction factors and analysis. , 2009, Journal of pharmaceutical sciences.

[5]  Saranjit Singh,et al.  Development of validated stability-indicating assay methods--critical review. , 2002, Journal of pharmaceutical and biomedical analysis.

[6]  Wei Wang,et al.  Protein aggregation--pathways and influencing factors. , 2010, International journal of pharmaceutics.

[7]  V. Katta,et al.  Leachables from Saline-Containing IV Bags Can Alter Therapeutic Protein Properties , 2010, Pharmaceutical Research.

[8]  M. Deonarain Recombinant antibodies for cancer therapy , 2008, Expert opinion on biological therapy.

[9]  Wei Wang,et al.  Antibody structure, instability, and formulation. , 2007, Journal of pharmaceutical sciences.

[10]  J. Kolesar,et al.  Stability of cetuximab and panitumumab in glass vials and polyvinyl chloride bags. , 2010, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[11]  Steven Kozlowski,et al.  Overlooking subvisible particles in therapeutic protein products: gaps that may compromise product quality. , 2009, Journal of pharmaceutical sciences.

[12]  L. Narhi,et al.  Physical and biophysical effects of polysorbate 20 and 80 on darbepoetin alfa. , 2009, Journal of pharmaceutical sciences.

[13]  Hanns-Christian Mahler,et al.  Glycation during storage and administration of monoclonal antibody formulations. , 2008, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[14]  Hanns-Christian Mahler,et al.  Shaken, not stirred: mechanical stress testing of an IgG1 antibody. , 2008, Journal of pharmaceutical sciences.

[15]  S. Shire,et al.  Characterization of Particles in Protein Solutions: Reaching the Limits of Current Technologies , 2010, The AAPS Journal.

[16]  G. Wells,et al.  Anti-erythropoietin antibody-mediated pure red cell aplasia after treatment with recombinant erythropoietin products: recommendations for minimization of risk. , 2004, Journal of the American Society of Nephrology : JASN.