Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain

In a previous study (J.B. West et al., J. Comput. Assist. Tomogr., vol. 21, p. 554-66, 1997) the authors demonstrated that automatic retrospective registration algorithms can frequently register magnetic resonance (MR) and computed tomography (CT) images of the brain with an accuracy of better than 2 mm, but in that same study the authors found that such algorithms sometimes fail, leading to errors of 6 mm or more. Before these algorithms can be used routinely in the clinic, methods must be provided for distinguishing between registration solutions that are clinically satisfactory and those that are not. One approach is to rely on a human observer to inspect the registration results and reject images that have been registered with insufficient accuracy. In this paper, the authors present a methodology for evaluating the efficacy of the visual assessment of registration accuracy. Since the clinical requirements for level of registration accuracy are likely to be application dependent, the authors have evaluated the accuracy of the observer's estimate relative to 6 thresholds: 1-6 mm. The performance of the observers was evaluated relative to the registration solution obtained using external fiducial markers that are screwed into the patient's skull and that are visible in both MR and CT images. This fiducial marker system provides the gold standard for the authors' study. Its accuracy is shown to be approximately 0.5 mm. Two experienced, blinded observers viewed 5 pairs of clinical MR and CT brain images, each of which had each been misregistered with respect to the gold standard solution. Fourteen misregistrations were assessed for each image pair with misregistration errors distributed between 0 and 10 mm with approximate uniformity. For each misregistered image pair each observer estimated the registration error (in millimeters) at each of 5 locations distributed around the head using each of 3 assessment methods. These estimated errors were compared with the errors as measured by the gold standard to determine agreement relative to each of the 6 thresholds, where agreement means that the 2 errors lie on the same side of the threshold. The effect of error in the gold standard itself is taken into account in the analysis of the assessment methods. The results were analyzed by means of the Kappa statistic, the agreement rate, and the area of receiver-operating-characteristic (ROC) curves. No assessment performed well at 1 mm, but all methods performed well at 2 mm and higher. For these 5 thresholds, 2 methods agreed with the standard at least 80% of the time and exhibited mean ROC areas greater than 0.84. One of these same methods exhibited Kappa statistics that indicated good agreement relative to chance (Kappa>0.6) between the pooled observers and the standard for these same 5 thresholds. Further analysis demonstrates that the results depend strongly on the choice of the distribution of misregistration errors presented to the observers.

[1]  M. Fitzpatrick A Review of Medical Image Registration , 1993 .

[2]  S. Zeger,et al.  Longitudinal data analysis using generalized linear models , 1986 .

[3]  D L Hill,et al.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. , 1997, Medical physics.

[4]  C. Pelizzari,et al.  Image Analysis of PET Data with the aid of CT and MR Images , 1988 .

[5]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[6]  Q. Mcnemar Note on the sampling error of the difference between correlated proportions or percentages , 1947, Psychometrika.

[7]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[8]  Colin Studholme,et al.  Automated 3-D registration of MR and CT images of the head , 1996, Medical Image Anal..

[9]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[10]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[11]  J. Hanley Receiver operating characteristic (ROC) methodology: the state of the art. , 1989, Critical reviews in diagnostic imaging.

[12]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[13]  Jay B. West,et al.  Derivation of expected registration error for point-based rigid-body registration , 1998, Medical Imaging.

[14]  Benoit M. Dawant,et al.  Comparison and evaluation of retrospective intermodality image registration techniques , 1996, Medical Imaging.

[15]  J. Mazziotta,et al.  Rapid Automated Algorithm for Aligning and Reslicing PET Images , 1992, Journal of computer assisted tomography.

[16]  D. Hill,et al.  Accurate frameless registration of MR and CT images of the head: applications in planning surgery and radiation therapy. , 1994, Radiology.

[17]  V Sturm,et al.  Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. , 1987, Journal of computer assisted tomography.

[18]  Benoit M. Dawant,et al.  Retrospective intermodality registration techniques: surface-based versus volume-based , 1997, CVRMed.

[19]  J. Fitzpatrick,et al.  Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm. , 1998, Journal of computer assisted tomography.

[20]  B. Dawant,et al.  Effect of geometrical distortion correction in MR on image registration accuracy. , 1996, Journal of computer assisted tomography.

[21]  C. Pelizzari,et al.  Accurate Three‐Dimensional Registration of CT, PET, and/or MR Images of the Brain , 1989, Journal of computer assisted tomography.

[22]  G. Marchal,et al.  Multi-modal volume registration by maximization of mutual information , 1997 .

[23]  Guy Marchal,et al.  Automated multi-moda lity image registration based on information theory , 1995 .

[24]  Paul F. Hemler,et al.  Grey value correlation techniques used for automatic matching of CT and MR brain and spine images , 1994, Other Conferences.

[25]  Gerald Q. Maguire,et al.  Correlation Methods for Tomographic Images Using Two and Three Dimensional Techniques , 1986 .

[26]  Colin Studholme,et al.  Automated Multimodality Registration Using the Full Affine Transformation: Application to MR and CT Guided Skull Base Surgery , 1996, VBC.

[27]  Guy Marchal,et al.  Automated multi-modality image registration based on information theory , 1995 .

[28]  R. Sibson Studies in the Robustness of Multidimensional Scaling: Perturbational Analysis of Classical Scaling , 1979 .

[29]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[30]  Gerald Q. Maguire,et al.  Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.

[31]  J. Mugler,et al.  Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE) , 1990, Magnetic resonance in medicine.

[32]  Benoit M. Dawant,et al.  Registration of 3-D images using weighted geometrical features , 1996, IEEE Trans. Medical Imaging.

[33]  Richard A. Robb,et al.  New approach to 3-D registration of multimodality medical images by surface matching , 1992, Other Conferences.

[34]  H. Kraemer,et al.  2 x 2 kappa coefficients: measures of agreement or association. , 1989, Biometrics.

[35]  Richard A. Robb,et al.  Evaluation of 3D multimodality image registration using receiver operating characteristic (ROC) analysis , 1995, Medical Imaging.

[36]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[37]  P. Diggle,et al.  Analysis of Longitudinal Data , 2003 .

[38]  Alan C. Evans,et al.  Anatomical-Functional Correlative Analysis Of The Human Brain Using Three Dimensional Imaging Systems , 1989, Medical Imaging.

[39]  M. Weinstein,et al.  Clinical Decision Analysis , 1980 .

[40]  Ma Bin-rong,et al.  A review of medical image registration , 1999 .