New trends in the electrochemical detection of endocrine disruptors in complex media

Endocrine disruptors (EDCs) are substances existing in the environment which affect animal and human endocrine functions and cause diseases. A small quantity of EDCs can have a serious impact on the body. Currently, enzyme-linked immunosorbent assay (ELISA), high-performance liquid chromatography (HPLC), and other traditional methods are used to detect EDCs. Although their sensitivity and reliability are good, these methods are complex, expensive, and not feasible to use in the field. Electrochemical techniques present good potential for the detection of EDCs owing to their low cost, simple, and wearable instrumentation. This paper presents the new trends in this field over the last 3 years. Some simple materials can allow some EDCs to be directly detected. New designs of biosensors, such as aptasensors, allow a femtomolar limit of detection to be reached. Many types of nanomaterial-based sensors were tested; carbonaceous nanomaterials, such as multiwalled carbon nanotubes (MWCNTs) and reduced graphene oxide (rGO), associated or not with other types of nanoparticles were included in numerous designs. Molecularly imprinted polymer (MIP)-based sensors constitute an emerging field. All the presented electrochemical sensors were successfully tested for the detection of EDCs in different types of real samples.

[1]  Young-Kyu Han,et al.  A spick-and-span approach to the immobilization of horseradish peroxidase on Au nanospheres incorporated with a methionine/graphene biomatrix for the determination of endocrine disruptor bisphenol A , 2017 .

[2]  E. Girotto,et al.  AuNp@MOF composite as electrochemical material for determination of bisphenol A and its oxidation behavior study , 2016 .

[3]  A. Jabbari,et al.  A glassy carbon electrode modified with amino-functionalized graphene oxide and molecularly imprinted polymer for electrochemical sensing of bisphenol A , 2016, Microchimica Acta.

[4]  Haiqun Chen,et al.  A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A , 2018, Microchimica Acta.

[5]  Thiago C. Canevari,et al.  Development of an electrochemical sensor of endocrine disruptor bisphenol A by reduced graphene oxide for incorporation of spherical carbon nanoparticles , 2019, Journal of Electroanalytical Chemistry.

[6]  Arunangshu Ghosh,et al.  Identification of fractional order model for a voltammetric E-tongue system , 2020 .

[7]  M. L. Yola,et al.  Gold Nanoparticles/Two-Dimensional (2D) Hexagonal Boron Nitride Nanosheets Including Diethylstilbestrol Imprinted Polymer: Electrochemical Detection in Urine Samples and Validation , 2018 .

[8]  Peipei Qi,et al.  A novel electrochemical PCB77-binding DNA aptamer biosensor for selective detection of PCB77 , 2016 .

[9]  S. Güney,et al.  Development of an Electrochemical Sensor Based on Covalent Molecular Imprinting for Selective Determination of Bisphenol‐A , 2017 .

[10]  Kun Wang,et al.  A highly sensitive signal-amplified gold nanoparticle-based electrochemical immunosensor for dibutyl phthalate detection. , 2017, Biosensors & bioelectronics.

[11]  P. Kannan,et al.  Graphene interface for detection of resorcinol an endocrine disruptor in solubilized ionic liquid system: Electrochemical and COSMO-RS quantum studies , 2018 .

[12]  Chen Li,et al.  Magnetic nanoparticles coated with a molecularly imprinted polymer doped with manganese-doped ZnS quantum dots for the determination of 2,4,6-trichlorophenol , 2018, Microchimica Acta.

[13]  M. Matoetoe,et al.  Development of a silver functionalised polyaniline electrochemical immunosensor for polychlorinated biphenyls , 2016 .

[14]  Qijin Wan,et al.  Morphology-dependent electrochemistry of FeOOH nanostructures , 2016 .

[15]  S. Basu,et al.  Polyaniline/carbon nanotube-graphite modified electrode sensor for detection of bisphenol A , 2018, Ionics.

[16]  Ronald J. Mascarenhas,et al.  Voltammetric Study and Rapid Quantification of Resorcinol in Hair Dye and Biological Samples Using Ultrasensitive Maghemite/MWCNT Modified Carbon Paste Electrode , 2019, Electroanalysis.

[17]  M. Arbab-Zavar,et al.  On-Chip Electrochemical Sensing of Propylparaben as an Endocrine Disruptor Model Using a Disposable Gold Platform Modified with Phosphomolybdate Doped Polypyrrole and Nanodiamond , 2019, Journal of The Electrochemical Society.

[18]  P. Kannan,et al.  Graphene-amplified femtosensitive aptasensing of estradiol, an endocrine disruptor. , 2018, The Analyst.

[19]  J. Jang,et al.  Fabrication of N-doped multidimensional carbon nanofibers for high-performance cortisol biosensors. , 2019, Biosensors & bioelectronics.

[20]  A. Allafchian,et al.  Flower-Like Self-Assembly of Diphenylalanine for Electrochemical Human Growth Hormone Biosensor , 2018, IEEE Sensors Journal.

[21]  M. Gholivand,et al.  A novel and high sensitive MWCNTs-nickel carbide/hollow fiber-pencil graphite modified electrode for in situ ultra-trace analysis of bisphenol A , 2018 .

[22]  A. Spinelli,et al.  Reduced graphene oxide/gold nanoparticles nanocomposite-modified glassy carbon electrode for determination of endocrine disruptor methylparaben , 2018 .

[23]  Wenjun Yan,et al.  Label-free and highly selective electrochemical aptasensor for detection of PCBs based on nickel hexacyanoferrate nanoparticles/reduced graphene oxides hybrids. , 2019, Biosensors & bioelectronics.

[24]  O. N. Oliveira,et al.  Sensitive detection of estriol hormone in creek water using a sensor platform based on carbon black and silver nanoparticles. , 2017, Talanta.

[25]  S. Senthil Kumar,et al.  Stable and Sensitive Amperometric Determination of Endocrine Disruptor Bisphenol A at Residual Metal Impurities Within SWCNT , 2018 .

[26]  Junsong Liu,et al.  Diamond-based electrochemical aptasensor realizing a femtomolar detection limit of bisphenol A. , 2017, Biosensors & bioelectronics.

[27]  Kangbing Wu,et al.  Simultaneous determination of environmental estrogens: Diethylstilbestrol and estradiol using Cu-BTC frameworks-sensitized electrode. , 2016, Talanta.

[28]  A. Spinelli,et al.  Magnetite nanoparticles/chitosan-modified glassy carbon electrode for non-enzymatic detection of the endocrine disruptor parathion by cathodic square-wave voltammetry , 2018, Journal of Electroanalytical Chemistry.

[29]  S. Ponnaiah,et al.  Ultrasonic energy-assisted in-situ synthesis of Ru0/PANI/g-C3N4 nanocomposite: Application for picomolar-level electrochemical detection of endocrine disruptor (Bisphenol-A) in humans and animals. , 2019, Ultrasonics sonochemistry.

[30]  T. Rocha-Santos,et al.  Development of an electrochemical biosensor for alkylphenol detection. , 2016, Talanta.

[31]  Serdar Abaci,et al.  Highly sensitive electrochemical assay for Bisphenol A detection based on poly (CTAB)/MWCNTs modified pencil graphite electrodes , 2018 .

[32]  R. Gadzała-Kopciuch,et al.  The impact of estrogens on aquatic organisms and methods for their determination , 2017 .

[33]  T. Noguer,et al.  Detection of Bisphenol A in aqueous medium by screen printed carbon electrodes incorporating electrochemical molecularly imprinted polymers. , 2018, Biosensors & bioelectronics.

[34]  A. Spinelli,et al.  Environmentally-friendly in situ plated bismuth-film electrode for the quantification of the endocrine disruptor parathion in skimmed milk. , 2016, Journal of hazardous materials.

[35]  A. Satpati,et al.  An electrochemical Bisphenol F sensor based on ZnO/G nano composite and CTAB surface modified carbon paste electrode architecture. , 2018, Colloids and surfaces. B, Biointerfaces.

[36]  M. He,et al.  Selection of Group-Specific Phthalic Acid Esters Binding DNA Aptamers via Rationally Designed Target Immobilization and Applications for Ultrasensitive and Highly Selective Detection of Phthalic Acid Esters. , 2017, Analytical chemistry.

[37]  Magnus Willander,et al.  Nanoimmunosensor based on ZnO nanorods for ultrasensitive detection of 17β-Estradiol. , 2019, Biosensors & bioelectronics.

[38]  T. A. Silva,et al.  Use of a boron-doped diamond electrode to assess the electrochemical response of the naphthol isomers and to attain their truly simultaneous electroanalytical determination , 2017 .

[39]  Rongfei Zhang,et al.  Voltammetric determination of the endocrine disruptor diethylstilbestrol by using a glassy carbon electrode modified with a composite consisting of platinum nanoparticles and multiwalled carbon nanotubes , 2016, Microchimica Acta.

[40]  D. Tian,et al.  An Electrochemical Sensor for Ultrasensitive Determination the Polychlorinated Biphenyls , 2016 .

[41]  L. Mascaro,et al.  Influence of the different carbon nanotubes on the development of electrochemical sensors for bisphenol A. , 2016, Materials science & engineering. C, Materials for biological applications.

[42]  Claudio Parolo,et al.  Magnetic nanoparticle-molecular imprinted polymer: A new impedimetric sensor for tributyltin detection , 2017 .

[43]  Y. Yun Electrochemical Sensor for Ultrasensitive Determination of Bisphenol A based on Gold Nanoparticles/β-cyclodextrin Functionalized Reduced Graphene Oxide Nanocomposite , 2016, International Journal of Electrochemical Science.

[44]  Xianbo Lu,et al.  Gold Nanoparticles dotted Reduction Graphene Oxide Nanocomposite Based Electrochemical Aptasensor for Selective, Rapid, Sensitive and Congener-Specific PCB77 Detection , 2017, Scientific Reports.

[45]  Sara Bogialli,et al.  Electrochemosensor for Trace Analysis of Perfluorooctanesulfonate in Water Based on a Molecularly Imprinted Poly( o-phenylenediamine) Polymer. , 2018, ACS sensors.

[46]  M. Metzler,et al.  Chemistry of Natural and Anthropogenic Endocrine Active Compounds , 2001 .

[47]  A. Qurashi,et al.  An electrochemical sensor based on fullerene nanorods for the detection of paraben, an endocrine disruptor , 2016 .

[48]  E. Pereira,et al.  Synergic effect of silver nanoparticles and carbon nanotubes on the simultaneous voltammetric determination of hydroquinone, catechol, bisphenol A and phenol , 2017, Microchimica Acta.

[49]  Javier Hernández-Borges,et al.  Dispersive liquid-liquid microextraction for determination of organic analytes , 2010 .

[50]  A. R. Fiorucci,et al.  A new simple electrochemical method for the determination of Bisphenol A using bentonite as modifier. , 2019, Materials science & engineering. C, Materials for biological applications.

[51]  Dun Zhang,et al.  Metastable α-AgVO3 microrods as peroxidase mimetics for colorimetric determination of H2O2 , 2017, Microchimica Acta.

[52]  Yujian He,et al.  Graphene and AuNPs based electrochemical aptasensor for ultrasensitive detection of hydroxylated polychlorinated biphenyl. , 2018, Analytica chimica acta.

[53]  Changlong Hao,et al.  An Ultrasensitive Electrochemical Immunosensor for Nonylphenol Leachate from Instant Noodle Containers in Southeast Asia. , 2019, Chemistry.

[54]  Wan Elina Faradilla Wan Khalid,et al.  A New Sensor for Methyl Paraben Using an Electrode Made of a Cellulose Nanocrystal–Reduced Graphene Oxide Nanocomposite , 2019, Sensors.

[55]  H. El-Desoky,et al.  A First Efficient Voltammetric Approach for Detection of Octreotide, an Octapeptide Analogue of Somatostatin Natural Hormone, in Sandostatin Intramuscular Injection and Human Plasma Based on Modification Free Electrochemical Sensor , 2019, Journal of The Electrochemical Society.

[56]  Longhua Guo,et al.  Highly sensitive aptamer based on electrochemiluminescence biosensor for label-free detection of bisphenol A , 2017, Analytical and Bioanalytical Chemistry.

[57]  P. Campíns-Falcó,et al.  In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters. , 2010, Journal of chromatography. A.