NIRS application in evaluating threaded-fastener driving assembly tasks

Abstract Repetitive use of hand-held power tools, due to their potential to generate forces greater than an operator capacity, is associated with work-related upper extremity musculoskeletal disorders. This laboratory study investigated the effects of power tool-induced torque reaction and work:rest pattern on peripheral circulatory responses during repetitive nutrunner operations. Twenty men completed eight fastener-driving sessions that consisted of two different work:rest patterns of 360 repetitive tasks both at slow- and fast-pace using a pneumatic nutrunner, which was equipped with an instrumented tool handle with a custom-designed force gauge that measures grip force in real time, on a torque reaction assembly joint and a control joint. Near-infrared spectroscopy (NIRS) was simultaneously used to monitor changes in tissue oxygenation and blood volume from flexor digitorum superficialis and extensor digitorum communis. The mean grip force exerted by participants during sessions with no torque buildup was 33% of their maximum voluntary contraction whereas during sessions with torque buildup it was of 57% maximum voluntary contraction. Additionally, throughout a session the rate of changes in grip force decreased more with the latter (−0.007 and −0.022 N/drive, respectively) suggesting considerable effort during torque buildup by the participants. Correspondingly, in the flexor muscles greater deoxygenation was observed than that of extensor muscles for all sessions, suggesting greatest metabolic demand from the flexors during torque buildup. Tissue oxygenation index, representing the dynamic balance between oxygen delivery and oxygen consumption in the tissue was similar during both combinations of pace and work:rest ratios in the flexors. On the contrary, tissue oxygenation index in the extensor region was higher during sessions of slow-pace and work with rest breaks compared to sessions of fast-pace and work with no rest, suggesting that the tool operations with faster work pace and continuous work with no rest breaks results in greatest decrease in oxygen saturation. These findings imply that spectroscopy-derived measures are able to reflect upper extremity physical demands experienced by the tool operators, and therefore NIRS is a useful alternative technique to broaden the understanding of tissue physiological changes resulted from upper extremity activities. Relevance to the industry With advances in technology, more hand-held power tools are repetitively being used on assembly lines in various industries. Although powered tools enhance performance and efficiency, these tools have the potential to result in forces that are often associated with development of musculoskeletal disorders in the upper extremities. This study provided an alternative, non-invasive physiological approach to enhance the understanding of man (hand) and machine (tool) interaction in work productivity factors (e.g., work pace and work:rest patterns).

[1]  Robert G. Radwin,et al.  Handle Dynamics Predictions for Selected Power Hand Tool Applications , 2003, Hum. Factors.

[2]  Patrick G. Dempsey,et al.  Effects of user experience, working posture and joint hardness on powered nutrunner torque reactions , 2007 .

[3]  Yukio Kobayashi,et al.  Tissue oxygenation monitor using NIR spatially resolved spectroscopy , 1999, Photonics West - Biomedical Optics.

[4]  Jia-Hua Lin,et al.  Predicting subjective perceptions of powered tool torque reactions. , 2009, Applied ergonomics.

[5]  T. Armstrong,et al.  Muscle response to pneumatic hand tool torque reaction forces. , 1989, Ergonomics.

[6]  G M Hägg,et al.  Forearm extensor and flexor muscle exertion during simulated gripping work -- an electromyographic study. , 1997, Clinical biomechanics.

[7]  F C T van der Helm,et al.  Muscle oxygen consumption, determined by NIRS, in relation to external force and EMG. , 2003, Journal of biomechanics.

[8]  G M Hägg,et al.  Forearm muscular load and wrist angle among automobile assembly line workers in relation to symptoms. , 1997, Applied ergonomics.

[9]  M. Djupsjöbacka,et al.  Oxygenation, EMG and position sense during computer mouse work. Impact of active versus passive pauses , 2006, European Journal of Applied Physiology.

[10]  Chien-Chi Chang,et al.  Handle displacement and operator responses to pneumatic nutrunner torque buildup. , 2006, Applied ergonomics.

[11]  C Fransson-Hall,et al.  Acceptability of Intermittent Handgrip Contractions Based on Physiological Response , 1994, Human factors.

[12]  D. Chaffin,et al.  A proposed standard procedure for static muscle strength testing. , 1974, American Industrial Hygiene Association journal.

[13]  Toshio Moritani,et al.  Effect of cycling experience and pedal cadence on the near-infrared spectroscopy parameters. , 2002, Medicine and science in sports and exercise.

[14]  T Armstrong,et al.  Muscle responses to simulated torque reactions of hand-held power tools. , 1999, Ergonomics.

[15]  Motoki Kouzaki,et al.  The influence of circulatory difference on muscle oxygenation and fatigue during intermittent static dorsiflexion , 2004, European Journal of Applied Physiology.

[16]  A R Hargens,et al.  Ischemia causes muscle fatigue , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  L Lindbeck,et al.  Pneumatic tool torque reaction: reaction forces, displacement, muscle activity and discomfort in the hand-arm system. , 1993, Applied ergonomics.

[18]  Jia-Hua Lin,et al.  A single-degree-of-freedom dynamic model predicts the range of human responses to impulsive forces produced by power hand tools. , 2003, Journal of biomechanics.

[19]  Chris J. McNeil,et al.  Differential changes in muscle oxygenation between voluntary and stimulated isometric fatigue of human dorsiflexors. , 2006, Journal of applied physiology.

[20]  Svend Erik Mathiassen,et al.  Activity in five muscles during joint securing using pneumatic nutrunners , 2002 .

[21]  A R Hargens,et al.  Forearm muscle oxygenation decreases with low levels of voluntary contraction , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  Anil Mital,et al.  Design, selection and use of hand tools to alleviate trauma of the upper extremities: Part II — The scientific basis (knowledge base) for the guide , 1992 .

[23]  Chien-Chi Chang,et al.  Hand-Handle Interface Force and Torque Measurement System for Pneumatic Assembly Tool Operations: Suggested Enhancement to ISO 6544 , 2007, Journal of occupational and environmental hygiene.

[24]  Patrick G. Dempsey,et al.  Perspectives in Powered Nutrunner Torque Reaction: Handle Displacement and Grip Force , 2003 .

[25]  Markus Nowak,et al.  Muscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans , 1998, European Journal of Applied Physiology and Occupational Physiology.