Mid‐Infrared laser ablation of the cornea: A comparative study

The ablation thresholds and patterns of collateral damage in cornea produced by Er:YAG (2.94 μm) and Er:YSGG (2.79 μm) lasers were measured. Two different pulse durations, 200 μs (normal spiking mode) and 100 ns (Q–switched mode), were used at both wavelengths. In the normal spiking mode, damage zones of 16 ± 2 μm and 39 ± 7 μm and ablation thresholds of 250 ± 20 mJ/cm2 and 420 ± 35 mJ/cm2 were measured at 2.94 μm and 2.79 μm, respectively. In the Q–switched mode, damage zones of 4 ± 2 μm and ablation thresholds of 150 ± 10 mJ/cm2 were found irrespective of the laser used. The similarity between the results using the Er:YAG and Er:YSGG lasers in the Q–switched mode suggest that either laser can be used with equal effectiveness for corneal trephination. © 1992 Wiley‐Liss, Inc.

[1]  R. Srinivasan,et al.  Ablation of polymers and biological tissue by ultraviolet lasers. , 1986, Science.

[2]  C. Puliafito,et al.  Infrared laser surgery of the cornea. Studies with a Raman-shifted neodymium:YAG laser at 2.80 and 2.92 micron. , 1988, Ophthalmology.

[3]  T J Flotte,et al.  Er:YAG laser ablation of tissue: Effect of pulse duration and tissue type on thermal damage , 1989, Lasers in surgery and medicine.

[4]  S. Trokel,et al.  Excimer laser surgery of the cornea. , 1983, American journal of ophthalmology.

[5]  Reginald Birngruber,et al.  Axicon: a new laser beam delivery system for corneal surgery , 1990 .

[6]  G O Waring,et al.  Excimer laser keratectomy for myopia with a rotating-slit delivery system. , 1988, Archives of ophthalmology.

[7]  Peter F. Moulton,et al.  Spectroscopic and laser characteristics of Er,Cr:YSGG , 1988 .

[8]  Jean-Marie A Parel,et al.  Laser surgical unit for photoablative and photothermal keratoplasty , 1991, Photonics West - Lasers and Applications in Science and Engineering.

[9]  F Hillenkamp,et al.  Excimer laser ablation of the cornea and lens. Experimental studies. , 1985, Ophthalmology.

[10]  J. Marshall,et al.  An ultrastructural study of corneal incisions induced by an excimer laser at 193 nm. , 1985, Ophthalmology.

[11]  Martin Frenz,et al.  Instabilities in laser cutting of soft media , 1989 .

[12]  J. Parel,et al.  Potential use of lasers for penetrating keratoplasty , 1989, Journal of cataract and refractive surgery.

[13]  T. Seiler,et al.  NMR-Tomographie des menschlichen Auges , 1986 .

[14]  A L McKenzie,et al.  How far does thermal damage extend beneath the surface of CO2 laser incisions? , 1983, Physics in medicine and biology.

[15]  James J Salz,et al.  Excimer laser radial keratotomy in the living human eye: a preliminary report , 1988 .

[16]  F. L’esperance,et al.  Human excimer laser keratectomy. Short-term histopathology. , 1988, Bulletin of the New York Academy of Medicine.

[17]  J. Parel,et al.  Noncontact trephination of the cornea using a pulsed hydrogen fluoride laser. , 1987, American journal of ophthalmology.

[18]  J. Krauss,et al.  Laser interactions with the cornea. , 1986, Survey of ophthalmology.

[19]  R. Anderson,et al.  Pulsed CO2 laser tissue ablation: Effect of tissue type and pulse duration on thermal damage , 1988, Lasers in surgery and medicine.

[20]  J. Timsit,et al.  Wound healing following excimer laser radial keratotomy , 1988, Journal of cataract and refractive surgery.

[21]  M. Wolbarsht,et al.  Laser surgery: CO2or HF , 1984, IEEE Journal of Quantum Electronics.

[22]  C. Puliafito,et al.  Quantitative and ultrastructural studies of excimer laser ablation of the cornea at 193 and 248 nanometers , 1987, Lasers in surgery and medicine.