Analytical solution of the time-dependent Bloch NMR flow equations: a translational mechanical analysis

Various biological and physiological properties of living tissue can be studied by means of nuclear magnetic resonance techniques. Unfortunately, the basic physics of extracting the relevant information from the solution of Bloch nuclear magnetic resource (NMR) equations to accurately monitor the clinical state of biological systems is still not yet fully understood. Presently, there are no simple closed solutions known to the Bloch equations for a general RF excitation. Therefore the translational mechanical analysis of the Bloch NMR equations presented in this study, which can be taken as definitions of new functions to be studied in detail may reveal very important information from which various NMR flow parameters can be derived. Fortunately, many of the most important but hidden applications of blood flow parameters can be revealed without too much difficulty if appropriate mathematical techniques are used to solve the equations. In this study we are concerned with a mathematical study of the laws of NMR physics from the point of view of translational mechanical theory. The important contribution of this study is that solutions to the Bloch NMR flow equations do always exist and can be found as accurately as desired. We shall restrict our attention to cases where the radio frequency field can be treated by simple analytical methods. First we shall derive a time dependant second-order non-homogeneous linear differential equation from the Bloch NMR equation in term of the equilibrium magnetization M0, RF B1(t) field, T1 and T2 relaxation times. Then, we would develop a general method of solving the differential equation for the cases when RF B1(t)=0, and when RF B1(t)≠0. This allows us to obtain the intrinsic or natural behavior of the NMR system as well as the response of the system under investigation to a specific influence of external force to the system. Specifically, we consider the case where the RF B1 varies harmonically with time. Here the complete motion of the system consists of two parts. The first part describes the motion of the transverse magnetization My in the absence of RF B(t) field. The second part of the motion described by the particular integral of the derived differential equation does not decay with time but continues its periodic behavior indefinitely. The complete motion of the NMR flow system is then quantitatively and qualitatively described.

[1]  O. Simonetti,et al.  Experimental confirmation of phase encoding of instantaneous derivatives of position , 1994, Magnetic resonance in medicine.

[2]  Nuclear magnetic resonance velocity spectra of pulsatile flow in a rigid tube , 1992, Magnetic resonance in medicine.

[3]  V. Govindaraju,et al.  Proton NMR chemical shifts and coupling constants for brain metabolites , 2000, NMR in biomedicine.

[4]  P Boesiger,et al.  FID-acquired-echos (FAcE): a short echo time imaging method for flow artefact suppression. , 1991, Magnetic resonance imaging.

[5]  G. Biessels,et al.  In vivo glucose detection by homonuclear spectral editing , 2000, Magnetic resonance in medicine.

[6]  N J Pelc,et al.  Volume MR angiography: methods to achieve very short echo times. , 1990, Radiology.

[7]  Richard A. Baum,et al.  Magnetic Resonance Angiography: Concepts and Applications , 1995 .

[8]  R Gruetter,et al.  Toward an in vivo neurochemical profile: quantification of 18 metabolites in short-echo-time (1)H NMR spectra of the rat brain. , 1999, Journal of magnetic resonance.

[9]  Matthew P. Augustine,et al.  Radiation damping with inhomogeneous broadening: limitations of the single bloch vector model , 2001 .

[10]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[11]  Á. Demeter,et al.  Radiation damping diagnostics , 1999 .

[12]  Brian D. Ross,et al.  Magnetic Resonance Spectroscopy Diagnosis of Neurological Diseases , 1999 .

[13]  G B Matson,et al.  Measurement of chemical shifts and coupling constants for glutamate and glutamine , 1998, Magnetic resonance in medicine.

[14]  René M. Botnar,et al.  Quantification of blood flow patterns in human vessels by magnetic resonance imaging. , 1996, Technology and health care : official journal of the European Society for Engineering and Medicine.

[15]  A. Fenster,et al.  Computer‐controlled flow simulator for MR flow studies , 1992, Journal of magnetic resonance imaging : JMRI.

[16]  R. Pettigrew,et al.  Effects of acceleration on the accuracy of MR phase velocity measurements , 1992, Journal of magnetic resonance imaging : JMRI.

[17]  O Henriksen,et al.  Quantification of complex flow using MR phase imaging--a study of parameters influencing the phase/velocity relation. , 1992, Magnetic resonance imaging.

[18]  O. Awojoyogbe,et al.  A mathematical model of Bloch NMR equations for quantitative analysis of blood flow in blood vessels of changing cross-section—PART II , 2003 .

[19]  E. Hahn,et al.  Three component spin echo generation by radiation damping , 1997 .

[20]  D Meier,et al.  Quantitative flow measurements on phantoms and on blood vessels with MR , 1988, Magnetic resonance in medicine.

[21]  Matthew P. Augustine,et al.  THREE-COMPONENT SPIN ECHOES , 1998 .

[22]  O. Awojoyogbe,et al.  A mathematical model of the Bloch NMR equations for quantitative analysis of blood flow in blood vessels with changing cross-section-I , 2002 .

[23]  Douglas L. Rothman,et al.  In vivo detection and quantification of scalar coupled H NMR resonances , 2001 .

[24]  P Boesiger,et al.  Detection of glutathione in the human brain in vivo by means of double quantum coherence filtering , 1999, Magnetic resonance in medicine.

[25]  D N Firmin,et al.  The application of phase shifts in NMR for flow measurement , 1990, Magnetic resonance in medicine.

[26]  P Boesiger,et al.  Visualization and quantification of the human blood flow by magnetic resonance imaging. , 1992, Journal of biomechanics.

[27]  M Kouwenhoven,et al.  Motion Induced Phase Shifts in MR: Acceleration Effects in Quantitative Flow Measurements—A Reconsideration , 1995, Magnetic resonance in medicine.

[28]  K. Ogawa,et al.  Three-dimensional velocity measurement of complex interstitial flows through water-saturated porous media by the tagging method in the MRI technique , 2001 .

[29]  D N Firmin,et al.  Valve and great vessel stenosis: assessment with MR jet velocity mapping. , 1991, Radiology.

[30]  D. Vortmeyer,et al.  Measured and modeled superficial flow profiles in packed beds with liquid flow , 1998 .

[31]  N J Pelc,et al.  Minimizing TE in moment‐nulled or flow‐encoded two‐and three‐dimensional gradient‐echo imaging , 1992, Journal of magnetic resonance imaging : JMRI.