Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System

This paper addresses the harmonic stability caused by the interactions among the wideband control of power converters and passive components in an ac power-electronics-based power system. The impedance-based analytical approach is employed and expanded to a meshed and balanced three-phase network which is dominated by multiple current- and voltage-controlled inverters with LCL- and LC-filters. A method of deriving the impedance ratios for the different inverters is proposed by means of the nodal admittance matrix. Thus, the contribution of each inverter to the harmonic stability of the power system can be readily predicted through Nyquist diagrams. Time-domain simulations and experimental tests on a three-inverter-based power system are presented. The results validate the effectiveness of the theoretical approach.

[1]  T.C. Green,et al.  Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid , 2007, IEEE Transactions on Power Electronics.

[2]  S. Lefebvre Tuning of Stabilizers in Multimachine Power Systems , 1983, IEEE Power Engineering Review.

[3]  B. Dube,et al.  Control system analysis and design for an aerogenerator with eigenvalue methods , 1988 .

[4]  José M. Espí,et al.  Wind Turbine Generation System With Optimized DC-Link Design and Control , 2013, IEEE Transactions on Industrial Electronics.

[5]  Shuai Jiang,et al.  Resonance Issues and Damping Techniques for Grid-Connected Inverters With Long Transmission Cable , 2014, IEEE Transactions on Power Electronics.

[6]  Victor Cardenas,et al.  Digital Control in Power Electronics , 2006, 2006 IEEE International Power Electronics Congress.

[7]  Ernane Antônio Alves Coelho,et al.  Small signal stability for parallel connected inverters in stand-alone AC supply systems , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[8]  Timothy C. Green,et al.  Dynamic Stability of a Microgrid With an Active Load , 2013, IEEE Transactions on Power Electronics.

[9]  D. Boroyevich,et al.  Small-signal modeling and control of three-phase PWM converters , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[10]  R. D. Middlebrook,et al.  Input filter considerations in design and application of switching regulators. , 1976 .

[11]  M. Liserre,et al.  An active damper for stabilizing power electronics-based AC systems , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[12]  Bo Wen,et al.  Experimental verification of the Generalized Nyquist stability criterion for balanced three-phase ac systems in the presence of constant power loads , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[13]  Paolo Mattavelli,et al.  Analysis of Parallel Operation of Uninterruptible Power Supplies Loaded Through Long Wiring Cables , 2009, IEEE Transactions on Power Electronics.

[14]  S. Lefebvre,et al.  Decentralized Power Modulation of Multiterminal HVDC Systems , 1981, IEEE Transactions on Power Apparatus and Systems.

[15]  Robert Turner,et al.  Stability and Bandwidth Implications of Digitally Controlled Grid-Connected Parallel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[16]  Jian Sun,et al.  Small-Signal Methods for AC Distributed Power Systems–A Review , 2009, IEEE Transactions on Power Electronics.

[17]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[18]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[19]  J. D. Ainsworth,et al.  Harmonic instability between controlled static convertors and a.c. networks , 1967 .

[20]  Zhe Chen,et al.  Autonomous control of inverter-interfaced Distributed Generation units for harmonic current filtering and resonance damping in an islanded microgrid , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[21]  John Shen,et al.  Series and Parallel Resonance Problem of Wideband Frequency Harmonic and Its Elimination Strategy , 2014, IEEE Transactions on Power Electronics.

[22]  E. Mollerstedt,et al.  Out of control because of harmonics-an analysis of the harmonic response of an inverter locomotive , 2000, IEEE Control Systems.

[23]  Tuomas Messo,et al.  Determining the Value of DC-Link Capacitance to Ensure Stable Operation of a Three-Phase Photovoltaic Inverter , 2014, IEEE Transactions on Power Electronics.

[24]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[25]  Robert Turner,et al.  A Case Study on the Application of the Nyquist Stability Criterion as Applied to Interconnected Loads and Sources on Grids , 2013, IEEE Transactions on Industrial Electronics.

[26]  Zhengyou He,et al.  Harmonic Resonance Assessment to Traction Power-Supply System Considering Train Model in China High-Speed Railway , 2014, IEEE Transactions on Power Delivery.

[27]  Jin-Woo Jung,et al.  Stability Analysis of Load Sharing Control for Distributed Generation Systems , 2007, IEEE Transactions on Energy Conversion.

[28]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[29]  T. Messo,et al.  Modeling the grid synchronization induced negative-resistor-like behavior in the output impedance of a three-phase photovoltaic inverter , 2013, 2013 4th IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[30]  Frede Blaabjerg,et al.  Autonomous Control of Inverter-Interfaced Distributed Generation Units for Harmonic Current Filtering and Resonance Damping in an Islanded Microgrid , 2012, IEEE Transactions on Industry Applications.

[31]  Hanmin Lee,et al.  Harmonic analysis of the korean high-speed railway using the eight-port representation model , 2006, IEEE Transactions on Power Delivery.

[32]  S. Bolognani,et al.  Reactive Power Ancillary Service by Constant Power Loads in Distributed AC Systems , 2013, IEEE Transactions on Power Delivery.

[33]  I. Postlethwaite,et al.  The generalized Nyquist stability criterion and multivariable root loci , 1977 .

[34]  M. Belkhayat,et al.  Stability criteria for AC power systems with regulated loads , 1997 .

[35]  T.C. Green,et al.  Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters , 2008, IEEE Transactions on Power Electronics.

[36]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[37]  Massimo Bongiorno,et al.  Frequency-domain passivity-based current controller design , 2008 .

[38]  D. Mukhedkar,et al.  Comparative analysis and study of the dynamic stability of AC/DC systems , 1988 .

[39]  B. Davat,et al.  Stability analysis of power systems by the generalised Nyquist criterion , 1994 .

[40]  Claus Leth Bak,et al.  Wind turbine converter control interaction with complex wind farm systems , 2013 .

[41]  Bangyin Liu,et al.  Stability Analysis of Grid-Connected Inverter With LCL Filter Adopting a Digital Single-Loop Controller With Inherent Damping Characteristic , 2013, IEEE Transactions on Industrial Informatics.

[42]  Babu Narayanan,et al.  POWER SYSTEM STABILITY AND CONTROL , 2015 .

[43]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[44]  P. Brogan The stability of multiple, high power, active front end voltage sourced converters when connected to wind farm collector systems , 2010 .

[45]  Bo Wen,et al.  Influence of phase-locked loop on input admittance of three-phase voltage-source converters , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[46]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[47]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[48]  Zhe Chen,et al.  Resonance analysis in parallel voltage-controlled Distributed Generation inverters , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[49]  Fei Wang,et al.  Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters , 2011, IEEE Transactions on Power Electronics.