Determination of chemical oxygen demand in fresh waters using flow injection with on-line UV-photocatalytic oxidation and spectrophotometric detection.

A flow injection manifold incorporating UV-photocatalytic oxidation for the determination of chemical oxygen demand (COD) in freshwater is reported. The method utilises the UV-photocatalytic oxidation of organic compounds instead of conventional heating (used in the standard method), with acidified potassium permanganate as the oxidant. Sodium oxalate, d-glucose and potassium hydrogen phthalate were used as COD standards. A 100 microL sample solution was injected into a 0.3 mol L(-1) H2SO4 carrier stream containing 0.1 mol L(-1) (NH4)2SO4, merged with a permanganate solution (8 x 10(-4) mol L(-1)) and passed through a 250 cm FEP (fluoroethylene polymer) photo-reaction coil wound around a 15 W UV lamp. The sample throughput was 30 h(-1), with an LOD (blank plus 3sigma) of 0.5 mg COD L(-1) and a linear range of 0.5-50 mg COD L(-1) (D-glucose, r2 = 0.9966). The method had good precision with relative standard deviations of 2.7% at 5 mg COD L(-1) and 1.2% at 20 mg COD L(-1) (n = 12) for glucose. Results for a COD certified reference material (QC Demand Quality Control Standard) were in good agreement with the certified COD value. Recovery from Tamar River water samples for all three COD standards was 83.0-111.0% and the COD values determined were in good agreement with those of a permanganate index reference method.

[1]  V. Montiel,et al.  Development of a Fully Automatic Microwave Assisted Chemical Oxygen Demand (COD) Measurement Device , 2003 .

[2]  M. Al-Malack,et al.  Alternative Method for Determination of the Chemical Oxygen Demand for Colloidal Polymeric Wastewater , 1997, Bulletin of environmental contamination and toxicology.

[3]  G. Low,et al.  Flow-injection determination of organic contaminants in water using an ultraviolet-mediated titanium dioxide film reactor , 1990 .

[4]  A. Canals,et al.  Rapid determination of chemical oxygen demand by a semi-automated method based on microwave sample digestion, chromium(VI) organic solvent extraction and flame atomic absorption spectrometry , 1998 .

[5]  I. Karube,et al.  Relationship between theoretical oxygen demand and photocatalytic chemical oxygen demand for specific classes of organic chemicals , 2000 .

[6]  Michal Green,et al.  Potentiometric measurement of chemical oxygen demand , 1997 .

[7]  A. Canals,et al.  New ultrasound assisted chemical oxygen demand determination. , 2002, Ultrasonics sonochemistry.

[8]  A. Canals,et al.  Flow injection method for the rapid determination of Chemical Oxygen Demand based on microwave digestion and chromium speciation in Flame Atomic Absorption Spectrometry , 1996 .

[9]  I. Karube,et al.  Photocatalytic sensor for the determination of chemical oxygen demand using flow injection analysis , 2001 .

[10]  C. Richard,et al.  Photocatalytic transformation of aromatic compounds in aqueous zinc oxide suspensions: effect of substrate concentration on the distribution of products , 1997 .

[11]  T. Korenaga,et al.  The determination of chemical oxygen demand in waste-waters with dichromate by flow injection analysis , 1982 .

[12]  J. Houser Semimicro Determination of COD Employing Microwave Digestion , 2003 .

[13]  Kyung-Yup Hwang,et al.  Correction of hydrogen peroxide interference on standard chemical oxygen demand test , 1999 .

[14]  T. Korenaga,et al.  Continuous-flow injection analysis of aqueous environmental samples for chemical oxygen demand , 1981 .

[15]  M. Dular,et al.  Use of flow injection analysis based on iodometry for automation of dissolved oxygen (Winkler method) and chemical oxygen demand (dichromate method) determinations , 1988 .

[16]  J. Golimowski,et al.  UV-photooxidation as pretreatment step in inorganic analysis of environmental samples , 1996 .

[17]  P. Pope,et al.  Miniaturized closed reflux, colorimetric method for the determination of chemical oxygen demand , 2000 .

[18]  Xiao-ru Wang,et al.  Measurement of chemical oxygen demand (COD) in natural water samples by flow injection ozonation chemiluminescence (FI-CL) technique. , 2004, Journal of environmental monitoring : JEM.

[19]  M. Valle,et al.  Rapid determination of chemical oxygen demand using a focused microwave heating system featuring temperature control , 2003 .

[20]  Dennis C. Johnson,et al.  The coulometric determination of chemical oxygen demand , 1997 .

[21]  Isao Karube,et al.  A flow method with photocatalytic oxidation of dissolved organic matter using a solid-phase (TiO2) reactor followed by amperometric detection of consumed oxygen. , 2002, Analytical chemistry.

[22]  S. Ai,et al.  Study on photocatalytic oxidation for determination of chemical oxygen demand using a nano-TiO2–K2Cr2O7 system , 2004 .

[23]  K. Mopper,et al.  Determination of photochemically produced hydroxyl radicals in seawater and freshwater , 1990 .

[24]  Yu-Ying Qin,et al.  Chemical oxygen demand determination in environmental waters by mixed-acid digestion and single sweep polarography , 2000 .