New automated wavelet analytical system with a cellular phone for recording intercellular phone remote transmitted bileaflet valve sound
暂无分享,去创建一个
Kenji Sugiki | Hiroshi Sugiki | Norihiko Shiiya | Yoshiro Matsui | Takashi Sugiki | Y. Matsui | H. Sugiki | N. Shiiya | Takashi Sugiki | K. Sugiki
[1] M. Jones,et al. Doppler color flow evaluation of prosthetic mitral valves: experimental epicardial studies. , 1989, Journal of the American College of Cardiology.
[2] A Gomi. Improved method for the wave and frequency analysis of the various prosthetic heart valve sounds , 1989 .
[3] J. Ross,et al. Clinical and echocardiographic evaluation of the St. Jude cardiac valve prosthesis: follow-up of 126 patients. , 1984, Journal of the American College of Cardiology.
[4] Hiroshi Sugiki,et al. Bileaflet mechanical valve sound analysis using a continuous wavelet transform , 2006, Journal of Artificial Organs.
[5] J. Copeland,et al. Acoustic analysis of the closing sounds of bileaflet prosthetic valves in a sheep model. , 1991, The Journal of thoracic and cardiovascular surgery.
[6] Peter Johansen,et al. Spectral characteristics of mechanical heart valve closing sounds. , 2002, The Journal of heart valve disease.
[7] J. Gibbs,et al. Doppler ultrasound of normally functioning mechanical mitral and aortic valve prostheses. , 1988, International journal of cardiology.
[8] Shigemi Hosogaya,et al. [Allowable limits of analytical error which can guarantee the reliability of reference intervals for interpretation of clinical laboratory data]. , 2008, Rinsho byori. The Japanese journal of clinical pathology.
[9] D. B. Tonks,et al. A study of the accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories. , 1963, Clinical chemistry.
[10] B. Segal,et al. Spectroanalytic evaluation of aortic prosthetic valves. , 1974, Chest.
[11] H. Allen,et al. Asynchronous leaflet closure in the normally functioning bileaflet mechanical valve. , 1990, American heart journal.
[12] S. W. Halpern,et al. Noninvasive in vivo and in vitro study of the St. Jude mitral valve prosthesis. Evaluation using two dimensional and M mode echocardiography, phonocardiography and cinefluoroscopy. , 1982, The American journal of cardiology.
[13] S Nitta,et al. Sound spectroanalytic diagnosis of malfunctioning prosthetic heart valve. , 1977, The Tohoku journal of experimental medicine.
[14] H. Sustaita,et al. An appreciation of the new St. Jude valvular prosthesis. , 1981, The Journal of thoracic and cardiovascular surgery.
[15] E. K. Harris,et al. Biological and analytic components of variation in long-term studies of serum constituents in normal subjects. 3. Physiological and medical implications. , 1970, Clinical chemistry.
[16] Y. Matsui,et al. Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve , 2008, Journal of Artificial Organs.
[17] E. K. Harris,et al. Biological and analytic components of variation in long-term studies of serum constituents in normal subjects. II. Estimating biological components of variation. , 1971, Clinical chemistry.
[18] Kenji Matsuzaki,et al. Wavelet analysis of bileaflet mechanical valve sounds , 2006, Journal of Artificial Organs.
[19] M Tanaka,et al. Real-time sound spectroanalysis for diagnosis of malfunctioning prosthetic valves. , 1980, The Journal of thoracic and cardiovascular surgery.
[20] George Z. Williams,et al. Biological and Analytic Components of Variation in Long-Term Studies of Serum Constituents in Normal Subjects I. Objectives, Subject Selection, Laboratory Procedures, and Estimation of Analytic Deviation , 1970 .