Platinized aligned carbon nanotube-sheathed carbon fiber microelectrodes for in vivo amperometric monitoring of oxygen.

The abnormal level of O2 could disturb various neurochemical processes and even induce neural injury and brain dysfunction. In order to assess critical roles of O2 in the neurochemical processes, it is essential to perform in vivo monitoring of the dynamic changes of O2. In this study, we develop a new electrochemical method for selectively monitoring O2 in vivo, using platinized vertically aligned carbon nanotube (VACNT)-sheathed carbon fibers (Pt/VACNT-CFs) as the electrodes. The VACNT-sheathed CFs (VACNT-CFs) are produced via the pyrolysis of iron phthalocyanine (FePc) on the surface of CFs, followed by electrochemical deposition of platinum nanoparticles to form Pt/VACNT-CFs. The resulting Pt/VACNT-CF microelectrodes exhibit fast overall kinetics for the O2 reduction via a four-electron reduction process without the formation of toxic H2O2 intermediate. Consequently, effective and selective electrochemical methods are developed for the measurements of O2 in rat brain with the Pt/VACNT-CF microelectrodes, even in the presence of some species at their physiological levels, such as ascorbic acid, dopamine, uric acid, 5-hydroxytryptamine, and of the O2 fluctuation in rat brain in the early stage of global cerebral ischemia/reperfusion, mild hyperoxia, and hypoxia induced by exposing the animal, for a short time, to O2 and N2, respectively, and hindfeet pinch. The use of VACNT-CF as the support for Pt effectively improves the stability of Pt, as compared with the bare CF support, while the FePc pyrolysis ensures the VACNT-CFs to be reproducibly produced. Thus, this study offers a novel and reliable strategy for preparing new microelectrodes for in vivo monitoring of O2 in various physiological processes with a high sensitivity and selectivity.

[1]  R. Neumar,et al.  Brain ischemia and reperfusion: molecular mechanisms of neuronal injury , 2000, Journal of the Neurological Sciences.

[2]  Anusorn Kongkanand,et al.  Single-wall carbon nanotubes supported platinum nanoparticles with improved electrocatalytic activity for oxygen reduction reaction. , 2006, Langmuir : the ACS journal of surfaces and colloids.

[3]  N. Rosenzweig,et al.  Molecular oxygen-sensitive fluorescent lipobeads for intracellular oxygen measurements in murine macrophages. , 2001, Analytical chemistry.

[4]  Fiachra B. Bolger,et al.  An in vitro characterisation comparing carbon paste and Pt microelectrodes for real-time detection of brain tissue oxygen. , 2011, The Analyst.

[5]  E. Hall,et al.  Central nervous system trauma and stroke. II. Physiological and pharmacological evidence for involvement of oxygen radicals and lipid peroxidation. , 1989, Free radical biology & medicine.

[6]  D. Gough,et al.  In vitro stability of an oxygen sensor. , 1987, Analytical chemistry.

[7]  J. Pouysségur,et al.  Oxygen, a source of life and stress , 2007, FEBS letters.

[8]  P. Trayhurn Hypoxia and adipose tissue function and dysfunction in obesity. , 2013, Physiological reviews.

[9]  L. Qu,et al.  Carbon microfibers sheathed with aligned carbon nanotubes: towards multidimensional, multicomponent, and multifunctional nanomaterials. , 2006, Small.

[10]  Wenzheng Li,et al.  Supportless Pt and PtPd nanotubes as electrocatalysts for oxygen-reduction reactions. , 2007, Angewandte Chemie.

[11]  M. Moskowitz,et al.  Pathobiology of ischaemic stroke: an integrated view , 1999, Trends in Neurosciences.

[12]  Lei Su,et al.  Electrochemistry and Electroanalytical Applications of Carbon Nanotubes: A Review , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[13]  L. Greenfield,et al.  Ischemia-induced increase in microvascular phosphodiesterase 4D expression in rat hippocampus associated with blood brain barrier permeability: effect of age. , 2012, ACS chemical neuroscience.

[14]  N. Rost Clinical neurogenetics: stroke. , 2013, Neurologic clinics.

[15]  I A Silver,et al.  Tissue oxygen tension and brain sensitivity to hypoxia. , 2001, Respiration physiology.

[16]  D. Ferriero,et al.  Differential vulnerability of immature murine neurons to oxygen-glucose deprivation , 2004, Experimental Neurology.

[17]  Wei Zheng,et al.  Carbon‐Nanotube‐Based Glucose/O2 Biofuel Cells , 2006 .

[18]  D. Attwell,et al.  Glutamate release in severe brain ischaemia is mainly by reversed uptake , 2000, Nature.

[19]  T. Ohsaka,et al.  Online electrochemical monitoring of dynamic change of hippocampal ascorbate: toward a platform for in vivo evaluation of antioxidant neuroprotective efficiency against cerebral ischemia injury. , 2013, Analytical chemistry.

[20]  P. Vadgama,et al.  O2 microsensors for minimally invasive tissue monitoring , 2004, Journal of The Royal Society Interface.

[21]  H. Swartz Measuring real levels of oxygen in vivo: opportunities and challenges. , 2001, Biochemical Society transactions.

[22]  C. Rosen,et al.  The science of cerebral ischemia and the quest for neuroprotection: navigating past failure to future success. , 2013, Journal of neurosurgery.

[23]  Yi Chen,et al.  Electrostatic layer-by-layer assembled carbon nanotube multilayer film and its electrocatalytic activity for O2 reduction. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[24]  P. Horn,et al.  Continuous monitoring of regional cerebral blood flow during temporary arterial occlusion in aneurysm surgery. , 2001, Journal of neurosurgery.

[25]  Giammario Calia,et al.  Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats. , 2013, Analytical chemistry.

[26]  R. Koehler,et al.  Oxygen radical mechanisms of brain injury following ischemia and reperfusion. , 1991, Journal of applied physiology.

[27]  Tianyan You,et al.  Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide. , 2003, Analytical chemistry.

[28]  N. Kulagina,et al.  Monitoring hydrogen peroxide in the extracellular space of the brain with amperometric microsensors. , 2003, Analytical chemistry.

[29]  D. Rossi,et al.  Astrocyte metabolism and signaling during brain ischemia , 2007, Nature Neuroscience.

[30]  R. Wightman Probing Cellular Chemistry in Biological Systems with Microelectrodes , 2006, Science.

[31]  F. Du,et al.  Nitrogen-Doped Carbon Nanotube Arrays with High Electrocatalytic Activity for Oxygen Reduction , 2009, Science.

[32]  Zimmerman Jb,et al.  Simultaneous electrochemical measurements of oxygen and dopamine in vivo. , 1991 .

[33]  Ling Xiang,et al.  Vertically aligned carbon nanotube-sheathed carbon fibers as pristine microelectrodes for selective monitoring of ascorbate in vivo. , 2014, Analytical chemistry.

[34]  David S. C. Lee,et al.  Using near-infrared spectroscopy to measure cerebral metabolic rate of oxygen under multiple levels of arterial oxygenation in piglets. , 2010, Journal of applied physiology.

[35]  A. Faden Pharmacotherapy in spinal cord injury: a critical review of recent developments. , 1987, Clinical neuropharmacology.

[36]  C. Kieda,et al.  Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia , 2011, Journal of cellular and molecular medicine.

[37]  Kevin R Ward,et al.  Oxygenation monitoring of tissue vasculature by resonance Raman spectroscopy. , 2007, Analytical chemistry.

[38]  J. Baek,et al.  Controlled growth and modification of vertically-aligned carbon nanotubes for multifunctional applications , 2010 .

[39]  H. Kontos,et al.  Superoxide production in experimental brain injury. , 1986, Journal of neurosurgery.

[40]  J. H. Chen,et al.  High dispersion and electrocatalytic properties of platinum on well-aligned carbon nanotube arrays , 2004 .

[41]  Xiaolan Chai,et al.  A two-channel ratiometric electrochemical biosensor for in vivo monitoring of copper ions in a rat brain using gold truncated octahedral microcages. , 2013, Angewandte Chemie.

[42]  Itamar Willner,et al.  Biomolecule-functionalized carbon nanotubes: applications in nanobioelectronics. , 2004, Chemphyschem : a European journal of chemical physics and physical chemistry.

[43]  Lisa J. Mellander,et al.  Evaluating the diffusion coefficient of dopamine at the cell surface during amperometric detection: disk vs ring microelectrodes. , 2013, Analytical chemistry.

[44]  P. Osborne,et al.  Hippocampal and Striatal Blood Flow During Behavior in Rats: Chronic Laser Doppler Flowmetry Study , 1997, Physiology & Behavior.

[45]  K. Liu,et al.  Cerebral tissue oxygenation and oxidative brain injury during ischemia and reperfusion. , 2007, Frontiers in bioscience : a journal and virtual library.

[46]  M. Bron,et al.  High stability of low Pt loading high surface area electrocatalysts supported on functionalized carbon nanotubes , 2013 .

[47]  K. Liu,et al.  Interstitial pO2 in Ischemic Penumbra and Core are Differentially Affected following Transient Focal Cerebral Ischemia in Rats , 2004, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[48]  A. Ewing,et al.  Voltammetric measurement of oxygen in single neurons using platinized carbon ring electrodes. , 1992, Analytical chemistry.

[49]  R. Wightman,et al.  Correlation of local changes in extracellular oxygen and pH that accompany dopaminergic terminal activity in the rat caudate–putamen , 2003, Journal of neurochemistry.

[50]  Y Li,et al.  Oxygen‐sensing microdialysis probe for in vivo use , 2001, Journal of neuroscience research.

[51]  D. Choi,et al.  Brain tissue responses to ischemia. , 2000, The Journal of clinical investigation.

[52]  R. McCreery,et al.  Advanced carbon electrode materials for molecular electrochemistry. , 2008, Chemical reviews.

[53]  M. Rice H2O2: a dynamic neuromodulator. , 2011, The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry.

[54]  Roger Springett,et al.  Measurements of oxygen in vivo: overview and perspectives on methods to measure oxygen within cells and tissues. , 2007, Antioxidants & redox signaling.

[55]  Shouheng Sun,et al.  A general approach to the size- and shape-controlled synthesis of platinum nanoparticles and their catalytic reduction of oxygen. , 2008, Angewandte Chemie.

[56]  G Marchal,et al.  Early Postischemic Hyperperfusion: Pathophysiologic Insights from Positron Emission Tomography , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[57]  R. Woods,et al.  Diffusion-perfusion MRI characterization of post-recanalization hyperperfusion in humans , 2001, Neurology.

[58]  R. Busto,et al.  Glutamate Release and Free Radical Production Following Brain Injury: Effects of Posttraumatic Hypothermia , 1995, Journal of neurochemistry.

[59]  L. Sombers,et al.  Voltammetric detection of hydrogen peroxide at carbon fiber microelectrodes. , 2010, Analytical chemistry.

[60]  G. S. Wilson,et al.  Enzyme-based biosensors for in vivo measurements. , 2000, Chemical reviews.

[61]  Giammario Calia,et al.  Real-time monitoring of brain tissue oxygen using a miniaturized biotelemetric device implanted in freely moving rats. , 2009, Analytical chemistry.

[62]  K. Mineura,et al.  A new technique for the mapping of oxygen tension on the brain surface , 2005, Journal of the Neurological Sciences.

[63]  John P. Lowry,et al.  Brain Tissue Oxygen: In Vivo Monitoring with Carbon Paste Electrodes , 2005, Sensors (Basel, Switzerland).

[64]  L. Sombers,et al.  Quantitation of hydrogen peroxide fluctuations and their modulation of dopamine dynamics in the rat dorsal striatum using fast-scan cyclic voltammetry. , 2013, ACS chemical neuroscience.

[65]  R. Freeman,et al.  Single-Neuron Activity and Tissue Oxygenation in the Cerebral Cortex , 2003, Science.

[66]  Christian Amatore,et al.  Electrochemical monitoring of single cell secretion: vesicular exocytosis and oxidative stress. , 2008, Chemical reviews.

[67]  B. J. Venton,et al.  Rapid, sensitive detection of neurotransmitters at microelectrodes modified with self-assembled SWCNT forests. , 2012, Analytical chemistry.

[68]  K. Sasaki,et al.  Stabilization of Platinum Oxygen-Reduction Electrocatalysts Using Gold Clusters , 2007, Science.

[69]  Lei Su,et al.  Continuous on-line monitoring of extracellular ascorbate depletion in the rat striatum induced by global ischemia with carbon nanotube-modified glassy carbon electrode integrated into a thin-layer radial flow cell. , 2005, Analytical chemistry.

[70]  Filip Braet,et al.  Carbon nanomaterials in biosensors: should you use nanotubes or graphene? , 2010, Angewandte Chemie.

[71]  R. Adams,et al.  Probing brain chemistry with electroanalytical techniques. , 1976, Analytical chemistry.

[72]  Restricted diffusion of dopamine in the rat dorsal striatum. , 2013, ACS chemical neuroscience.

[73]  S. Singh,et al.  Differential temporal response of hippocampus, cortex and cerebellum to hypobaric hypoxia: A biochemical approach , 2007, Neurochemistry International.

[74]  G. S. Wilson,et al.  In-vivo electrochemistry: what can we learn about living systems? , 2008, Chemical reviews.

[75]  M. Fillenz,et al.  Characterization of carbon paste electrodes in vitro for simultaneous amperometric measurement of changes in oxygen and ascorbic acid concentrations in vivo. , 1996, The Analyst.

[76]  A. Bhardwaj,et al.  Mechanisms of brain injury after global cerebral ischemia. , 2006, Neurologic clinics.

[77]  D. Barbier,et al.  Immobilization method to preserve enzyme specificity in biosensors: consequences for brain glutamate detection. , 2013, Analytical chemistry.

[78]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[79]  Prashant V. Kamat,et al.  Electrocatalytically Active Graphene-Platinum Nanocomposites. Role of 2-D Carbon Support in PEM Fuel Cells , 2009 .

[80]  Liming Dai,et al.  Patterned Growth and Contact Transfer of Well-Aligned Carbon Nanotube Films , 1999 .

[81]  A. Andrews,et al.  The real catecholamine content of secretory vesicles in the CNS revealed by electrochemical cytometry , 2013, Scientific Reports.

[82]  Ping Yu,et al.  In vivo electrochemical monitoring of the change of cochlear perilymph ascorbate during salicylate-induced tinnitus. , 2012, Analytical chemistry.

[83]  R. Kennedy,et al.  Oxygen microsensor and its application to single cells and mouse pancreatic islets. , 1999, Analytical chemistry.

[84]  Kun Liu,et al.  Carbon nanotube-modified carbon fiber microelectrodes for in vivo voltammetric measurement of ascorbic acid in rat brain. , 2007, Analytical chemistry.

[85]  L. C. Clark,et al.  Chronically implanted polarographic electrodes. , 1958, Journal of applied physiology.

[86]  A S Bondarenko,et al.  Alloys of platinum and early transition metals as oxygen reduction electrocatalysts. , 2009, Nature chemistry.

[87]  Fiachra B. Bolger,et al.  An investigation of hypofrontality in an animal model of schizophrenia using real-time microelectrochemical sensors for glucose, oxygen, and nitric oxide. , 2013, ACS chemical neuroscience.

[88]  W. Pulsinelli,et al.  Temporal thresholds for neocortical infarction in rats subjected to reversible focal cerebral ischemia. , 1991, Stroke.

[89]  P. Gorelick Stroke Prevention Therapy Beyond Antithrombotics: Unifying Mechanisms in Ischemic Stroke Pathogenesis and Implications for Therapy: An Invited Review , 2002, Stroke.

[90]  J. Lowry,et al.  Development and characterization in vitro of a catalase-based biosensor for hydrogen peroxide monitoring. , 2007, Biosensors & bioelectronics.

[91]  Ping Yu,et al.  Rational design of surface/interface chemistry for quantitative in vivo monitoring of brain chemistry. , 2012, Accounts of chemical research.