Fault location observability analysis and optimal meter placement based on voltage measurements

Various transmission line fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for power networks where digital relays have not yet been widely adopted and measuring devices such as digital fault recorders are deployed for monitoring purposes. A sample power network has been employed to illustrate the proposed method.

[1]  P. A. Crossley,et al.  Application of a Wide Area Backup Protection Expert System to Prevent Cascading Outages , 2002, IEEE Power Engineering Review.

[2]  M. S. Sachdev,et al.  A technique for estimating transmission line fault locations from digital impedance relay measurements , 1988 .

[3]  Yuan Liao,et al.  Fault Location for Single-Circuit Line Based on Bus-Impedance Matrix Utilizing Voltage Measurements , 2008, IEEE Transactions on Power Delivery.

[4]  S.H. Horowitz,et al.  Protection issues during system restoration , 2005, IEEE Transactions on Power Delivery.

[5]  Nicholas Jenkins,et al.  Automatic fault location on distribution network using voltage sags measurements , 2005 .

[6]  S.M. Brahma,et al.  Fault location scheme for a multi-terminal transmission line using synchronized Voltage measurements , 2005, IEEE Transactions on Power Delivery.

[7]  Yuan Liao Fault Location Using Sparse Voltage Measurements , 2007, 2007 39th North American Power Symposium.

[8]  A. Abur,et al.  Fault Location Using Voltage Measurements , 2001, IEEE Power Engineering Review.

[9]  Stefania Conti,et al.  Procedures for fault location and isolation to solve protection selectivity problems in MV distribution networks with dispersed generation , 2009 .

[10]  M.H.J. Bollen,et al.  An optimal monitoring program for obtaining Voltage sag system indexes , 2006, IEEE Transactions on Power Systems.

[11]  J. Izykowski,et al.  Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements , 2006, IEEE Transactions on Power Delivery.

[12]  M. Bockarjova,et al.  Enhancing Fault Location Performance on Power Transmission Lines , 2007, 2007 IEEE Lausanne Power Tech.

[13]  Eugeniusz Rosolowski,et al.  A two-end method of fault location immune to saturation of current transformers , 2004 .

[14]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[15]  H. P. Williams,et al.  Model Building in Mathematical Programming , 1979 .

[16]  A. T. Johns,et al.  New technique for the accurate location of earth faults on transmission systems , 1995 .

[17]  I. Zamora,et al.  Best ANN structures for fault location in single-and double-circuit transmission lines , 2005, IEEE Transactions on Power Delivery.

[18]  Mladen Kezunovic,et al.  Locating faults in the transmission network using sparse field measurements, simulation data and genetic algorithm , 2004 .

[19]  Gary W. Chang,et al.  Power System Analysis , 1994 .

[20]  James S. Thorp,et al.  Computer Relaying for Power Systems , 2009 .