Multibody system of the upper limb including a reverse shoulder prosthesis.

The reverse shoulder replacement, recommended for the treatment of several shoulder pathologies such as cuff tear arthropathy and fractures in elderly people, changes the biomechanics of the shoulder when compared to the normal anatomy. Although several musculoskeletal models of the upper limb have been presented to study the shoulder joint, only a few of them focus on the biomechanics of the reverse shoulder. This work presents a biomechanical model of the upper limb, including a reverse shoulder prosthesis, to evaluate the impact of the variation of the joint geometry and position on the biomechanical function of the shoulder. The biomechanical model of the reverse shoulder is based on a musculoskeletal model of the upper limb, which is modified to account for the properties of the DELTA® reverse prosthesis. Considering two biomechanical models, which simulate the anatomical and reverse shoulder joints, the changes in muscle lengths, muscle moment arms, and muscle and joint reaction forces are evaluated. The muscle force sharing problem is solved for motions of unloaded abduction in the coronal plane and unloaded anterior flexion in the sagittal plane, acquired using video-imaging, through the minimization of an objective function related to muscle metabolic energy consumption. After the replacement of the shoulder joint, significant changes in the length of the pectoralis major, latissimus dorsi, deltoid, teres major, teres minor, coracobrachialis, and biceps brachii muscles are observed for a reference position considered for the upper limb. The shortening of the teres major and teres minor is the most critical since they become unable to produce active force in this position. Substantial changes of muscle moment arms are also observed, which are consistent with the literature. As expected, there is a significant increase of the deltoid moment arms and more fibers are able to elevate the arm. The solutions to the muscle force sharing problem support the biomechanical advantages attributed to the reverse shoulder design and show an increase in activity from the deltoid, teres minor, and coracobrachialis muscles. The glenohumeral joint reaction forces estimated for the reverse shoulder are up to 15% lower than those in the normal shoulder anatomy. The data presented here complements previous publications, which, all together, allow researchers to build a biomechanical model of the upper limb including a reverse shoulder prosthesis.

[1]  F. V. D. van der Helm,et al.  Geometry parameters for musculoskeletal modelling of the shoulder system. , 1992, Journal of biomechanics.

[2]  V. Spitzer,et al.  The visible human male: a technical report. , 1996, Journal of the American Medical Informatics Association : JAMIA.

[3]  K. An,et al.  Parameters for modeling the upper extremity. , 1997, Journal of biomechanics.

[4]  F.C.T. van der Helm The ‘reversed’ glenohumeral endoprosthesis: The role of the rotator cuff muscles for stability and strength , 1998 .

[5]  L. G. Watson,et al.  Removing swing from a handstand on rings using a properly timed backward giant circle: a simulation solution. , 1997, Journal of biomechanics.

[6]  C. Spoor,et al.  Measuring muscle and joint geometry parameters of a shoulder for modeling purposes. , 1999, Journal of biomechanics.

[7]  M G Pandy,et al.  Musculoskeletal Model of the Upper Limb Based on the Visible Human Male Dataset , 2001, Computer methods in biomechanics and biomedical engineering.

[8]  J. Ambrósio,et al.  Kinematic Data Consistency in the Inverse Dynamic Analysis of Biomechanical Systems , 2002 .

[9]  F. Helm,et al.  Musculo-skeletal modelling of the shoulder , 2003 .

[10]  G Walch,et al.  Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. , 2004, The Journal of bone and joint surgery. British volume.

[11]  Philippe Favre,et al.  An algorithm for estimation of shoulder muscle forces for clinical use. , 2005, Clinical biomechanics.

[12]  M. Matava,et al.  Partial-Thickness Rotator Cuff Tears , 2005, The American journal of sports medicine.

[13]  Pascal Boileau,et al.  Grammont reverse prosthesis: design, rationale, and biomechanics. , 2005, Journal of shoulder and elbow surgery.

[14]  Matthew Vasey,et al.  The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. , 2005, The Journal of bone and joint surgery. American volume.

[15]  L. D. De Wilde,et al.  Functional Recovery after a Reverse Prosthesis for Reconstruction of the Proximal Humerus in Tumor Surgery , 2005, Clinical orthopaedics and related research.

[16]  C Gerber,et al.  Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. , 2005, The Journal of bone and joint surgery. American volume.

[17]  F. V. D. van der Helm,et al.  The relationship between two different mechanical cost functions and muscle oxygen consumption. , 2006, Journal of biomechanics.

[18]  Matthew Vasey,et al.  The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. a minimum two-year follow-up study of sixty patients surgical technique. , 2006, The Journal of bone and joint surgery. American volume.

[19]  G R Johnson,et al.  A model for the prediction of the forces at the glenohumeral joint , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  Kamal I. Bohsali,et al.  Complications of total shoulder arthroplasty. , 2006, The Journal of bone and joint surgery. American volume.

[21]  S. B. Mostofi,et al.  Biomechanical considerations of the normal and rotator cuff deficient shoulders and the reverse shoulder prosthesis , 2007 .

[22]  Don B Chaffin,et al.  A mathematical musculoskeletal shoulder model for proactive ergonomic analysis , 2007, Computer methods in biomechanics and biomedical engineering.

[23]  D. Katz,et al.  A history of the reverse shoulder prosthesis , 2007 .

[24]  A Terrier,et al.  Simulated joint and muscle forces in reversed and anatomic shoulder prostheses. , 2008, The Journal of bone and joint surgery. British volume.

[25]  W. Willems,et al.  Contribution of the Reverse Endoprosthesis to Glenohumeral Kinematics , 2008, Clinical orthopaedics and related research.

[26]  Andreas Kontaxis,et al.  Adaptation of scapula lateral rotation after reverse anatomy shoulder replacement , 2008, Computer methods in biomechanics and biomedical engineering.

[27]  T. Wright,et al.  An evaluation of the relationships between reverse shoulder design parameters and range of motion, impingement, and stability. , 2009, Journal of shoulder and elbow surgery.

[28]  Matt Morgan,et al.  Reverse total shoulder arthroplasty , 2015, Radiopaedia.org.

[29]  G R Johnson,et al.  The biomechanics of reverse anatomy shoulder replacement--a modelling study. , 2009, Clinical biomechanics.

[30]  Milad Masjedi,et al.  Glenohumeral contact forces in reversed anatomy shoulder replacement. , 2010, Journal of biomechanics.

[31]  Laurence Cheze,et al.  A new method for motion capture of the scapula using an optoelectronic tracking device: a feasibility study , 2010, Computer methods in biomechanics and biomedical engineering.

[32]  M. Pandy,et al.  Moment arms of the shoulder musculature after reverse total shoulder arthroplasty. , 2010, The Journal of bone and joint surgery. American volume.

[33]  J. Sánchez-Sotelo Total Shoulder Arthroplasty , 2011, The open orthopaedics journal.

[34]  Marcus G Pandy,et al.  Muscle and joint‐contact loading at the glenohumeral joint after reverse total shoulder arthroplasty , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[35]  S. Sherman,et al.  Scapular Notching: Recognition and Strategies to Minimize Clinical Impact , 2011, Clinical orthopaedics and related research.

[36]  Frans C. T. van der Helm,et al.  Development of a comprehensive musculoskeletal model of the shoulder and elbow , 2011, Medical & Biological Engineering & Computing.

[37]  R. M. Greiwe,et al.  Reverse Total Shoulder Arthroplasty—Biomechanics and Rationale , 2011 .

[38]  D. R. Stephenson,et al.  Effect of humeral component version on impingement in reverse total shoulder arthroplasty. , 2011, Journal of shoulder and elbow surgery.

[39]  Jorge Ambrósio,et al.  Multibody biomechanical models of the upper limb , 2011 .

[40]  G. Walch,et al.  The teres minor muscle in rotator cuff tendon tears , 2011, Skeletal Radiology.

[41]  Jangwhon Yoon,et al.  Kinematic analysis of dynamic shoulder motion in patients with reverse total shoulder arthroplasty. , 2012, Journal of shoulder and elbow surgery.

[42]  Jorge Ambrósio,et al.  A multibody biomechanical model of the upper limb including the shoulder girdle , 2012 .

[43]  Luca Modenese,et al.  Prediction of hip contact forces and muscle activations during walking at different speeds , 2012 .

[44]  Rainer Bader,et al.  HiL simulation for testing joint stability after total knee arthroplasty , 2012 .

[45]  C. Perka,et al.  Lateralized Reverse Shoulder Arthroplasty Maintains Rotational Function of the Remaining Rotator Cuff , 2013, Clinical orthopaedics and related research.

[46]  W. Blajer,et al.  Modeling and computational issues in the inverse dynamics simulation of triple jump , 2014 .