Ideal Characteristics of a Laser-Protected Endotracheal Tube: ABEA and AHNS Member Survey and Biomechanical Testing

Objectives: To determine the characteristics of laser-protected endotracheal tubes (LPETs) valued by otolaryngologists performing transoral laser surgery in the head and neck and to measure LPET stiffness. Methods: An online questionnaire was completed by American Broncho-Esophagological Association (ABEA) and American Head and Neck Society (AHNS) members. LPET distal end compliance was measured in a biomechanics laboratory. Results: A total of 228 out of 2109 combined ABEA and AHNS members completed the survey. The following LPET characteristics, which were properties of the Medtronic Laser-Shield II tube (MLST), were highly valued: softness and flexibility, surface smoothness, and a tight-to-shaft balloon (all P < .01). Prior to industry-driven discontinuation of the MLST, 52% of surgeons (78% of fellowship-trained laryngologists [FTLs]) reported using it; afterward, 58% reported using the stainless steel, Mallinckrodt Laser-Flex tube (MLFT). Forty-six percent of all respondents (69% of FTLs) did not consider cost being a factor in LPET choice. Biomechanical testing revealed the distal end of the MLST to be 3.45 times more compliant than the MLFT (P < .01). Conclusion: Members of the ABEA and AHNS, particularly FTLs, highly value distinguishing properties of the now discontinued MLST. Manufacturers should consider this in the design of new LPETs.

[1]  Lee P. Smith,et al.  Surgical Fires in Laser Laryngeal Surgery , 2015, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[2]  Carolyn A. Coughlan,et al.  Evaluating the Effects of a 532-nm Fiber-Based KTP Laser on Transoral Laser Surgery Supplies , 2013, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[3]  F. Dillon,et al.  A Comparison of CO2 Laser Ignition of the Xomed, Plastic, and Rubber Endotracheal Tubes , 1993, Anesthesia and analgesia.

[4]  R. Gonzalez,et al.  The resistance to carbon dioxide laser ignition of a new endotracheal tube: Xomed Laser-Shield II. , 1992, Journal of clinical anesthesia.

[5]  M. Strong,et al.  Laser Surgery in the Larynx Early Clinical Experience with Continuous Co2 Laser , 1972, The Annals of otology, rhinology, and laryngology.

[6]  Marvin P. Fried,et al.  Laser resistant stainless steel endotracheal tube: Experimental and clinical evaluation , 1991, Lasers in surgery and medicine.