Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

[1]  S. Bossuyt,et al.  Damage Detection in CFRP Components Using DIC , 2016 .

[2]  Rune Brincker,et al.  Vibration Based Inspection of Civil Engineering Structures , 1993 .

[3]  Christer Ullberg,et al.  Measurements of a dual-energy fast photon counting CdTe detector with integrated charge sharing correction , 2013, Medical Imaging.

[4]  U. Meier,et al.  Carbon Fiber Reinforced Polymer Cables: Why? Why Not? What If? , 2012 .

[5]  Phil E. Irving,et al.  Fatigue damage characterization in carbon fibre composite materials using an electrical potential technique , 1998 .

[6]  V. Sukhorukov,et al.  Non-destructive testing of steel wire ropes in Russia , 1998 .

[7]  G. Rebel,et al.  Lightweight ropes for lifting applications , 2006 .

[8]  Brahim Benmokrane,et al.  Durability Performance and Service Life of CFCC Tendons Exposed to Elevated Temperature and Alkaline Environment , 2016 .

[9]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[10]  J. Jakubek,et al.  Radiogram enhancement and linearization using the beam hardening correction method , 2009 .

[11]  M. Kanerva,et al.  The Effects of Debonding on the Low-Velocity Impact Response of Steel-CFRP Fibre Metal Laminates , 2016, Applied Composite Materials.

[12]  Annett Schmieder,et al.  Failure Analysis of High-Strength Fiber Ropes , 2015 .

[13]  Uwe Ewert,et al.  Photon counting and energy discriminating x-ray detectors - benefits and applications , 2016 .

[14]  D Vavrik,et al.  X-ray inspection of composite materials for aircraft structures using detectors of Medipix type , 2014 .