Dynamic correction for parallel conductance, GP, and gain factor, alpha, in invasive murine left ventricular volume measurements.

The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine G(P) and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 +/- 15.33 microl error) compared with those same parameters calculated by SV calibrated conductance (35.89 +/- 73.22 microl error) and by cuvette calibrated conductance (-7.53 +/- 16.23 microl ES and -29.10 +/- 31.53 microl ED error). To utilize the admittance approach, myocardial permittivity (epsilon(m)) and conductivity (sigma(m)) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 +/- 2,700 control, 21,267 +/- 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 +/- 13.06 microl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 +/- 1.4 to 12.5 +/- 6.6 mmHg/microl Wei's equation (P < 0.05), 3.3 +/- 1.2 to 8.8 +/- 5.1 mmHg/microl using Baan's equation (P = not significant)]. New theory and method for instantaneous G(P) removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic G(P)) and Wei's equation (dynamic alpha) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.

[1]  J A Pearce,et al.  Development of a multifrequency conductance catheter-based system to determine LV function in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[2]  U. Flögel,et al.  Direct comparison of magnetic resonance imaging and conductance microcatheter in the evaluation of left ventricular function in mice , 2005, Basic Research in Cardiology.

[3]  G L Freeman,et al.  Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals. , 2000, American journal of physiology. Heart and circulatory physiology.

[4]  Pál Pacher,et al.  Measurement of cardiac function using pressure–volume conductance catheter technique in mice and rats , 2008, Nature Protocols.

[5]  Steffen Ringgaard,et al.  Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration. , 2007, American journal of physiology. Heart and circulatory physiology.

[6]  A. Wear CIRCULATION , 1964, The Lancet.

[7]  S. Kun,et al.  Analysis of conductance volumetric measurement error sources , 2006, Medical and Biological Engineering and Computing.

[8]  D. Kass,et al.  Compartmentalization of Cardiac &bgr;-Adrenergic Inotropy Modulation by Phosphodiesterase Type 5 , 2007 .

[9]  Ahmad Y. Sheikh,et al.  Magnetic resonance imaging of progressive cardiomyopathic changes in the db/db mouse. , 2007, American journal of physiology. Heart and circulatory physiology.

[10]  Jonathan W. Valvano,et al.  Volume Catheter Parallel Conductance Varies Between End-Systole and End-Diastole , 2007, IEEE Transactions on Biomedical Engineering.

[11]  Jonathan W. Valvano,et al.  Nonlinear conductance-volume relationship for murine conductance catheter measurement system , 2005, IEEE Transactions on Biomedical Engineering.

[12]  J. Karliner,et al.  Cardiac matrix metalloproteinase-2 expression independently induces marked ventricular remodeling and systolic dysfunction. , 2007, American journal of physiology. Heart and circulatory physiology.

[13]  上村 和紀 A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats , 2006 .

[14]  P. Steendijk,et al.  The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo , 1993, IEEE Transactions on Biomedical Engineering.

[15]  B Buis,et al.  Continuous measurement of left ventricular volume in animals and humans by conductance catheter. , 1984, Circulation.

[16]  E. Foster,et al.  Left ventricular pressure-volume relationship in conscious mice. , 2007, American journal of physiology. Heart and circulatory physiology.

[17]  B. Cravatt,et al.  Hemodynamic profile, responsiveness to anandamide, and baroreflex sensitivity of mice lacking fatty acid amide hydrolase. , 2005, American journal of physiology. Heart and circulatory physiology.

[18]  N. Stergiopulos,et al.  Nonlinear isochrones in murine left ventricular pressure-volume loops: how well does the time-varying elastance concept hold? , 2006, American journal of physiology. Heart and circulatory physiology.

[19]  A. Shoukas,et al.  Simulated Microgravity Produces Attenuated Baroreflex-Mediated Pressor , Chronotropic , and Inotropic Responses in Mice , 2005 .

[20]  D. Kass,et al.  Estimation of parallel conductance by dual-frequency conductance catheter in mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[21]  C. H. Chen,et al.  Special Communication , 2004 .

[22]  D. Kass,et al.  Minimal force‐frequency modulation of inotropy and relaxation of in situ murine heart , 2001, The Journal of physiology.

[23]  Jonathan W. Valvano,et al.  Electrical Conductivity and Permittivity of Murine Myocardium , 2009, IEEE Transactions on Biomedical Engineering.

[24]  T J Gawne,et al.  Estimating left ventricular offset volume using dual-frequency conductance catheters. , 1987, Journal of applied physiology.

[25]  Andrew D McCulloch,et al.  Role of diastolic properties in the transition to failure in a mouse model of the cardiac dilatation. , 2006, American journal of physiology. Heart and circulatory physiology.

[26]  E. T. van der Velde,et al.  Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. , 1981, Cardiovascular research.

[27]  A A Shoukas,et al.  Does volume catheter parallel conductance vary during a cardiac cycle? , 1990, The American journal of physiology.

[28]  M. Zile,et al.  Accelerated LV remodeling after myocardial infarction in TIMP-1-deficient mice: effects of exogenous MMP inhibition. , 2005, American journal of physiology. Heart and circulatory physiology.

[29]  Sharon Thomsen,et al.  Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart. , 2006, American journal of physiology. Heart and circulatory physiology.

[30]  A. Redington,et al.  Right ventricular volume measurement: can conductance do it better? , 2000, Physiological measurement.