Towards the patient-specific design of flow diverters made from helix-like wires: an optimization study
暂无分享,去创建一个
Bastien Chopard | Makoto Ohta | Hitomi Anzai | B. Chopard | M. Ohta | Mingzi Zhang | Mingzi Zhang | H. Anzai
[1] Shigeru Obayashi,et al. Two-Dimensional Optimization of a Stent for an Aneurysm , 2010 .
[2] Chander Sadasivan,et al. Endoluminal scaffolds for vascular reconstruction and exclusion of aneurysms from the cerebral circulation. , 2010, Stroke.
[3] Cecilia R. Aragon,et al. Optimization by Simulated Annealing: An Experimental Evaluation; Part I, Graph Partitioning , 1989, Oper. Res..
[4] Rainald Löhner,et al. Simulation of intracranial aneurysm stenting: Techniques and challenges , 2009 .
[5] Yi Qian,et al. Three-dimensional hemodynamic design optimization of stents for cerebral aneurysms , 2014, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[6] I ScottKirkpatrick. Optimization by Simulated Annealing: Quantitative Studies , 1984 .
[7] H. Harasaki,et al. Effects of stent design and serum cholesterol level on the restenosis rate in atherosclerotic rabbits. , 1993, American heart journal.
[8] David F Kallmes,et al. Flow Diversion for Intracranial Aneurysms: A Review , 2011, Stroke.
[9] D. Kallmes,et al. Hemodynamic analysis of fast and slow aneurysm occlusions by flow diversion in rabbits , 2014, Journal of NeuroInterventional Surgery.
[10] Scott Kirkpatrick,et al. Optimization by simulated annealing: Quantitative studies , 1984 .
[11] Rafik Ouared,et al. A LATTICE BOLTZMANN MODELING OF BLOODFLOW IN CEREBRAL ANEURYSMS , 2010 .
[12] A. Ajdari,et al. In vitro and computational thrombosis on artificial surfaces with shear stress. , 2010, Artificial organs.
[13] J. Gomori,et al. Delayed complications after flow-diverter stenting: Reactive in-stent stenosis and creeping stents , 2014, Journal of Clinical Neuroscience.
[14] C. Putman,et al. Hemodynamics of Cerebral Aneurysms. , 2009, Annual review of fluid mechanics.
[15] J. Boon. The Lattice Boltzmann Equation for Fluid Dynamics and Beyond , 2003 .
[16] Philipp Berg,et al. An automatic CFD-based flow diverter optimization principle for patient-specific intracranial aneurysms. , 2015, Journal of biomechanics.
[17] A. Wakhloo,et al. Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity , 1997, Annals of Biomedical Engineering.
[18] Cecilia R. Aragon,et al. Optimization by Simulated Annealing: An Experimental Evaluation; Part II, Graph Coloring and Number Partitioning , 1991, Oper. Res..
[19] J. Gabrillargues,et al. Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study , 2012, American Journal of Neuroradiology.
[20] Stephen Rudin,et al. The Asymmetric Vascular Stent: Efficacy in a Rabbit Aneurysm Model , 2009, Stroke.
[21] Gilead Moiseyev,et al. Computational modeling of thrombosis as a tool in the design and optimization of vascular implants. , 2013, Journal of biomechanics.
[22] D R Hose,et al. Application and validation of the lattice Boltzmann method for modelling flow-related clotting. , 2007, Journal of biomechanics.
[23] Alejandro F Frangi,et al. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007. , 2008, Journal of biomechanics.
[24] Joon Sang Lee,et al. The Effect of Stent Porosity and Strut Shape on Saccular Aneurysm and its Numerical Analysis with Lattice Boltzmann Method , 2010, Annals of Biomedical Engineering.
[25] Daniel R. Bednarek,et al. Measurement of flow modification in phantom aneurysm model: comparison of coils and a longitudinally and axially asymmetric stent--initial findings. , 2004, Radiology.
[26] Abdul I. Barakat,et al. Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents , 2005, Annals of Biomedical Engineering.
[27] Kyehan Rhee,et al. Changes of Flow Characteristics by Stenting in Aneurysm Models: Influence of Aneurysm Geometry and Stent Porosity , 2002, Annals of Biomedical Engineering.
[28] Bongjae Chung,et al. CFD for Evaluation and Treatment Planning of Aneurysms: Review of Proposed Clinical Uses and Their Challenges , 2014, Annals of Biomedical Engineering.
[29] Toshiyuki Hayase,et al. Optimization of strut placement in flow diverter stents for four different aneurysm configurations. , 2014, Journal of biomechanical engineering.
[30] J. Pruvo,et al. Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms , 2010, Stroke.
[31] Bastien Chopard,et al. Optimization of flow diverters for cerebral aneurysms , 2012, J. Comput. Sci..
[32] T. Ishikawa,et al. Inflow into Saccular Cerebral Aneurysms at Arterial Bends , 2008, Annals of Biomedical Engineering.