Hybrid Ultrasound/Magnetic Resonance Simultaneous Acquisition and Image Fusion for Motion Monitoring in the Upper Abdomen

ObjectivesThe combination of ultrasound (US) and magnetic resonance imaging (MRI) may provide a complementary description of the investigated anatomy, together with improved guidance and assessment of image-guided therapies. The aim of the present study was to integrate a clinical setup for simultaneous US and magnetic resonance (MR) acquisition to obtain synchronized monitoring of liver motion. The feasibility of this hybrid imaging and the precision of image fusion were evaluated. Materials and MethodsUltrasound imaging was achieved using a clinical US scanner modified to be MR compatible, whereas MRI was achieved on 1.5- and 3-T clinical scanners. Multimodal registration was performed between a high-resolution T1 3-dimensional (3D) gradient echo (volume interpolated gradient echo) during breath-hold and a simultaneously acquired 2D US image, or equivalent, retrospective registration of US imaging probe in the coordinate frame of MRI. A preliminary phantom study was followed by 4 healthy volunteer acquisitions, performing simultaneous 4D MRI and 2D US harmonic imaging (Fo = 2.2 MHz) under free breathing. ResultsNo characterized radiofrequency mutual interferences were detected under the tested conditions with commonly used MR sequences in clinical routine, during simultaneous US/MRI acquisition. Accurate spatial matching between the 2D US and the corresponding MRI plane was obtained during breath-hold. In situ fused images were delivered. Our 4D MRI sequence permitted the dynamic reconstruction of the intra-abdominal motion and the calculation of high temporal resolution motion field vectors. ConclusionsThis study demonstrates that, truly, simultaneous US/MR dynamic acquisition in the abdomen is achievable using clinical instruments. A potential application is the US/MR hybrid guidance of high-intensity focused US therapy in the liver.

[1]  C. Kuhl,et al.  Different Intravenous Contrast Media Concentrations Do Not Affect Clinical Assessment of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Scans in an Intraindividual Comparison , 2012, Investigative radiology.

[2]  Katherine W Ferrara,et al.  Insonation of Targeted Microbubbles Produces Regions of Reduced Blood Flow Within Tumor Vasculature , 2012, Investigative radiology.

[3]  Lorena Petrusca,et al.  Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo , 2012, Physics in medicine and biology.

[4]  K. Hynynen,et al.  In Vitro and In Vivo High-Intensity Focused Ultrasound Thrombolysis , 2012, Investigative radiology.

[5]  Patrick Gross,et al.  Reference-Free PRFS MR-Thermometry Using Near-Harmonic 2-D Reconstruction of the Background Phase , 2012, IEEE Transactions on Medical Imaging.

[6]  Jeroen J. Bax,et al.  Tissue-Velocity Magnetic Resonance Imaging and Tissue Doppler Imaging to Assess Regional Myocardial Diastolic Velocities at the Right Ventricle in Corrected Pediatric Tetralogy of Fallot Patients , 2011, Investigative Radiology.

[7]  Jae-Hun Kim,et al.  Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Immediate Therapeutic Response of Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Symptomatic Uterine Fibroids , 2011, Investigative radiology.

[8]  Gábor Székely,et al.  Keep Breathing! Common Motion Helps Multi-modal Mapping , 2011, MICCAI.

[9]  J. Chapelon,et al.  Prostate cancer ablation with transrectal high-intensity focused ultrasound: assessment of tissue destruction with contrast-enhanced US. , 2011, Radiology.

[10]  Rajiv Chopra,et al.  Development of a platform for co-registered ultrasound and MR contrast imaging in vivo , 2011, Physics in medicine and biology.

[11]  S. Dindyal,et al.  Ultrasound microbubble contrast and current clinical applications. , 2011, Recent patents on cardiovascular drug discovery.

[12]  D. Louis Collins,et al.  Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery , 2011, International Journal of Computer Assisted Radiology and Surgery.

[13]  Carlos D. Correa,et al.  In Vivo Mapping of Vascular Inflammation Using Multimodal Imaging , 2010, PloS one.

[14]  Luis Martí-Bonmatí,et al.  Multimodality imaging techniques. , 2010, Contrast media & molecular imaging.

[15]  Matthias Hofmann,et al.  Diffusion Tensor Imaging in a Human PET/MR Hybrid System , 2010, Investigative radiology.

[16]  Rares Salomir,et al.  Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging. , 2010, Medical physics.

[17]  K. Hynynen MRI-guided focused ultrasound treatments. , 2010, Ultrasonics.

[18]  Maxim Zaitsev,et al.  Hybrid ultrasound MRI for improved cardiac imaging and real‐time respiration control , 2010, Magnetic resonance in medicine.

[19]  M. Hashizume,et al.  An effective point-based registration tool for surgical navigation , 2010, Surgical Endoscopy.

[20]  John C. Bischof,et al.  Monitoring and guidance of minimally-invasive thermal therapy using diagnostic ultrasound , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Eigil Samset,et al.  Evaluation of bivariate correlation ratio similarity metric for rigid registration of US/MR images of the liver , 2009, International Journal of Computer Assisted Radiology and Surgery.

[22]  F. Jolesz MRI-guided focused ultrasound surgery. , 2007, Annual review of medicine.

[23]  David W Townsend,et al.  Positron emission tomography/computed tomography. , 2008, Seminars in nuclear medicine.

[24]  J. Knuuti,et al.  Positron emission tomography and molecular imaging , 2008, Heart.

[25]  Edmund Y. Lam,et al.  Simultaneous Ultrasound and MRI System for Breast Biopsy: Compatibility Assessment and Demonstration in a Dual Modality Phantom , 2008, IEEE Transactions on Medical Imaging.

[26]  Rajiv Chopra,et al.  Progress in Multimodality Imaging: Truly Simultaneous Ultrasound and Magnetic Resonance Imaging , 2007, IEEE Transactions on Medical Imaging.

[27]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[28]  Jing Ren,et al.  Dynamic 3D Ultrasound and MR Image Registration of the Beating Heart , 2005, MICCAI.

[29]  S. Koscielny,et al.  Role of contrast-enhanced color Doppler ultrasonography and dynamic flow in the evaluation of hepatic tumors treated with radiofrequency , 2005, Cancer imaging : the official publication of the International Cancer Imaging Society.

[30]  Peter Hunold,et al.  Parallel acquisition techniques for accelerated volumetric interpolated breath‐hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity , 2005, Journal of magnetic resonance imaging : JMRI.

[31]  P. Phillips,et al.  Contrast–agent detection and quantification , 2004, European radiology.

[32]  Mathieu Pernot,et al.  3-D real-time motion correction in high-intensity focused ultrasound therapy. , 2004, Ultrasound in medicine & biology.

[33]  Accuracy of MR temperature measurement based on chemical shift change for radiofrequency ablation using hook-shaped electrodes. , 2004, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[34]  Matthias Günther,et al.  Ultrasound‐guided MRI: Preliminary results using a motion phantom , 2004, Magnetic resonance in medicine.

[35]  A. DeMaria,et al.  Microbubble contrast agents for echocardiography: rationale, composition, ultrasound interactions, and safety. , 2004, Cardiology clinics.

[36]  David J. Hawkes,et al.  Registration of freehand 3D ultrasound and magnetic resonance liver images , 2004, Medical Image Anal..

[37]  Paul K Marsden,et al.  Simultaneous PET and NMR. , 2002, The British journal of radiology.

[38]  T. Azuma,et al.  MRI-compatible ultrasonic probe for minimally invasive therapy , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[39]  D. Collins,et al.  Automatic non-linear MRI-ultrasound registration for the correction of intra-operative brain deformations , 2001, MICCAI.

[40]  D. Rubens,et al.  Three-dimensional registration and fusion of ultrasound and MRI using major vessels as fiducial markers , 2001, IEEE Transactions on Medical Imaging.

[41]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[42]  N. Rofsky,et al.  Abdominal MR imaging with a volumetric interpolated breath-hold examination. , 1999, Radiology.

[43]  Mickael Tanter,et al.  Self-defocusing in ultrasonic hyperthermia: Experiment and simulation , 1999 .

[44]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[45]  T. Bowen,et al.  In vivo temperature dependence of ultrasound speed in tissue and its application to noninvasive temperature monitoring. , 1979, Ultrasonic imaging.