Ventilation rates in the bedrooms of 500 Danish children

Abstract The ongoing “Indoor Environment and Children’s Health” (IECH) study investigates the environmental risk factors in homes and their association with asthma and allergy among children aged 1–5 years. As part of the study, the homes of 500 children between 3 and 5 years of age were inspected. The selected children included 200 symptomatic children (cases) and 300 randomly selected children (bases). As part of the inspection, the concentration of carbon dioxide in the bedrooms of the children was continuously measured over an average of 2.5 days. The ventilation rates in the rooms during the nights when the children were sleeping in the room were calculated using a single-zone mass balance for the occupant-generated CO 2 . The calculated air change rates were log-normally distributed ( R 2  > 0.98). The geometric mean of the air change rates in both the case and the base group was 0.46 air changes per hour (h −1 ; geom. SD = 2.08 and 2.13, respectively). Approximately 57% of both cases and bases slept at a lower ventilation rate than the minimum required ventilation rate of 0.5 h −1 in new Danish dwellings. Only 32% of the bedrooms had an average CO 2 concentration below 1000 ppm during the measured nights. Twenty-three percent of the rooms experienced at least a 20-minute period during the night when the CO 2 concentration was above 2000 ppm and 6% of the rooms experienced concentrations above 3000 ppm. The average air change rate was higher with more people sleeping in the room. The air change rate did not change with the increasing outdoor temperature over the 10-week experimental period. The calculation method provides an estimate of the total airflow into the bedroom, including airflows both from outdoors and from adjacent spaces. To study the accuracy of the calculated air change rates and their deviation from the true outside air change rates, we calculated CO 2 concentrations at different given air change rates using an indoor air quality and ventilation model (Contam). Subsequently we applied our calculation procedure to the obtained data. The air change rate calculated from the generated CO 2 concentrations was found to be between 0% and 51% lower than the total air change rate defined in the input variables for the model. It was, however, higher than the true outside air change rate. The relative error depended on the position of the room in relation to the adjacent rooms, occupancy in the adjacent room, the nominal air change rate and room-to-room airflows.

[1]  W. Ott,et al.  The Effect of Opening Windows on Air Change Rates in Two Homes , 2002, Journal of the Air & Waste Management Association.

[2]  D G Shendell,et al.  Residential air exchange rates in three major US metropolitan areas: results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999-2001. , 2010, Indoor air.

[3]  David E. Burmaster,et al.  Residential Air Exchange Rates in the United States: Empirical and Estimated Parametric Distributions by Season and Climatic Region , 1995 .

[4]  Emenius,et al.  Mechanical ventilation protects one‐storey single‐dwelling houses against increased air humidity, domestic mite allergens and indoor pollutants in a cold climatic region , 1998, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[5]  G. Iwashita,et al.  The effects of human behavior on natural ventilation rate and indoor air environment in summer − a field study in southern Japan , 1997 .

[6]  M. Wickman,et al.  Ventilation in homes infested by house‐dust mites , 1995, Allergy.

[7]  Max H. Sherman Air change rate and airtightness in buildings , 1990 .

[8]  Andrew K. Persily,et al.  What we Think we Know about Ventilation , 2006 .

[9]  Carine Dubrul,et al.  Inhabitant behaviour with respect to ventilation - a summary report of IEA annex VIII , 1988 .

[10]  A. Melikov,et al.  Distribution of carbon dioxide produced by people in a room:: Part 1 - Laboratory study , 2004 .

[11]  J Sundell,et al.  Association between ventilation rates in 390 Swedish homes and allergic symptoms in children. , 2005, Indoor air.

[12]  O Seppänen,et al.  Ventilation and health in non-industrial indoor environments: report from a European multidisciplinary scientific consensus meeting (EUROVEN). , 2002, Indoor air.

[13]  Leif Øie,et al.  Is diabetes mellitus associated with prostate cancer incidence and survival , 1999 .

[14]  N. C. Bergsøe,et al.  Radon and Natural Ventilation in Newer Danish Single‐Family Houses , 1997 .

[15]  M Svartengren,et al.  Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE). , 2004, Indoor air.

[16]  R. Dahl,et al.  Clinical efficacy of reduction in house‐dust mite exposure in specially designed, mechanically ventilated “healthy” homes , 1994, Allergy.

[17]  Hr Trechsel Building Air Change Rate and Infiltration Measurements , 1980 .

[18]  F. R. Stephen,et al.  Mechanical ventilation and high-efficiency vacuum cleaning: A combined strategy of mite and mite allergen reduction in the control of mite-sensitive asthma. , 2000, The Journal of allergy and clinical immunology.

[19]  W. Fisk,et al.  Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings. , 1999, Indoor air.

[20]  Hans Stymne,et al.  Measuring ventilation rates in the Swedish housing stock , 1994 .

[21]  L. Wallace,et al.  Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows* , 2002, Journal of Exposure Analysis and Environmental Epidemiology.

[22]  Hr Trechsel,et al.  Measured Air Leakage of Buildings , 1986 .

[23]  Jan Sundell,et al.  On the Association Between Building Ventilation Characteristics, some Indoor Environmental Exposures, some Allergic Manifestations and Subjective Symptom Reports , 1994 .

[24]  B Kvisgaard,et al.  The User's Influence on Air Change , 1990 .

[25]  J. Penman,et al.  An experimental determination of ventilation rate in occupied rooms using atmospheric carbon dioxide concentration , 1980 .

[26]  Leif Øie,et al.  The Ventilation Rate of 344 Oslo Residences , 1998 .

[27]  J. Penman,et al.  Experimental determination of air-flow in a naturally ventilated room using metabolic carbon dioxide , 1982 .

[28]  William W. Nazaroff,et al.  Semivolatile organic compounds in indoor environments , 2008 .

[29]  Max H. Sherman,et al.  Analysis of errors associated with passive ventilation measurement techniques , 1989 .