Optical performance evaluation of a solar furnace by measuring the highly concentrated solar flux

We evaluated optical performance of a solar furnace in the KIER (Korea Institute of Energy Research) by measuring the highly concentrated solar flux with the flux mapping method. We presented and analyzed optical performance in terms of concentrated solar flux distribution and power distribution. We investigated concentration ratio, stagnation temperature, total power, and concentration accuracy with help of a modeling code based on the ray tracing method and thereby compared with other solar furnaces. We also discussed flux changes by shutter opening angles and by position adjustment of reflector facets. In the course of flux analysis, we provided a better understanding of reference flux measurement for calibration, reflectivity measurement with a portable reflectometer, shadowing area consideration for effective irradiation, as well as accuracy and repeatability of flux measurements. The results in the present study will help proper utilization of a solar furnace by facilitating comparison between flux measurements at different conditions and flux estimation during operation.

[1]  Eckhard Lüpfert,et al.  Beam Characterization and Improvement with a Flux Mapping System for Dish Concentrators , 2002 .

[2]  C. Dey,et al.  Sunshape distributions for terrestrial solar simulations , 2003 .

[3]  Aldo Steinfeld,et al.  A new high-flux solar furnace for high-temperature thermochemical research , 1999 .

[4]  Eckhard Lüpfert,et al.  Calibration corrections of solar tower flux density measurements , 2004 .

[5]  R. Monterreal,et al.  Hybrid heat flux measurement system for solar central receiver evaluation , 2004 .

[6]  Robert Gardon,et al.  An Instrument for the Direct Measurement of Intense Thermal Radiation , 1953 .

[7]  G. Johnston Focal region measurements of the 20 m2 tiled dish at the Australian National University , 1998 .

[8]  U. Groer,et al.  Experimenting with concentrated sunlight using the DLR solar furnace , 1996 .

[9]  L. W. Langley,et al.  Systematic error in the measurement of very high solar irradiance , 2003 .

[10]  A. Neumann,et al.  The influence of sunshape on the DLR Solar Furnace beam , 1999 .

[11]  Scott A. Jones,et al.  REPRESENTATIVE TERRESTRIAL SOLAR BRIGHTNESS PROFILES , 2002 .

[12]  F. Trombe,et al.  Thousand kW solar furnace, built by the National Center of Scientific Research, in Odeillo (France) , 1973 .

[13]  H. Tan,et al.  Numerical Study of Radiation Characteristics in a Dish Solar Collector System , 2008 .

[14]  Roland Winston,et al.  Performance characterization of the SERI High-Flux solar furnace , 1991 .

[15]  A. Neumann,et al.  Comparative Measurements of Different Solar Flux Gauge Types , 2001 .

[16]  N. Bjorndalen High Temperature Solar Furnace: Current Applications and Future Potential , 2003 .

[17]  Heat-Flux Analysis of Solar Furnace Using the Monte Carlo Ray-Tracing Method , 2011 .