Robustness of integrated backscatter for myocardial tissue characterization.

Integrated backscatter (IB) has been used for ultrasonic tissue characterization. To assess the potential variables in IB measurements, we performed both theoretical simulations and in vitro phantom measurements. First, we simulated data in which the scatterer position randomly was varied. IB values for the resulting images were calculated. Second, RF data from a tissue-mimicking phantom were acquired. Third, an adapted imaging approach, based on phase insensitivity, was evaluated. For both the simulations and phantom measurements, IB showed a standard deviation of +/-20%. These large deviations can be explained by variations in interference of signals and are not related to the state of the tissue. Small deviations in position of the scatterers resulted in important variations in IB. They must be taken into account and may limit the use of IB in cardiological applications. An improvement potentially can be obtained using phase insensitivity in new ultrasound processing schemes.

[1]  P. Suetens,et al.  Simulation of rf-data for use in ultrasonic tissue characterization , 1997 .

[2]  J.G. Miller,et al.  The effect of frequency on the magnitude of cyclic variation of backscatter in dogs and implications for prompt detection of acute myocardial ischemia , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  J. G. Miller,et al.  Effects of myocardial contraction on ultrasonic backscatter before and after ischemia. , 1984, The American journal of physiology.

[4]  J. G. Miller,et al.  Effects of Myocardial Ischemia on Quantitative Ultrasonic Backscatter and Identification of Responsible Determinants , 1981, Circulation research.

[5]  G. Tupholme Generation of acoustic pulses by baffled plane pistons , 1969 .

[6]  Melvin L. Marcus,et al.  Cardiac Imaging: A Companion to Braunwald's Heart Disease , 1991 .

[7]  F. Dunn,et al.  Ultrasonic Scattering in Biological Tissues , 1992 .

[8]  N Bom,et al.  Ultrasound myocardial integrated backscatter signal processing: frequency domain versus time domain. , 1993, Ultrasound in medicine & biology.

[9]  J. G. Miller,et al.  Changes in myocardial backscatter throughout the cardiac cycle. , 1983, Ultrasonic imaging.

[10]  Paul Suetens,et al.  The calculation of the transient near and far field of a baffled piston using low sampling frequencies , 1997 .

[11]  J. Strohbehn,et al.  Two-Dimensional Ultrasonic Variation in Myocardium Throughout the Cardiac Cycle , 1986 .

[12]  J. G. Miller,et al.  Sensitive detection of the effects of reperfusion on myocardium by ultrasonic tissue characterization with integrated backscatter. , 1986, Circulation.

[13]  F. Van de Werf,et al.  Software package for echocardiographic quantification: Leuven (SPEQLE) , 1996, Computers in Cardiology 1996.

[14]  J. G. Miller,et al.  Effects of Coronary Artery Occlusion and Reperfusion on Cardiac Cycle‐Dependent Variation of Myocardial Ultrasonic Backscatter , 1985, Circulation research.

[15]  N Bom,et al.  The relative contributions of myocardial wall thickness and ischemia to ultrasonic myocardial integrated backscatter during experimental ischemia. , 1991, Ultrasound in medicine & biology.

[16]  P Suetens,et al.  Acquisition and processing of the radio-frequency signal in echocardiography: a new global approach. , 1994, Ultrasound in medicine & biology.

[17]  L. J. Busse,et al.  Detection of spatially nonuniform ultrasonic radiation with phase sensitive (piezoelectric) and phase insensitive (acoustoelectric) receivers , 1981 .

[18]  L. J. Busse,et al.  Response characteristics of a finite aperture, phase insensitive ultrasonic receiver based upon the acoustoelectric effect , 1981 .

[19]  L S Wann,et al.  Intramyocardial variability in integrated backscatter: effects of coronary occlusion and reperfusion. , 1987, Circulation.

[20]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[21]  R. F. Wagner,et al.  Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[22]  W. McDicken,et al.  A comparison of methods used to calculate ultrasonic myocardial backscatter in the time domain. , 1994, Ultrasound in medicine & biology.

[23]  J. G. Miller,et al.  Ultrasonic characterization of myocardium. , 1985, Progress in cardiovascular diseases.

[24]  J G Miller,et al.  Assessment of myocardial viability by ultrasonic tissue characterization. , 1995, Coronary artery disease.

[25]  R. Krams,et al.  Influence of data processing on cyclic variation of integrated backscatter and wall thickness in stunned porcine myocardium , 1997 .

[26]  J E Heiserman,et al.  Ultrasonic tissue characterization: detection of acute myocardial ischemia in dogs. , 1985, Circulation.

[27]  E. Feleppa,et al.  Statistics of ultrasonic spectral parameters for prostate and liver examinations , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.