Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis.

Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by +/- 5 percent and +/- 10 percent, respectively. The results demonstrated that under axial tibial compressive loading (up to 1,400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young's modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson,s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1,400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson's ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson's ratio.

[1]  V C Mow,et al.  A transversely isotropic biphasic finite element model of the meniscus. , 1992, Journal of biomechanics.

[2]  R. J. Pawluk,et al.  Topography of the osteoarthritic thumb carpometacarpal joint and its variations with regard to gender, age, site, and osteoarthritic stage. , 1998, The Journal of hand surgery.

[3]  S L Woo,et al.  A validated three-dimensional computational model of a human knee joint. , 1999, Journal of biomechanical engineering.

[4]  G A Ateshian,et al.  Biomechanics of diarthrodial joints: a review of twenty years of progress. , 1993, Journal of biomechanical engineering.

[5]  A E Engin,et al.  Three-body segment dynamic model of the human knee. , 1993, Journal of biomechanical engineering.

[6]  C J Taylor,et al.  The use of active shape models for making thickness measurements of articular cartilage from MR images , 1997, Magnetic resonance in medicine.

[7]  V C Mow,et al.  Contact analysis of biphasic transversely isotropic cartilage layers and correlations with tissue failure. , 1999, Journal of biomechanics.

[8]  E. Abdel-Rahman,et al.  A two-dimensional dynamic anatomical model of the human knee joint. , 1993, Journal of biomechanical engineering.

[9]  R J Johnson,et al.  An analytical model of the knee. , 1976, Journal of biomechanics.

[10]  F Eckstein,et al.  Repeatability of patellar cartilage thickness patterns in the living, using a fat‐suppressed magnetic resonance imaging sequence with short acquisition time and three‐dimensinal data processing , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  E. Chao,et al.  A comparison of different methods in predicting static pressure distribution in articulating joints. , 1997, Journal of biomechanics.

[12]  C J Sutherland,et al.  Use of general purpose mechanical computer assisted engineering software in orthopaedic surgical planning: advantages and limitations. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[13]  T. Brown,et al.  The influence of basal cartilage calcification on dynamic juxtaarticular stress transmission. , 1993, Clinical orthopaedics and related research.

[14]  R Huiskes,et al.  Analytical stereophotogrammetric determination of three-dimensional knee-joint geometry. , 1985, Journal of biomechanics.

[15]  R. Woledge,et al.  The forces in the distal femur and the knee during walking and other activities measured by telemetry. , 1998, The Journal of arthroplasty.

[16]  D L Butler,et al.  Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments. , 1986, Journal of biomechanics.

[17]  D G Disler,et al.  Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images. , 1996, Radiology.

[18]  L. Blankevoort,et al.  Validation of a three-dimensional model of the knee. , 1996, Journal of biomechanics.

[19]  M. Pandy,et al.  A musculoskeletal model of the knee for evaluating ligament forces during isometric contractions. , 1997, Journal of biomechanics.

[20]  V. Mow,et al.  Biphasic indentation of articular cartilage--I. Theoretical analysis. , 1987, Journal of biomechanics.

[21]  M. Bendjaballah,et al.  Biomechanics of the human knee joint in compression: reconstruction, mesh generation and finite element analysis , 1995 .

[22]  V. Mow,et al.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments. , 1980, Journal of biomechanical engineering.

[23]  J. Mink,et al.  Occult cartilage and bone injuries of the knee: detection, classification, and assessment with MR imaging. , 1989, Radiology.

[24]  J O Galante,et al.  Model studies of the stiffness characteristics of the human knee joint. , 1983, Journal of biomechanics.

[25]  B Reider,et al.  Analysis of the Müller anterolateral femorotibial ligament reconstruction using a computerized knee model , 1986, The American journal of sports medicine.

[26]  D Resnick,et al.  Knee hyaline cartilage evaluated with MR imaging: a cadaveric study involving multiple imaging sequences and intraarticular injection of gadolinium and saline solution. , 1991, Radiology.

[27]  G. Glover,et al.  Short TE MR Microscopy: Accurate measurement and zonal differentiation of normal hyaline cartilage , 1997, Magnetic resonance in medicine.

[28]  F Eckstein,et al.  Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging. , 1997, Journal of biomechanics.

[29]  T. Andriacchi,et al.  Force displacement characteristics of the posterior cruciate ligament , 1992, The American journal of sports medicine.

[30]  T. Fukubayashi,et al.  The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints. , 1980, Acta orthopaedica Scandinavica.

[31]  J. Gregg,et al.  The impact of loading on deformation about posteromedial meniscal tears. , 2000, Orthopedics.

[32]  J R Essinger,et al.  A mathematical model for the evaluation of the behaviour during flexion of condylar-type knee prostheses. , 1989, Journal of biomechanics.

[33]  V. Mow,et al.  Curvature characteristics and congruence of the thumb carpometacarpal joint: differences between female and male joints. , 1992, Journal of biomechanics.

[34]  J. O'Connor,et al.  Can muscle co-contraction protect knee ligaments after injury or repair? , 1993, The Journal of bone and joint surgery. British volume.

[35]  J. Beltrán,et al.  Rheumatoid arthritis: MR imaging manifestations. , 1987, Radiology.

[36]  C C Glüer,et al.  Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation. , 1994, Radiology.

[37]  M L Hull,et al.  A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints. , 1998, Journal of biomechanics.

[38]  A B Zavatsky,et al.  Ligament Forces at the Knee during Isometric Quadriceps Contractions , 1993, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[39]  J. Buckwalter,et al.  Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[40]  M. Modic,et al.  Hemophilic arthropathy: assessment with MR imaging. , 1987, Radiology.

[41]  T. Fukubayashi,et al.  Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. , 1980, Clinical orthopaedics and related research.

[42]  J Wismans,et al.  A three-dimensional mathematical model of the knee-joint. , 1980, Journal of biomechanics.

[43]  H. Grootenboer,et al.  Articular contact in a three-dimensional model of the knee. , 1991, Journal of Biomechanics.

[44]  L. S. Matthews,et al.  Displacements of the menisci under joint load: an in vitro study in human knees. , 1994, Journal of biomechanics.