Virtual X-ray imaging techniques in an immersive casting simulation environment

Abstract A computer code was developed to simulate radiograph of complex casting products in a CAVETM-like environment. The simulation is based on the deterministic algorithms and ray tracing techniques. The aim of this study is to examine CAD/CAE/CAM models at the design stage, to optimize the design and inspect predicted defective regions with fast speed, good accuracy and small numerical expense. The present work discusses the algorithms for the radiography simulation of CAD/CAM model and proposes algorithmic solutions adapted from ray-box intersection algorithm and octree data structure specifically for radiographic simulation of CAE model. The stereoscopic visualization of full-size of product in the immersive casting simulation environment as well as the virtual X-ray images of castings provides an effective tool for design and evaluation of foundry processes by engineers and metallurgists.

[1]  Bjorn De Sutter,et al.  A Fast Algorithm to Calculate the Exact Radiological Path through a Pixel or Voxel Space , 1998 .

[2]  R. J. Ott,et al.  IEEE Nuclear Science Symposium , 2005 .

[3]  Brian E. Smits Efficiency Issues for Ray Tracing , 1998, J. Graphics, GPU, & Game Tools.

[4]  Il-Yeol Song,et al.  Octree-R: An Adaptive Octree for Efficient Ray Tracing , 1995, IEEE Trans. Vis. Comput. Graph..

[5]  M. Y. Niamat,et al.  FPGA implementation of the ray tracing algorithm used in the XPATCH software , 2001, Proceedings of the 44th IEEE 2001 Midwest Symposium on Circuits and Systems. MWSCAS 2001 (Cat. No.01CH37257).

[6]  Domingo Mery A new algorithm for flaw simulation in castings by superimposing projections of 3D models onto X-ray images , 2001, SCCC 2001. 21st International Conference of the Chilean Computer Science Society.

[7]  Huaxia Zhao,et al.  Fast ray-tracing technique to calculate line integral paths in voxel arrays , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[8]  B. Nafe,et al.  Identification of unknown dead bodies by X-ray image comparison of the skull using the X-ray simulation program FoXSIS. , 2001, Forensic science international.

[9]  Seon-Min Rhee,et al.  Low-Cost Telepresence for Collaborative Virtual Environments , 2007, IEEE Transactions on Visualization and Computer Graphics.

[10]  H Edwin Romeijn,et al.  Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning. , 2006, Medical physics.

[11]  C. Kang,et al.  Numerical visualization of viscosity in phase transformation forming process with controlled liquid fraction , 2004 .

[12]  Seon-Min Rhee,et al.  Multi-user Live Video in a Shared Virtual World for Enhanced Group Collaboration , 2006, Edutainment.

[13]  Domingo Mery,et al.  Simulation of defects in aluminium castings using CAD models of flaws and real X-ray images , 2005 .

[14]  Abdel Magid Hamouda,et al.  Numerical simulation of casting solidification in permanent metallic molds , 2006 .

[15]  J. Létang,et al.  Deterministic simulation of first-order scattering in virtual X-ray imaging , 2004 .

[16]  P. K. Seo,et al.  Semi-solid die casting process with three steps die system , 2004 .

[17]  Nozar Tabrizi,et al.  Algorithm optimizations and mapping scheme for interactive ray tracing on a reconfigurable architecture , 2003, Comput. Graph..

[18]  N. Freud,et al.  A hybrid approach to Simulate X-ray imaging techniques, combining Monte Carlo and deterministic algorithms , 2004, IEEE Transactions on Nuclear Science.

[19]  Kelvin Sung A DDA Octree Traversal Algorithm for Ray Tracing , 1991, Eurographics.

[20]  H. Kitaoka Computational morphology of the lung and its virtual imaging. , 2002, European journal of radiology.

[21]  Ignace Lemahieu,et al.  A fast, cache-aware algorithm for the calculation of radiological paths exploiting subword parallelism , 1999, J. Syst. Archit..

[22]  Yixin Wang,et al.  Application of an integrated CAD/CAE/CAM system for die casting dies , 2003 .

[23]  A. Diószegi,et al.  On the problems of thermal analysis of solidification , 2005 .

[24]  D. Thompson,et al.  Review of Progress in Quantitative Nondestructive Evaluation , 1982 .

[25]  Sang-Hyun Cho,et al.  The present and future application of computer simulation for casting design in Korean foundries , 2003 .

[26]  Gyuseong Cho,et al.  A computer code for the simulation of x-ray imaging systems , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[27]  Mario Botsch,et al.  Feature sensitive surface extraction from volume data , 2001, SIGGRAPH.

[28]  Zhengrong Liang,et al.  A fast ray-tracing technique for TCT and ECT studies , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[29]  Peter Shirley,et al.  An Efficient and Robust Ray-Box Intersection Algorithm , 2005, J. Graph. Tools.

[30]  Charles A. Monroe,et al.  Development of a hot tear indicator for steel castings , 2005 .

[31]  Nicolas Freud,et al.  A computer code to simulate X-ray imaging techniques , 2000 .

[32]  Carlos Ureña,et al.  An Efficient Parametric Algorithm for Octree Traversal , 2000, WSCG.

[33]  Nicolas Freud,et al.  Fast and robust ray casting algorithms for virtual X-ray imaging , 2006 .

[34]  Gerd-Rüdiger Tillack,et al.  X-ray modeling for industrial applications , 2000 .

[35]  James T. Kajiya,et al.  Ray tracing complex scenes , 1986, SIGGRAPH.

[36]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[37]  Dale M. Slone,et al.  HADES, a radiographic simulation code , 2000 .

[38]  Nicolas Pallikarakis,et al.  A software data generator for radiographic imaging investigations , 2000, IEEE Transactions on Information Technology in Biomedicine.

[39]  D Mery Flaw simulation in castings inspection by radioscopy RADIOSCOPY , 2001 .

[40]  Qingyan Xu,et al.  Numerical methods to improve the computational efficiency of solidification simulation for the investment casting process , 2006 .

[41]  H. Yoshikawa,et al.  Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy. , 2005, European journal of radiology.