Full-field optical coherence tomography apply in sphere measurements

The geometry of a spherical surface, for example that of a precision optic, is completely determined by the radius –of-curvature at one point and the deviation from the perfect spherical form at all other points of the sphere. Full-field Optical Coherence Tomography (FF-OCT) is a parallel detection OCT technique that utilizes a 2D detector array. This technique avoids mechanical scanning in imaging optics, thereby speeding up the imaging process and enhancing the quality of images. The current paper presents an FF-OCT instrument that is designed to be used in sphere measurement with the principle of multiple delays (MD) OCT to evaluate the curvature and radius of curved objects in single-shot imaging. The optimum combination of the MD principle with the FF-OCT method was evaluated, and the radius of a metal ball was measured with this method. The generated 2n-1 contour lines were obtained by using an MDE with n delays in a single en-face OCT image. This method of measurement, it engaged in the measurement accuracy of spherical and enriches the means of measurement, to make a spherical scan techniques flexible application.

[1]  Su Zhe OCT image denoising method based on multi-scale Wiener filtering , 2008 .

[2]  WangWen,et al.  ADAPTIVE MEASUREMENT METHOD BASED ON CHANGING-CURVATURE FOR UNKNOWN FREE-FORM SURFACE , 2004 .

[3]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[4]  Yulin Mei Level set method for topological optimization applying to structure, mechanism and material designs , 2004 .

[5]  Wang Ce Frequency-domain OCT Based on the Imaging Spectrometer , 2009 .

[6]  Lucian Plesea,et al.  Direct corneal elevation measurements using multiple delay en face optical coherence tomography. , 2008, Journal of biomedical optics.

[7]  Nan Yao,et al.  White light source spectral domain OCT based on partial spectrum analysis , 2009, Photonics and Optoelectronics Meetings.

[8]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[9]  Ren Zhao Calibration of phase shifter in spectral domain OCT system , 2008 .

[10]  G. Häusler,et al.  Three-dimensional sensing of rough surfaces by coherence radar. , 1992, Applied optics.

[11]  R Birngruber,et al.  [Examination of the cornea using optical coherence tomography]. , 2001, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[12]  袁小聪 Yuan Xiao-cong,et al.  Application of spectral domain optical coherence tomography to oral cavity tissue test , 2011 .

[13]  YU Dao-yin Ultrasound-enhanced OCT:Monte Carlo Simulation , 2009 .

[14]  Yao Jianquan,et al.  Application of Monte Carlo simulation technology in OCT imaging contrast , 2004 .

[15]  J C Wyant,et al.  Phase shifter calibration in phase-shifting interferometry. , 1985, Applied optics.

[16]  Li Gang,et al.  Improvement of spectral domain OCT image quality by linear interpolation and CCD response compensation , 2006 .

[17]  WangXiaoming,et al.  LEVEL SET METHOD FOR TOPOLOGICAL OPTIMIZATION APPLYING TO STRUCTURE, MECHANISM AND MATERIAL DESIGNS , 2004 .

[18]  R. Birngruber,et al.  Untersuchungen der Hornhaut mittels optischer Kohärenztomographie , 2001, Der Ophthalmologe.

[19]  Wang Xiao-mei,et al.  Mixed filtering method for OCT image denoising , 2011 .