Reconstruction of Vectorial Acoustic Sources in Time-Domain Tomography

A new theory is proposed for the reconstruction of curl-free vector field, whose divergence serves as acoustic source. The theory is applied to reconstruct vector acoustic sources from the scalar acoustic signals measured on a surface enclosing the source area. It is shown that, under certain conditions, the scalar acoustic measurements can be vectorized according to the known measurement geometry and subsequently be used to reconstruct the original vector field. Theoretically, this method extends the application domain of the existing acoustic reciprocity principle from a scalar field to a vector field, indicating that the stimulating vectorial source and the transmitted acoustic pressure vector (acoustic pressure vectorized according to certain measurement geometry) are interchangeable. Computer simulation studies were conducted to evaluate the proposed theory, and the numerical results suggest that reconstruction of a vector field using the proposed theory is not sensitive to variation in the detecting distance. The present theory may be applied to magnetoacoustic tomography with magnetic induction (MAT-MI) for reconstructing current distribution from acoustic measurements. A simulation on MAT-MI shows that, compared to existing methods, the present method can give an accurate estimation on the source current distribution and a better conductivity reconstruction.

[1]  D. Isaacson,et al.  A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays , 1999, IEEE Transactions on Biomedical Engineering.

[2]  Peter Basser,et al.  A theoretical model for magneto-acoustic imaging of bioelectric currents , 1994, IEEE Transactions on Biomedical Engineering.

[3]  Stephen J. Norton,et al.  Ultrasonic Reflectivity Imaging in Three Dimensions: Exact Inverse Scattering Solutions for Plane, Cylindrical, and Spherical Apertures , 1981, IEEE Transactions on Biomedical Engineering.

[4]  Stephen J. Norton,et al.  Tomographic Reconstruction of 2-D Vector Fields: Application to Flow Imaging , 1989 .

[5]  H. Weber,et al.  Temporal backward projection of optoacoustic pressure transients using fourier transform methods. , 2001, Physics in medicine and biology.

[6]  Ohin Kwon,et al.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm , 2002, IEEE Transactions on Biomedical Engineering.

[7]  M.R. Islam,et al.  A magneto-acoustic method for the noninvasive measurement of bioelectric currents , 1988, IEEE Transactions on Biomedical Engineering.

[8]  Roel Snieder,et al.  Extracting the Green's function of attenuating heterogeneous acoustic media from uncorrelated waves. , 2007, The Journal of the Acoustical Society of America.

[9]  Lihong V. Wang,et al.  Time reversal and its application to tomography with diffracting sources. , 2004, Physical review letters.

[10]  Stephen J. Norton Unique tomographic reconstruction of vector fields using boundary data , 1992, IEEE Trans. Image Process..

[11]  Lihong V. Wang,et al.  Effects of acoustic heterogeneity on the breast thermoacoustic tomography , 2003, SPIE BiOS.

[12]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[13]  Bradley J. Roth,et al.  The Effect of Electrical Anisotropy During Magnetoacoustic Tomography With Magnetic Induction , 2008, IEEE Transactions on Biomedical Engineering.

[14]  Minghua Xu,et al.  Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries , 2003, IEEE Transactions on Biomedical Engineering.

[15]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[16]  G Kossoff,et al.  Current opinion on safety of diagnostic ultrasound in pregnancy. , 1984, Australasian radiology.

[17]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[18]  Hans Braun,et al.  Tomographic reconstruction of vector fields , 1991, IEEE Trans. Signal Process..

[19]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[20]  H. Wen,et al.  Volumetric Hall Effect Tomography — A Feasibility Study , 1999, Ultrasonic imaging.

[21]  Qingyu Ma,et al.  Magnetoacoustic Tomography With Magnetic Induction: A Rigorous Theory , 2008, IEEE Transactions on Biomedical Engineering.

[22]  H. Griffiths Magnetic induction tomography , 2001 .

[23]  G. Haar,et al.  Safety of diagnostic ultrasound , 1996 .

[24]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue , 2006 .

[25]  Yuan Xu,et al.  Effects of acoustic heterogeneity in breast thermoacoustic tomography , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[27]  J. Shah,et al.  Hall effect imaging , 1998, IEEE Transactions on Biomedical Engineering.