2 0 1 0 J I N S T 5 P 0 9 0 0 6

NEXT is a new experiment to search for neutrinoless double beta decay using a 100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires excellent energy resolution, which can be achieved in a Xe TPC with electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good candidates for the scintillation readout. The performance of this photomultiplier, used as VUV photosensor in a gas proportional scintillation counter, was investigated. Initial results for the detection of primary and secondary scintillation produced as a result of the interaction of 5.9 keV X-rays in gaseous xenon, at room temperature and at pressures up to 3 bar, are presented. An energy resolution of 8.0% was obtained for secondary scintillation produced by 5.9 keV X-rays. No significant variation of the primary scintillation was observed for different pressures (1, 2 and 3 bar) and for electric fields up to 0.8 V cm−1 torr−1 in the drift region, demonstrating negligible recombination luminescence. A primary scintillation yield of 81 ± 7 photons was obtained for 5.9 keV X-rays, corresponding to a mean energy of 72± 6 eV to produce a primary scintillation photon in xenon.

[1]  T. Lux,et al.  Secondary scintillation yield in high-pressure xenon gas for neutrinoless double beta decay (0νββ) search , 2010 .

[2]  C. Winant,et al.  Constraints on inelastic dark matter from XENON10 , 2009, 0910.3698.

[3]  C. Conde,et al.  Absolute primary scintillation yield of gaseous xenon under low drift electric fields for 5.9 keV X-rays , 2008 .

[4]  D. Nygren Optimal detectors for WIMP and 0-ν ββ searches : Identical high-pressure xenon gas TPCs? , 2007 .

[5]  C. Winant,et al.  First results from the XENON10 dark matter experiment at the Gran Sasso National Laboratory. , 2007, Physical review letters.

[6]  K. Giboni,et al.  Secondary scintillation yield in pure xenon , 2007, physics/0702142.

[7]  C. Conde,et al.  Development of portable gas proportional scintillation counters for x-ray spectrometry , 2001 .

[8]  C. Conde,et al.  Full-energy absorption of x-ray energies near the Xe L- and K-photoionization thresholds in xenon gas detectors: Simulation and experimental results , 1997 .

[9]  C. Conde,et al.  A simple, inexpensive gas proportional scintillation counter for X-ray fluorescence analysis , 1993 .

[10]  Bernard Sadoulet,et al.  High pressure gas scintillation drift chambers with wave-shifter fiber readout , 1989 .

[11]  A. Peacock,et al.  Performance characteristics of a gas scintillation spectrometer for X-ray astronomy , 1980 .

[12]  A.J.P.L. Policarpo,et al.  A gas proportional scintillation counter , 1967 .

[13]  E. G. Myers,et al.  Mass and double-beta-decay Q value of 136Xe. , 2007, Physical review letters.