Improving SNR and B1 transmit field for an endorectal coil in 7 T MRI and MRS of prostate cancer

Higher magnetic field strengths like 7 T and above are desirable for MR spectroscopy given the increased spectral resolution and signal to noise ratio. At these field strengths, substantial nonuniformities in B1+/− and radiofrequency power deposition become apparent. In this investigation, we propose an improvement on a conventionally used endorectal coil, through the addition of a second element (stripline). Both elements are used as transceivers. In the center of the prostate, approximately 40% signal to noise ratio increase is achieved. In fact, the signal to noise ratio gain obtained with the quadrature configuration locally can be even greater than 40% when compared to the single loop configuration. This is due to the natural asymmetry of the B1+/− fields at high frequencies, which causes destructive and constructive interference patterns. Global specific absorption rate is reduced by almost a factor of 2 as expected. Furthermore, approximately a 4‐fold decrease in local specific absorption rate is observed when normalized to the B1 values in the center of the prostate. Because of the 4‐fold local specific absorption rate decrease obtained with the dual channel setup for the same reference B1 value (20 μT at 3.5 cm depth into the prostate) as compared to the single loop, the transmission power B1 duty cycle can be increased by a factor 4. Consequently, when using the two‐element endorectal coil, the radiofrequency power deposition is significantly reduced and radiofrequency intense sequences with adiabatic pulses can be safely applied at 7 T for 1H magnetic resonance spectroscopy and MRI in the prostate. Altogether, in vivo 1H magnetic resonance spectroscopic imaging of prostate cancer with a fully adiabatic sequence operated at a minimum B1+ of 20 μT shows insensitivity to the nonuniform transmit field, while remaining within local specific absorption rate guidelines of 10 W/kg. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

[1]  A. Heerschap,et al.  Proton spectroscopic imaging of the human prostate at 7 T , 2009, NMR in biomedicine.

[2]  David G. Norris,et al.  Adiabatic radiofrequency pulse forms in biomedical nuclear magnetic resonance , 2002 .

[3]  Klaas Nicolay,et al.  Adiabatic rf pulses: applications to in vivo NMR , 1997 .

[4]  Tristan Barrett,et al.  Dynamic contrast-enhanced MRI of prostate cancer at 3 T: a study of pharmacokinetic parameters. , 2007, AJR. American journal of roentgenology.

[5]  MEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTS , 2004, Health physics.

[6]  Takeo Ishigaki,et al.  Differentiation of noncancerous tissue and cancer lesions by apparent diffusion coefficient values in transition and peripheral zones of the prostate , 2005, Journal of magnetic resonance imaging : JMRI.

[7]  K. Hosseinzadeh,et al.  Endorectal diffusion‐weighted imaging in prostate cancer to differentiate malignant and benign peripheral zone tissue , 2004, Journal of magnetic resonance imaging : JMRI.

[8]  K. Pruessmann,et al.  B  1+ interferometry for the calibration of RF transmitter arrays , 2009, Magnetic resonance in medicine.

[9]  R. Bartha,et al.  High‐field MRSI of the prostate using a transmit/receive endorectal coil and gradient modulated adiabatic localization , 2009, Journal of magnetic resonance imaging : JMRI.

[10]  Arend Heerschap,et al.  Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[11]  M. Garwood,et al.  Adiabatic pulses , 1997, NMR in biomedicine.

[12]  Arend Heerschap,et al.  Proton MR spectroscopy of prostatic tissue focused on the etection of spermine, a possible biomarker of malignant behavior in prostate cancer , 2000, Magnetic Resonance Materials in Physics, Biology and Medicine.

[13]  B. Issa,et al.  In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo‐planar imaging , 2002, Journal of magnetic resonance imaging : JMRI.

[14]  Ergin Atalar,et al.  Design of internal MRI coils using ultimate intrinsic SNR , 2009, Magnetic Resonance Materials in Physics, Biology and Medicine.

[15]  T. Scheenen,et al.  Detection of fully refocused polyamine spins in prostate cancer at 7 T , 2011, NMR in biomedicine.

[16]  Silvia D. Chang,et al.  Combined diffusion‐weighted and dynamic contrast‐enhanced MRI for prostate cancer diagnosis—Correlation with biopsy and histopathology , 2006, Journal of magnetic resonance imaging : JMRI.

[17]  Peter Andersen,et al.  9.4T human MRI: Preliminary results , 2006, Magnetic resonance in medicine.

[18]  Peter Andersen,et al.  Whole‐body imaging at 7T: Preliminary results , 2009, Magnetic resonance in medicine.

[19]  R. Bartha,et al.  Reduced power magnetic resonance spectroscopic imaging of the prostate at 4.0 Tesla , 2009, Magnetic resonance in medicine.

[20]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[21]  K Ugurbil,et al.  In vivo 1H NMR spectroscopy of the human brain at 7 T , 2001, Magnetic resonance in medicine.

[22]  G. Metzger,et al.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurements , 2008, Magnetic resonance in medicine.

[23]  D. Hoult Sensitivity and Power Deposition in a High‐Field Imaging Experiment , 2000, Journal of magnetic resonance imaging : JMRI.

[24]  B. Beck,et al.  Tissue‐equivalent phantoms for high frequencies , 2004 .

[25]  A. Sbarbati,et al.  Evolution strategy optimization for adiabatic pulses in MRI. , 1999, Journal of magnetic resonance.

[26]  Michael Garwood,et al.  Solvent Suppression Using Selective Echo Dephasing , 1996 .

[27]  J. Lagendijk,et al.  Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil , 2010, NMR in biomedicine.