Improving Echo-Guided Procedures Using an Ultrasound-CT Image Fusion System

Introduction. Image fusion between ultrasound (US) and computed tomography (CT) scan or magnetic resonance can increase operator accuracy in targeting liver lesions, particularly when those are undetectable with US alone. We have developed a modular gel to simulate hepatic solid lesions for educational purposes in imaging and minimally invasive ablation techniques. We aimed to assess the impact of image fusion in targeting artificial hepatic lesions during the hands-on part of 2 courses (basic and advanced) in hepatobiliary surgery. Materials and methods. Under US guidance, 10 fake tumors of various sizes were created in the livers of 2 pigs, by percutaneous injection of a biocompatible gel engineered to be hyperdense on CT scanning and barely detectable on US. A CT scan was obtained and a CT-US image fusion was performed using the ACUSON S3000 US system (Siemens Healthcare, Germany). A total of 12 blinded course attendants, were asked in turn to perform a 10-minute liver scan with US alone followed by a 10-minute scan using image fusion. Results. Using US alone, the expert managed to identify all lesions successfully. The true positive rate for course attendants with US alone was 14/36 and 2/24 in the advanced and basic courses, respectively. The total number of false positives identified was 26. With image fusion, the rate of true positives significantly increased to 31/36 (P < .001) in the advanced group and 16/24 in the basic group (P < .001). The total number of false positives, considering all participants, decreased to 4 (P < .001). Conclusions. Image fusion significantly increases accuracy in targeting hepatic lesions and might improve echo-guided procedures.

[1]  Electrolytic ablation is as effective as radiofrequency ablation in the treatment of artificial liver metastases in a pig model , 2008, Journal of surgical oncology.

[2]  Daniel B. Jones,et al.  Development of an in vivo tumor-mimic model for learning radiofrequency ablation , 2000, Journal of Gastrointestinal Surgery.

[3]  M. Choti,et al.  Development of hepatic pseudotumors for image-guided interventional and surgical research in a large animal model. , 2011, Journal of vascular and interventional radiology : JVIR.

[4]  Thomas Langø,et al.  Development of a Multimodal Tumor Model for Porcine Liver , 2010, Journal of Gastrointestinal Surgery.

[5]  S. Nahum Goldberg,et al.  Real-Time US-CT/MRI Image Fusion for Guidance of Thermal Ablation of Liver Tumors Undetectable with US: Results in 295 Cases , 2015, CardioVascular and Interventional Radiology.

[6]  Li-Da Chen,et al.  Percutaneous radiofrequency ablation of malignant liver tumors with ultrasound and CT fusion imaging guidance , 2014, Journal of clinical ultrasound : JCU.

[7]  H. Bruch,et al.  Development of a perfused ex vivo tumor-mimic model for the training of laparoscopic radiofrequency ablation , 2007, Surgical Endoscopy.

[8]  I. Cuthill,et al.  Improving Bioscience Research Reporting: The ARRIVE Guidelines for Reporting Animal Research † , 2012, Osteoarthritis and cartilage.

[9]  W. A. N'Djin,et al.  A Tumor-mimic Model for Evaluating the Accuracy of HIFU Preclinical Studies: An In Vivo Study , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  P M Paprottka,et al.  Image fusion in the management of thermal tumor ablation of the liver. , 2012, Clinical hemorheology and microcirculation.