Linearity dependence on oxygen fraction and gas temperature of a novel Fleisch pneumotachograph for neonatal ventilation at low flow rates

Abstract Fleisch pneumotachograph response is influenced by gas composition and temperature. Literature analysis shows that the influence of gas properties on the relationship between pressure drop and volumetric flow rate has not been widely investigated from the theoretical standpoint. We fit data reported in literature by multiple linear regression, with the aim to obtain an equation in which the dynamic viscosity of a gas mixture, mainly composed by nitrogen and oxygen, is directly related with gas temperature and oxygen fraction. A low dead space (2 mL) Fleisch pneumotachograph was designed and realized for neonatal ventilation, with linear range from −4 L min −1 to +4 L min −1 . The theoretical model, considering gas dynamic viscosity dependence on temperature and oxygen fraction, is presented and experimentally validated by varying gas temperature (299–310 K) and oxygen fraction (21–100%) within the limit conditions for the specific application. Oxygen fraction resulted the most influent factor on gas viscosity and, therefore, on the pneumotachograph response. In the worst case, the maximum variation of gas oxygen fraction produced a measurement shift of about 1 L min −1 , i.e., the 25% of full scale output. The introduction of a correction based on the proposed model allows to reduce the linearity shift, becoming lower than 6%, and may also reduce the need of frequent calibrations due to gas composition and temperature changes.

[1]  S. Cecchini,et al.  Proportional mechanical ventilation through PWM driven on/off solenoid valve , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[2]  Anna Gina Perri,et al.  A New System for Continuous Monitoring of Breathing and Kinetic Activity , 2010, J. Sensors.

[3]  R. Gardner,et al.  Effect of O2, N2, and CO2 composition on nonlinearity of Fleisch pneumotachograph characteristics. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.

[4]  A. Lay-Ekuakille,et al.  Spirometric Measurement Postprocessing: Expiration Data Recovery , 2010, IEEE Sensors Journal.

[5]  Huibert Burger,et al.  Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometers , 2003, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[6]  J E Cotes,et al.  Lung volumes and forced ventilatory flows , 1993, European Respiratory Journal.

[7]  S. Silvestri,et al.  Influence of gas temperature on the performances of a low dead space capillary type pneumotachograph for neonatal ventilation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  J E Cotes,et al.  Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. , 1993, The European respiratory journal. Supplement.

[9]  Air features in spirometric transducers , 2006 .

[10]  Myer Kutz,et al.  Standard Handbook of Biomedical Engineering and Design , 2002 .

[11]  W. A. Cole,et al.  The viscosity of nitrogen, oxygen, and their binary mixtures in the limit of zero density , 1985 .

[12]  A. Rothberg,et al.  Calibration of Fleisch and screen pneumotachographs for use with various oxygen concentrations , 1990, Medical and Biological Engineering and Computing.

[13]  A. Rothberg,et al.  Effects of temperature and composition on the viscosity of respiratory gases. , 1989, Journal of applied physiology.

[14]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[15]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .