Self-Alignment Mechanisms for Assistive Wearable Robots: A Kinetostatic Compatibility Method

The field of wearable robotics is gaining momentum thanks to its potential application in rehabilitation engineering, assistive robotics, and power augmentation. These devices are designed to be used in direct contact with the user to aid with movement or increase the power of specific skeletal joints. The design of the so-called physical human-robot interface is critical, since it determines not only the efficacy of the robot but the kinematic compatibility of the device with the human skeleton and the degree of adaptation to different anthropometries as well. Failing to deal with these problems causes misalignments between the robot and the user joint. Axes misalignment leads to the impossibility of controlling the torque effectively transmitted to the user joint and causes undesired loading forces on articulations and soft tissues. In this paper, we propose a general analytical method for the design of exoskeletons able to assist human joints without being subjected to misalignment effects. This method is based on a kinetostatic analysis of a coupled mechanism (robot-human skeleton) and can be applied in the design of self-aligning mechanisms. The method is exemplified in the design of an assistive robotic chain for a two-degree-of-freedom (DOF) human articulation.

[1]  Massimo Bergamasco,et al.  An arm exoskeleton system for teleoperation and virtual environments applications , 1994, Proceedings of the 1994 IEEE International Conference on Robotics and Automation.

[2]  Michel Benoit,et al.  MoonWalker, a lower limb exoskeleton able to sustain bodyweight using a passive force balancer , 2010, 2010 IEEE International Conference on Robotics and Automation.

[3]  S.J. Ball,et al.  MEDARM: a rehabilitation robot with 5DOF at the shoulder complex , 2007, 2007 IEEE/ASME international conference on advanced intelligent mechatronics.

[4]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.

[5]  David J. Reinkensmeyer,et al.  Optimization of a Parallel Shoulder Mechanism to Achieve a High-Force, Low-Mass, Robotic-Arm Exoskeleton , 2010, IEEE Transactions on Robotics.

[6]  M. Goldfarb,et al.  Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[7]  Sunil Kumar Agrawal,et al.  Gravity-Balancing Leg Orthosis and Its Performance Evaluation , 2006, IEEE Transactions on Robotics.

[8]  Nikolaos G. Tsagarakis,et al.  Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training , 2003, Auton. Robots.

[9]  M. Morari,et al.  Robotic Orthosis Lokomat: A Rehabilitation and Research Tool , 2003, Neuromodulation : journal of the International Neuromodulation Society.

[10]  Frans C. T. van der Helm,et al.  Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations , 2009, IEEE Transactions on Robotics.

[11]  J. Landaluze,et al.  Design of a five actuated DoF upper limb exoskeleton oriented to workplace help , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[12]  J. Edward Colgate,et al.  Design of an active one-degree-of-freedom lower-limb exoskeleton with inertia compensation , 2011, Int. J. Robotics Res..

[13]  Joseph Hidler,et al.  Limb Alignment and Kinematics Inside a Lokomat Robotic Orthosis , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Jerry E. Pratt,et al.  The RoboKnee: an exoskeleton for enhancing strength and endurance during walking , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[15]  James A. Johnson,et al.  Variability and repeatability of the flexion axis at the ulnohumeral joint , 2003, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[16]  Frans C. T. van der Helm,et al.  A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots , 2006, Int. J. Robotics Res..

[17]  Elizabeth A. Brackbill,et al.  Dynamics and control of a 4-dof wearable cable-driven upper arm exoskeleton , 2009, 2009 IEEE International Conference on Robotics and Automation.

[18]  Michael A. Peshkin,et al.  A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke , 2009, IEEE Transactions on Robotics.

[19]  C. Carignan,et al.  Design of an arm exoskeleton with scapula motion for shoulder rehabilitation , 2005, ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005..

[20]  F.C.T. van der Helm,et al.  Kinematic Design to Improve Ergonomics in Human Machine Interaction , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[21]  E. Rocon,et al.  Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[22]  Clément Gosselin,et al.  Kinetostatic analysis of underactuated fingers , 2004, IEEE Transactions on Robotics and Automation.

[23]  M. Levin,et al.  What Do Motor “Recovery” and “Compensation” Mean in Patients Following Stroke? , 2009, Neurorehabilitation and neural repair.

[24]  T. Brown,et al.  Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  P. Feys,et al.  The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis: a pilot study , 2011, Journal of NeuroEngineering and Rehabilitation.

[26]  Yoshiyuki Sankai,et al.  Development of single leg version of HAL for hemiplegia , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[27]  Aaron M. Dollar,et al.  Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art , 2008, IEEE Transactions on Robotics.

[28]  Bruno Siciliano,et al.  Control Problems in Robotics and Automation , 1998 .

[29]  Lihua Huang,et al.  Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX) , 2006, Int. J. Robotics Res..

[30]  Guillaume Morel,et al.  Connecting a Human Limb to an Exoskeleton , 2012, IEEE Transactions on Robotics.

[31]  J.C. Perry,et al.  Upper-Limb Powered Exoskeleton Design , 2007, IEEE/ASME Transactions on Mechatronics.

[32]  Francesco Giovacchini,et al.  Mechatronic Design and Characterization of the Index Finger Module of a Hand Exoskeleton for Post-Stroke Rehabilitation , 2012, IEEE/ASME Transactions on Mechatronics.

[33]  Marcia Kilchenman O'Malley,et al.  Design, Control and Performance of RiceWrist: A Force Feedback Wrist Exoskeleton for Rehabilitation and Training , 2008, Int. J. Robotics Res..

[34]  Ken Endo,et al.  A Quasi-Passive Leg Exoskeleton for Load-Carrying Augmentation , 2007, Int. J. Humanoid Robotics.

[35]  Nikolaos G. Tsagarakis,et al.  A human hand compatible optimised exoskeleton system , 2010, 2010 IEEE International Conference on Robotics and Biomimetics.

[36]  M. Bergamasco,et al.  Arm rehabilitation with a robotic exoskeleleton in Virtual Reality , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[37]  Jose L Pons,et al.  Rehabilitation Exoskeletal Robotics , 2010, IEEE Engineering in Medicine and Biology Magazine.

[38]  Robert Riener,et al.  ARMin II - 7 DoF rehabilitation robot: mechanics and kinematics , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.