Post-earthquake continuous dynamic monitoring of the Gabbia Tower in Mantua, Italy

Abstract The Gabbia Tower , about 54.0 m high and dating back to the XIII century, is the tallest tower in Mantua, overlooking the historic centre listed within the UNESCO Heritage. After the seismic sequence of May 2012 in Italy, an extensive research program was carried out to assess the structural condition of the tower. The post-earthquake investigation (including direct survey, historic and documentary research, testing of materials and ambient vibration tests) highlighted the poor state of preservation of the upper part of the building and suggested the installation of a dynamic monitoring system to evaluate the response of the tower to the expected sequence of far-field earthquakes and check the possible evolution of the structural behavior. After a brief description of the tower and the post-earthquake survey, the paper presents the results of the continuous dynamic monitoring for a period of 8 months, highlighting the effect of temperature on automatically identified natural frequencies, the practical feasibility of damage detection methods based on natural frequencies shifts and the key role of permanent dynamic monitoring in the diagnosis of the investigated historic building.

[1]  Reto Cantieni One-Year Monitoring of a Historic Bell Tower , 2014 .

[2]  Alessandro Cabboi Automatic operational modal analysis: challenges and applications to historic structures and infrastructures , 2014 .

[3]  Palle Andersen,et al.  Modal Identification from Ambient Responses using Frequency Domain Decomposition , 2000 .

[4]  T. O. Kvålseth Cautionary Note about R 2 , 1985 .

[5]  A. Pau,et al.  Vibration analysis and dynamic characterization of the Colosseum , 2008 .

[6]  Paulo B. Lourenço,et al.  Monitoring historical masonry structures with operational modal analysis: Two case studies , 2007 .

[7]  Filipe Magalhães,et al.  Explaining operational modal analysis with data from an arch bridge , 2011 .

[8]  Walter Salvatore,et al.  Dynamic Behavior of a Medieval Masonry Bell Tower. II: Measurement and Modeling of the Tower Motion , 2005 .

[9]  Salvador Ivorra,et al.  Dynamic investigations on a masonry bell tower , 2006 .

[10]  Claudio Modena,et al.  Seismic Assessment of Complex Historical Buildings: Application to Reggio Emilia Cathedral, Italy , 2008 .

[11]  Antonella Saisi,et al.  Post-earthquake diagnostic investigation of a historic masonry tower , 2015 .

[12]  Paulo B. Lourenço,et al.  Numerical models for the seismic assessment of an old masonry tower , 2010 .

[13]  Carmelo Gentile,et al.  Ambient vibration testing of historic masonry towers for structural identification and damage assessment , 2007 .

[14]  Alessandro Cabboi,et al.  Structural Identification of a Masonry Tower Based on Operational Modal Analysis , 2015 .

[15]  Diego González-Aguilera,et al.  The combination of geomatic approaches and operational modal analysis to improve calibration of finite element models: A case of study in Saint Torcato Church (Guimarães, Portugal) , 2014 .

[16]  Carmelo Gentile,et al.  Operational modal testing of historic structures at different levels of excitation , 2013 .

[17]  Guido De Roeck,et al.  Fully automated (operational) modal analysis , 2012 .

[18]  Guido De Roeck,et al.  REFERENCE-BASED STOCHASTIC SUBSPACE IDENTIFICATION FOR OUTPUT-ONLY MODAL ANALYSIS , 1999 .

[19]  Fuat Aras,et al.  Experimental and numerical modal analyses of a historical masonry palace , 2011 .

[20]  Wei-Xin Ren,et al.  Dynamic and seismic performance of old multi-tiered temples in Nepal , 2003 .

[21]  Carlos Sousa Oliveira,et al.  Minaret behavior under earthquake loading: The case of historical Istanbul , 2012 .